MR Procedures: Biologic Effects, Safety, and Patient Care
The DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Abstract
The technology used for magnetic resonance (MR) procedures has evolved continuously during the past 20 years, yielding MR systems with stronger static magnetic fields, faster and stronger gradient magnetic fields, and more powerful radiofrequency transmission coils. Most reported cases of MR-related injuries and the few fatalities that have occurred have apparently been the result of failure to follow safety guidelines or of use of inappropriate or outdated information related to the safety aspects of biomedical implants and devices. To prevent accidents in the MR environment, therefore, it is necessary to revise information on biologic effects and safety according to changes that have occurred in MR technology and with regard to current guidelines for biomedical implants and devices. This review provides an overview of and update on MR biologic effects, discusses new or controversial MR safety topics and issues, presents evidence-based guidelines to ensure safety for patients and staff, and describes safety information for various implants and devices that have recently undergone evaluation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
International Electrotechnical Commission
Buck, J. (2010) · Handbook of Transnational Economic Governance Regimes · doi:10.1163/ej.9789004163300.i-1081.494 · Cited by 2,742
Electrical Stimulation of the Subthalamic Nucleus in Advanced Parkinson's Disease
Limousin, P., Krack, P., Pollak, P., Benazzouz, A., Ardouin, C., Hoffmann, D., & Benabid, A.-L. (1998) · New England Journal of Medicine · doi:10.1056/nejm199810153391603 · Cited by 1,853
Safety of Strong, Static Magnetic Fields
Schenck, J. F. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200007)12:1<2::aid-jmri2>3.0.co;2-v · Cited by 436
Magnetic resonance imaging and cardiac pacemaker safety at 1.5-Tesla
Martin, E. T., Coman, J. A., Shellock, F. G., Pulling, C. C., Fair, R., & Jenkins, K. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.12.016 · Cited by 422
Self-citationRadiofrequency Energy-Induced Heating During MR Procedures: A Review
Shellock, F. G. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200007)12:1<30::aid-jmri4>3.0.co;2-s · Cited by 343
Self-citationRezai, A. R., Finelli, D., Nyenhuis, J. A., Hrdlicka, G., Tkach, J., Sharan, A., Rugieri, P., Stypulkowski, P. H., & Shellock, F. G. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10069 · Cited by 285
Self-citationAmerican College of Radiology White Paper on MR Safety
Kanal, E., Borgstede, J. P., Barkovich, A. J., Bell, C., Bradley, W. G., Felmlee, J. P., Froelich, J. W., Kaminski, E. M., Keeler, E. K., Lester, J. W., et al. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.178.6.1781335 · Cited by 282
Cardiovascular aspects of human thermoregulation.
Rowell, L. B. (1983) · Circulation Research · doi:10.1161/01.res.52.4.367 · Cited by 276
Review of Patient Safety in Time-Varying Gradient Fields
Schaefer, D. J., Bourland, J. D., & Nyenhuis, J. A. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200007)12:1<20::aid-jmri3>3.0.co;2-y · Cited by 254
Effects of magnetic resonance imaging on cardiac pacemakers and electrodes
Achenbach, S. S., Moshage, W. E. L., Diem, B., Bieberlea, T., Schibgilla, V., & Bachmann, K. F. (1997) · American Heart Journal · doi:10.1016/s0002-8703(97)70083-8 · Cited by 254
Cited by
ESC Guidelines on the management of cardiovascular diseases during pregnancy
Endorsed by the European Society of Gynecology (ESG), T. A. F. E. P. C. (., Authors/Task Force Members, Regitz-Zagrosek, V., Blomstrom Lundqvist, C., Borghi, C., Cifkova, R., Ferreira, R., Foidart, J.-M., Gibbs, J. S. R., Gohlke-Baerwolf, C., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehr218 · Cited by 1,924
Cellular Cargo Delivery: Toward Assisted Fertilization by Sperm-Carrying Micromotors
Medina-Sánchez, M., Schwarz, L., Meyer, A. K., Hebenstreit, F., & Schmidt, O. G. (2016) · Nano Letters · doi:10.1021/acs.nanolett.5b04221 · Cited by 553
Levine, G. N., Gomes, A. S., Arai, A. E., Bluemke, D. A., Flamm, S. D., Kanal, E., Manning, W. J., Martin, E. T., Smith, J. M., Wilke, N., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.187256 · Cited by 489
Self-citationThe Role of Cardiovascular Magnetic Resonance Imaging in Heart Failure
Karamitsos, T. D., Francis, J. M., Myerson, S., Selvanayagam, J. B., & Neubauer, S. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.04.094 · Cited by 467
Patel, S. J., Reede, D. L., Katz, D. S., Subramaniam, R., & Amorosa, J. K. (2007) · RadioGraphics · doi:10.1148/rg.276075002 · Cited by 460
GUIDELINES ON LIMITS OF EXPOSURE TO STATIC MAGNETIC FIELDS
(2009) · Health Physics · doi:10.1097/01.hp.0000343164.27920.4a · Cited by 455
Real-time fMRI neurofeedback: Progress and challenges
Sulzer, J., Haller, S., Scharnowski, F., Weiskopf, N., Birbaumer, N., Blefari, M. L., Bruehl, A. B., Cohen, L. G., deCharms, R. C., Gassert, R., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.03.033 · Cited by 453
“In over 20 years of application, no severe adverse events have occurred or side effects have been detected as long as safety guidelines are followed (Bourland et al., 1999; Schaefer et al., 2000; Schenck, 2000; Shellock and Crues, 2004).”
BackgroundNazarian, S., Roguin, A., Zviman, M. M., Lardo, A. C., Dickfeld, T. L., Calkins, H., Weiss, R. G., Berger, R. D., Bluemke, D. A., & Halperin, H. R. (2006) · Circulation · doi:10.1161/circulationaha.105.607655 · Cited by 356
Contraindications to magnetic resonance imaging
Dill, T. (2008) · Heart · doi:10.1136/hrt.2007.125039 · Cited by 239
“If possible cosmetics should be removed before scanning. The same holds true for piercing material. If removal is not possible an icepack/cold compress may be used. In a review of the literature Shellock concludes that neither tattoos nor cosmetics are a contraindication for MRI, provided that appropriate precautions…”
BackgroundJanicak, P. G., O'Reardon, J. P., Sampson, S. M., Hussain, M. M., Lisanby, S. H., Rado, J. T., Heart, K. L., & Demitrack, M. A. (2008) · The Journal of Clinical Psychiatry · doi:10.4088/jcp.v69n0208 · Cited by 235
“Thus, the safety information that has been obtained from the extensive published literature on the use of pulsed magnetic fields in the context of magnetic resonance imaging technology is relevant to this issue.(42,43) In this regard, TMS utilizes a magnetic field that is clinically comparable to the pulsed gradient f…”
MethodJungmann, P. M., Agten, C. A., Pfirrmann, C. W., & Sutter, R. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25708 · Cited by 227
Magnetic resonance angiography: current status and future directions
Hartung, M. P., Grist, T. M., & François, C. J. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-19 · Cited by 213
Tsekos, N. V., Khanicheh, A., Christoforou, E., & Mavroidis, C. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.121806.160642 · Cited by 202
MRI and implanted medical devices: basic interactions with an emphasis on heating
Nyenhuis, J. A., Park, S.-M., Kamondetdacha, R., Amjad, A., Shellock, F. G., & Rezai, A. R. (2005) · IEEE Transactions on Device and Materials Reliability · doi:10.1109/tdmr.2005.859033 · Cited by 199
“[2] F. G. Shellock and J. V. Crues, “MR procedures: Biologic effects, safety and patient care,” Radiology, vol. 232, no. 3, pp. 635–652, Jul. 2004.”
BackgroundSelf-citationISUOG Practice Guidelines: performance of fetal magnetic resonance imaging
Prayer, D., Malinger, G., Brugger, P. C., Cassady, C., De Catte, L., De Keersmaecker, B., Fernandes, G. L., Glanc, P., Gonçalves, L. F., Gruber, G. M., et al. (2017) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.17412 · Cited by 191
MR Labeling Information for Implants and Devices: Explanation of Terminology
Shellock, F. G., Woods, T. O., & Crues, J. V. (2009) · Radiology · doi:10.1148/radiol.2531091030 · Cited by 181
Self-citationCasali, M., Lauri, C., Altini, C., Bertagna, F., Cassarino, G., Cistaro, A., Erba, A. P., Ferrari, C., Mainolfi, C. G., Palucci, A., et al. (2021) · Clinical and Translational Imaging · doi:10.1007/s40336-021-00445-w · Cited by 178
MRI protocols for whole-organ assessment of the knee in osteoarthritis
Peterfy, C. G., Gold, G., Eckstein, F., Cicuttini, F., Dardzinski, B., & Stevens, R. (2006) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2006.02.029 · Cited by 173
Deep brain stimulation and electromagnetic interference
Rahimpour, S., Kiyani, M., Hodges, S. E., & Turner, D. A. (2021) · Clinical Neurology and Neurosurgery · doi:10.1016/j.clineuro.2021.106577 · Cited by 63
Metadata
- Authors
- Shellock, F. G., & Crues, J. V.
- Venue
- Radiology
- Published
- 2004-09
- Volume
- 232
- Issue
- 3
- Pages
- 635-652
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2065765413
- Cited by
- 563
- References
- 51
- FWCI
- 21.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.