Aortoiliac and Renal Arteries: Prospective Intraindividual Comparison of Contrast-enhanced Three-dimensional MR Angiography and Multi–Detector Row CT Angiography
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
PURPOSE: To compare contrast material-enhanced three-dimensional (3D) magnetic resonance (MR) angiography and multi-detector row computed tomographic (CT) angiography in the same patients for assessment of the aortoiliac and renal arteries, with digital subtraction angiography (DSA) as the standard of reference. MATERIALS AND METHODS: DSA, 3D MR angiography, and multi-detector row CT angiography were performed in 46 consecutive patients. A total of 769 arterial segments were analyzed for arterial stenosis by using a four-point grading system. Aneurysmal changes were noted. The time required for performing 3D reconstructions and image analysis of both MR and CT data sets was measured. Patient acceptance for each modality was assessed with a visual analogue scale. Statistical analysis of data was performed. RESULTS: Sensitivity of MR angiography for detection of hemodynamically significant arterial stenosis was 92% for reader 1 and 93% for reader 2, and specificity was 100% and 99%, respectively. Sensitivity of CT angiography was 91% for reader 1 and 92% for reader 2, and specificity was 99% and 99%, respectively. Differences between the two modalities were not significant. Interobserver and intermodality agreement was excellent (kappa = 0.88-0.90). The time for performance of 3D reconstruction and image analysis of CT data sets was significantly longer than that for MR data sets (P <.001). Patient acceptance was best for CT angiography (P =.016). CONCLUSION: There is no statistically significant difference between 3D MR angiography and multi-detector row CT angiography in the detection of hemodynamically significant arterial stenosis of the aortoiliac and renal arteries.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529786 · Cited by 4,332
Dynamic gadolinium‐enhanced three‐dimensional abdominal MR arteriography
Prince, M. R., Yucel, E. K., Kaufman, J. A., Harrison, D. C., & Geller, S. C. (1993) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880030614 · Cited by 499
Arteriographic complications in the DSA era.
Waugh, J. R., & Sacharias, N. (1992) · Radiology · doi:10.1148/radiology.182.1.1727290 · Cited by 469
Three-dimensional spiral CT angiography of the abdomen: initial clinical experience.
Rubin, G. D., Dake, M. D., Napel, S. A., McDonnell, C. H., & Jeffrey, R. B. (1993) · Radiology · doi:10.1148/radiology.186.1.8416556 · Cited by 362
Atherosclerosis and arteriosclerosis in chronic renal failure
London, G. M., & Drüeke, T. B. (1997) · Kidney International · doi:10.1038/ki.1997.233 · Cited by 354
Multi–Detector Row CT Angiography of Lower Extremity Arterial Inflow and Runoff: Initial Experience
Rubin, G. D., Schmidt, A. J., Logan, L. J., & Sofilos, M. C. (2001) · Radiology · doi:10.1148/radiol.2211001325 · Cited by 302
Aorta and Iliac Arteries: Single versus Multiple Detector-Row Helical CT Angiography
Rubin, G. D., Shiau, M. C., Leung, A. N., Kee, S. T., Logan, L. J., & Sofilos, M. C. (2000) · Radiology · doi:10.1148/radiology.215.3.r00jn18670 · Cited by 248
Breath-hold, contrast-enhanced, three-dimensional MR angiography.
Leung, D. A., McKinnon, G. C., Davis, C. P., Pfammatter, T., Krestin, G. P., & Debatin, J. F. (1996) · Radiology · doi:10.1148/radiology.200.2.8685359 · Cited by 220
Self-citationData explosion: the challenge of multidetector-row CT
Rubin, G. D. (2000) · European Journal of Radiology · doi:10.1016/s0720-048x(00)00270-9 · Cited by 208
APPLICATION OF VISUAL-ANALOGUE SCALES TO THE MEASUREMENT OF FUNCTIONAL CAPACITY
HUSKISSON, E. C., JONES, J., & SCOTT, P. J. (1976) · Rheumatology · doi:10.1093/rheumatology/15.3.185 · Cited by 191
Ruehm, S. G., Hany, T. F., Pfammatter, T., Schneider, E., Ladd, M., & Debatin, J. F. (2000) · American Journal of Roentgenology · doi:10.2214/ajr.174.4.1741127 · Cited by 177
Self-citationJohnson, P. T., Halpern, E. J., Kuszyk, B. S., et al. (1999) · Radiology · doi:10.1148/radiology.211.2.r99ap17337 · Cited by 152
Helical CT angiography compared with arteriography in the detection of renal artery stenosis.
Bérégi, J.-P., Elkohen, M., Deklunder, G., Artaud, D., Coullet, J.-M., & Wattinne, L. (1996) · American Journal of Roentgenology · doi:10.2214/ajr.167.2.8686635 · Cited by 131
Magnetic Resonance Angiography Versus Duplex Sonography for Diagnosing Renovascular Disease
Leung, D. A., Hoffmann, U., Pfammatter, T., Hany, T. F., Rainoni, L., Hilfiker, P., Schneider, E., Zimmermann-Paul, G. G., & Debatin, J. F. (1999) · Hypertension · doi:10.1161/01.hyp.33.2.726 · Cited by 112
Self-citationNoninvasive Imaging of Living Related Kidney Donors
Rankin, S., Jan, W., & Koffman, C. G. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.2.1770349 · Cited by 103
Preoperative Evaluation of Living Renal Donors: Comparison of CT Angiography and MR Angiography
Halpern, E. J., Mitchell, D. G., Wechsler, R. J., Outwater, E. K., Moritz, M. J., & Wilson, G. A. (2000) · Radiology · doi:10.1148/radiology.216.2.r00au25434 · Cited by 97
Kaufman, J. A., Geller, S. C., Petersen, M. J., Cambria, R. P., Prince, M. R., & Waltman, A. C. (1994) · American Journal of Roentgenology · doi:10.2214/ajr.163.1.8010215 · Cited by 73
Horton, K. M., & Fishman, E. K. (2000) · Abdominal Imaging · doi:10.1007/s002610000050 · Cited by 69
Cost Identification of Abdominal Aortic Aneurysm Imaging by Using Time and Motion Analyses
Rubin, G. D., Armerding, M. D., Dake, M. D., & Napel, S. A. (2000) · Radiology · doi:10.1148/radiology.215.1.r00ap4863 · Cited by 45
Masutani, Y., MacMahon, H., & Doi, K. (2001) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200107000-00014 · Cited by 24
Cited by
Hirsch, A. T., Haskal, Z. J., Hertzer, N. R., Bakal, C. W., Creager, M. A., Halperin, J. L., Hiratzka, L. F., Murphy, W. R. C., Olin, J. W., Puschett, J. B., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.174526 · Cited by 3,708
Hirsch, A. T., Haskal, Z. J., Hertzer, N. R., Bakal, C. W., Creager, M. A., Halperin, J. L., Hiratzka, L. F., Murphy, W. R. C., Olin, J. W., Puschett, J. B., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.10.009 · Cited by 1,021
(2006) · Circulation · doi:10.1161/circulationaha.106.173994 · Cited by 201
Schnorr, J., Wagner, S., Abramjuk, C., Wojner, I., Schink, T., Kroencke, T. J., Schellenberger, E., Hamm, B., Pilgrimm, H., & Taupitz, M. (2004) · Investigative Radiology · doi:10.1097/01.rli.0000133944.30119.cc · Cited by 54
Metadata
- Authors
- Willmann, J. K., Wildermuth, S., Pfammatter, T., Roos, J. E., Seifert, B., Hilfiker, P. R., Marincek, B., & Weishaupt, D.
- Venue
- Radiology
- Published
- 2003-03
- Volume
- 226
- Issue
- 3
- Pages
- 798-811
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2141327062
- Cited by
- 197
- References
- 20
- FWCI
- 22.25
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.