Use of an Automatic Exposure Control Mechanism for Dose Optimization in Multi–Detector Row CT Examinations: Clinical Evaluation
Abstract
PURPOSE: To prospectively compare dose reduction and image quality achieved with an automatic exposure control system that is based on both angular (x-y axis) and z-axis tube current modulation with dose reduction and image quality achieved with an angular modulation system for multi-detector row computed tomography (CT). MATERIALS AND METHODS: The study protocol was approved by the institutional review board, and oral informed consent was obtained. In two groups of 200 patients, five anatomic regions (ie, the thorax, abdomen-pelvis, abdomen-liver, lumbar spine, and cervical spine) were examined with this modulation system and a six-section multi-detector row CT scanner. Data from these patients were compared with data from 200 patients who were examined with an angular modulation system. Dose reduction by means of reduction of the mean effective tube current in 600 examinations, image noise in 200 examinations performed with each modulation system, and subjective image quality scores in 100 examinations per-formed with each modulation system were compared with Wilcoxon signed rank tests. RESULTS: Mean dose reduction for the angular and z-axis tube current modulation system and for the angular modulation system was as follows: thorax, 20% and 14%, respectively; abdomen-liver, 38% and 18%, respectively; abdomen-pelvis, 32% and 26%, respectively; lumbar spine, 37% and 10%, respectively; and cervical spine, 68% and 16%, respectively. These differences were statistically significant (P < .05). There was no significant difference in image noise and mean image quality scores between modulation systems, with the exception of cervical spinal examinations (P < .001 for both), where the examinations with angular modulation resulted in better scores. There is good correlation between the mean effective tube current level and the body mass index of patients with the new modulation system. Correlation was as follows: thorax, 0.77; abdomen-pelvis, 0.83; abdomen-liver, 0.84; lumbar spine, 0.8; and cervical spine, 0.6. This correlation was not observed with the angular modulation system. CONCLUSION: An automatic exposure control mechanism that is based on real-time anatomy-dependent tube current modulation delivers good image quality with a significantly reduced radiation dose.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760289 · Cited by 3,222
Risk of cancer from diagnostic X-rays: estimates for the UK and 14 other countries
de González, A. B., & Darby, S. (2004) · The Lancet · doi:10.1016/s0140-6736(04)15433-0 · Cited by 1,718
Strategies for CT Radiation Dose Optimization
Kalra, M. K., Maher, M. M., Toth, T. L., Hamberg, L. M., Blake, M. A., Shepard, J.-A., & Saini, S. (2004) · Radiology · doi:10.1148/radiol.2303021726 · Cited by 1,080
Peripheral lung cancer: screening and detection with low-dose spiral CT versus radiography.
Kaneko, M., Eguchi, K., Ohmatsu, H., Kakinuma, R., Naruke, T., Suemasu, K., & Moriyama, N. (1996) · Radiology · doi:10.1148/radiology.201.3.8939234 · Cited by 831
Estimated Radiation Risks Potentially Associated with Full-Body CT Screening
Brenner, D. J., & Elliston, C. D. (2004) · Radiology · doi:10.1148/radiol.2323031095 · Cited by 685
OBESITY, N. I. O. H. C. D. P. O. T. H. I. O. (1985) · Annals of Internal Medicine · doi:10.7326/0003-4819-103-6-1073 · Cited by 470
National Conference on Dose Reduction in CT, with an Emphasis on Pediatric Patients
Linton, O. W., & Mettler, F. A. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.181.2.1810321 · Cited by 380
Managing patient dose in computed tomography
(2000) · Annals of the ICRP · doi:10.1016/s0146-6453(01)00049-5 · Cited by 375
Sigal-Cinqualbre, A. B., Hennequin, R., Abada, H. T., Chen, X., & Paul, J.-F. (2004) · Radiology · doi:10.1148/radiol.2311030191 · Cited by 372
Dose reduction in CT by anatomically adapted tube current modulation. I. Simulation studies
Gies, M., Kalender, W. A., Wolf, H., Suess, C., & Madsen, M. T. (1999) · Medical Physics · doi:10.1118/1.598779 · Cited by 306
Dose Reduction in Pediatric CT: A Rational Approach
Boone, J. M., Geraghty, E. M., Seibert, J. A., & Wootton-Gorges, S. L. (2003) · Radiology · doi:10.1148/radiol.2282020471 · Cited by 253
Kalender, W. A., Wolf, H., Suess, C., Gies, M., Greess, H., & Bautz, W. A. (1999) · European Radiology · doi:10.1007/s003300050674 · Cited by 245
Greess, H., Wolf, H., Baum, U., Lell, M., Pirkl, M., Kalender, W., & Bautz, W. A. (2000) · European Radiology · doi:10.1007/s003300050062 · Cited by 230
Greess, H., Nömayr, A., Wolf, H., Baum, U., Lell, M., Böwing, B., Kalender, W., & Bautz, W. A. (2002) · European Radiology · doi:10.1007/s00330-001-1255-4 · Cited by 192
The ALARA Concept in Pediatric CT: Myth or Reality?
Slovis, T. L. (2002) · Radiology · doi:10.1148/radiol.2231012100 · Cited by 180
Dose and Pitch Relationship for a Particular Multislice CT Scanner
Mahesh, M., Scatarige, J. C., Cooper, J., & Fishman, E. K. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.6.1771273 · Cited by 138
CODY, D. D., Moxley, D. M., Krugh, K. T., O'Daniel, J. C., Wagner, L. K., & Eftekhari, F. (2004) · American Journal of Roentgenology · doi:10.2214/ajr.182.4.1820849 · Cited by 117
Common Terminology for Single and Multislice Helical CT
Silverman, P. M., Kalender, W. A., & Hazle, J. D. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.5.1761135 · Cited by 96
Lung Cancer Screening: Minimum Tube Current Required for Helical CT
Itoh, S., Ikeda, M., Arahata, S., Kodaira, T., Isomura, T., Kato, T., Yamakawa, K., Maruyama, K., & Ishigaki, T. (2000) · Radiology · doi:10.1148/radiology.215.1.r00ap16175 · Cited by 78
Slovis, T. L. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.179.1.1790039 · Cited by 71
Cited by
Strategies for Reducing Radiation Dose in CT
McCollough, C. H., Primak, A. N., Braun, N., Kofler, J., Yu, L., & Christner, J. (2009) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2008.10.006 · Cited by 842
The Measurement, Reporting, and Management of Radiation Dose in CT
McCollough, C., Cody, D., Edyvean, S., Geise, R., Gould, B., Keat, N., Huda, W., Judy, P., Kalender, W., McNitt-Gray, M., et al. (2008) · doi:10.37206/97 · Cited by 569
Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating
Husmann, L., Valenta, I., Gaemperli, O., Adda, O., Treyer, V., Wyss, C. A., Veit-Haibach, P., Tatsugami, F., von Schulthess, G. K., & Kaufmann, P. A. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm613 · Cited by 530
SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT
Halliburton, S. S., Abbara, S., Chen, M. Y., Gentry, R., Mahesh, M., Raff, G. L., Shaw, L. J., & Hausleiter, J. (2011) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2011.06.001 · Cited by 491
Increasing utilization of computed tomography in the adult emergency department, 2000–2005
Broder, J., & Warshauer, D. M. (2006) · Emergency Radiology · doi:10.1007/s10140-006-0493-9 · Cited by 478
Metadata
- Authors
- Mulkens, T. H., Bellinck, P., Baeyaert, M., Ghysen, D., Van Dijck, X., Mussen, E., Venstermans, C., & Termote, J.-L.
- Venue
- Radiology
- Published
- 2005-10
- Volume
- 237
- Issue
- 1
- Pages
- 213-223
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2142102898
- Cited by
- 354
- References
- 20
- FWCI
- 17.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.