The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Coronary Calcium Measurements: Effect of CT Scanner Type and Calcium Measure on Rescan Reproducibility—MESA Study
Abstract
PURPOSE: To evaluate the effect of scanner type and calcium measure on the reproducibility of calcium measurements. MATERIALS AND METHODS: This investigation was approved by the institutional review boards of each study site and by the Institutional Review Board of the Los Angeles Biomedical Research Institute. Informed consent for scanning and participation was obtained from all participants. The study was Health Insurance Portability and Accountability Act compliant. The Multi-Ethnic Study of Atherosclerosis (MESA) is a multicenter observational study of 6814 participants undergoing demographic, risk factor, and subclinical disease evaluations. Coronary artery calcium was measured by using duplicate CT scans. Three study centers used electron-beam computed tomography (CT), and three used multi-detector row CT. Coronary artery calcium was detected in 3355 participants. Three calcium measurement methods-Agatston score, calcium volume, and interpolated volume score-were evaluated. Mean absolute differences between calcium measures on scans 1 and 2, excluding cases for which both scans had a measure of zero, was modeled by using linear regression to compare reproducibility between scanner types. A repeated measures analysis of variance test was used to compare reproducibility across calcium measures, with mean percentage absolute difference as the outcome measure. Rescan reproducibility in relation to misregistrations, noise, and motion artifacts was also examined. Variables were log transformed to create a more normal distribution. RESULTS: Concordance for presence of calcium between duplicate scans was high and similar for both electron-beam and multi-detector row CT (96%, kappa = 0.92). Mean absolute difference between calcium scores for the two scans was 15.8 for electron-beam and 16.9 for multi-detector row CT scanners (P = .06). Mean relative differences were 20.1 for Agatston score, 18.3 for calcium volume, and 18.3 for interpolated volume score (P < .01). Reproducibility was lower for scans with versus those without image misregistrations or motion artifacts (P < .01 for both). CONCLUSION: Electron-beam and multi-detector row CT scanners have equivalent reproducibility for measuring coronary artery calcium. Calcium volumes and interpolated volume scores are slightly more reproducible than Agatston scores. Reproducibility is lower for scans with misregistrations or motion artifacts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Quantification of coronary artery calcium using ultrafast computed tomography
Agatston, A. S., Janowitz, W. R., Hildner, F. J., Zusmer, N. R., Viamonte, M., & Detrano, R. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)90282-t · Cited by 7,786
Self-citationMulti-Ethnic Study of Atherosclerosis: Objectives and Design
Bild, D. E. (2002) · American Journal of Epidemiology · doi:10.1093/aje/kwf113 · Cited by 3,942
Self-citationGreenland, P. (2004) · JAMA · doi:10.1001/jama.291.2.210 · Cited by 1,829
Carr, J. J., Nelson, J. C., Wong, N. D., McNitt-Gray, M., Arad, Y., Jacobs, D. R., Sidney, S., Bild, D. E., Williams, O. D., & Detrano, R. C. (2005) · Radiology · doi:10.1148/radiol.2341040439 · Cited by 853
Self-citationCallister, T. Q., Cooil, B., Raya, S. P., Lippolis, N. J., Russo, D. J., & Raggi, P. (1998) · Radiology · doi:10.1148/radiology.208.3.9722864 · Cited by 750
AAPM/RSNA Physics Tutorial for Residents: Topics in CT: Radiation Dose in CT
McNitt-Gray, M. F. (2002) · RadioGraphics · doi:10.1148/rg.226025128 · Cited by 612
Self-citationCarr, J. J., Crouse, J. R., Goff, D. C., D'Agostino, R. B., Peterson, N. P., & Burke, G. L. (2000) · American Journal of Roentgenology · doi:10.2214/ajr.174.4.1740915 · Cited by 236
Self-citationPark, R., Detrano, R., Xiang, M., Fu, P., Ibrahim, Y., LaBree, L., & Azen, S. (2002) · Circulation · doi:10.1161/01.cir.0000033819.29662.09 · Cited by 224
Self-citationOhnesorge, B., Flohr, T., Fischbach, R., Kopp, A., Knez, A., Schröder, S., Schöpf, U., Crispin, A., Klotz, E., Reiser, M., et al. (2002) · European Radiology · doi:10.1007/s00330-002-1394-2 · Cited by 185
Wang, S., Detrano, R., Secci, A., Tang, W., Doherty, T. M., Puentes, G., Wong, N. D., & Brundage, B. H. (1996) · American Heart Journal · doi:10.1016/s0002-8703(96)90237-9 · Cited by 142
Self-citationReproducibility of the measurement of coronary calcium with ultrafast computed tomography
Devries, S. R., Wolfkiel, C. J., Shah, V. T., Chomka, E. V., & Rich, S. (1995) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)80706-1 · Cited by 133
Detection and quantification of coronary artery calcification with electron-beam and conventional CT
Becker, C. R., Knez, A., Jakobs, T., Aydemir, S., Becker, A., Schoepf, U. J., Bruening, R., Haberl, R., & Reiser, M. F. (1999) · European Radiology · doi:10.1007/s003300050720 · Cited by 113
Effect of Electrocardiogram Triggering on Reproducibility of Coronary Artery Calcium Scoring
Mao, S., Bakhsheshi, H., Lü, B., Liu, S. C. K., Oudiz, R. J., & Budoff, M. J. (2001) · Radiology · doi:10.1148/radiol.2203001129 · Cited by 95
Measuring Coronary Calcium on CT Images Adjusted for Attenuation Differences
Nelson, J. C., Kronmal, R. A., Carr, J. J., McNitt‐Gray, M. F., Wong, N. D., Loria, C. M., Goldin, J. G., Williams, O. D., & Detrano, R. (2005) · Radiology · doi:10.1148/radiol.2352040515 · Cited by 90
Self-citationKajinami, K., Seki, H., Takekoshi, N., & Mabuchi, H. (1993) · Coronary Artery Disease · doi:10.1097/00019501-199312000-00011 · Cited by 64
Reliability of electron beam computed tomography to detect coronary artery calcification.
Jp, S., Ch, M., Rockwood, T. H., Short, R. A., & Viren, F. K. (1995) · PubMed · Cited by 58
Offline assessment of atherosclerotic coronary calcium from electron beam tomograms.
Yaghoubi, S. S., Tang, W., Wang, S., Reed, J. E., Hsiai, J., Detrano, R., & Brundage, B. H. (1995) · PubMed · Cited by 44
Self-citationMöhlenkamp, S., Behrenbeck, T. R., Pump, H., Kriener, P., Lange, S., Baumgart, D., Seibel, R. M. M., Grönemeyer, D. H. W., & Erbel, R. (2001) · International journal of cardiac imaging · doi:10.1023/a:1010619216797 · Cited by 16
Cited by
Budoff, M. J., Achenbach, S., Blumenthal, R. S., Carr, J. J., Goldin, J. G., Greenland, P., Guerci, A. D., Lima, J. A. C., Rader, D. J., Rubin, G. D., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.178458 · Cited by 1,398
Self-citationMcClelland, R. L., Chung, H., Detrano, R., Post, W., & Kronmal, R. A. (2006) · Circulation · doi:10.1161/circulationaha.105.580696 · Cited by 885
Self-citationEstrogen Therapy and Coronary-Artery Calcification
Manson, J. E., Allison, M. A., Rossouw, J. E., Carr, J. J., Langer, R. D., Hsia, J., Kuller, L. H., Cochrane, B. B., Hunt, J. R., Ludlam, S. E., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa071513 · Cited by 711
Self-citationMcClelland, R. L., Jorgensen, N. W., Budoff, M., Blaha, M. J., Post, W. S., Kronmal, R. A., Bild, D. E., Shea, S., Liu, K., Watson, K. E., et al. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.08.035 · Cited by 681
Self-citationCalcium Density of Coronary Artery Plaque and Risk of Incident Cardiovascular Events
Criqui, M. H., Denenberg, J. O., Ix, J. H., McClelland, R. L., Wassel, C. L., Rifkin, D. E., Carr, J. J., Budoff, M. J., & Allison, M. A. (2014) · JAMA · doi:10.1001/jama.2013.282535 · Cited by 642
Self-citation
Metadata
- Authors
- Detrano, R. C., Anderson, M., Nelson, J., Wong, N. D., Carr, J. J., McNitt-Gray, M., & Bild, D. E.
- Venue
- Radiology
- Published
- 2005-08
- Volume
- 236
- Issue
- 2
- Pages
- 477-484
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2130289472
- Cited by
- 298
- References
- 20
- FWCI
- 15.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.