Integrated PET/CT: Current Applications and Future Directions
The DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Abstract
For the past 5 years, combined positron emission tomography (PET) and computed tomography (CT), or PET/CT, has grown because the PET portion provides information that is very different from that obtainable with other imaging modalities. However, the paucity of anatomic landmarks on PET images makes a consistent "hardware fusion" to anatomic cross-sectional data extremely useful. Clinical experience indicates a single direction: Addition of CT to PET improves specificity foremost, but also sensitivity, and the addition of PET to CT adds sensitivity and specificity in tumor imaging. Thus, PET/CT is a more accurate test than either of its individual components and is probably also better than side-by-side viewing of images from both modalities. The synergistic advantage of adding CT is that the attenuation correction needed for PET can also be derived from the CT data, an advantage not obtainable by integrating PET and magnetic resonance imaging. This makes PET/CT 25%-30% faster than PET alone with standard attenuation-correction methods, leading to higher patient throughput and a more comfortable examination, which typically last 30 minutes or less. Fluorodeoxyglucose (FDG) PET/CT appears to provide relevant information in the staging and therapy monitoring of many tumors, including lung carcinoma, mesothelioma, colorectal cancer, lymphoma, melanoma, and many others, with the notable exception of prostatic cancer. For prostatic cancer, choline derivatives may become useful radiopharmaceuticals. The published literature on the applications of FDG PET/CT in oncology is still limited, but several well-designed studies have demonstrated the benefits of PET/CT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Joensuu, H., Roberts, P. J., Sarlomo-Rikala, M., Andersson, L. C., Tervahartiala, P., Tuveson, D., Silberman, S. L., Capdeville, R., Dimitrijevic, S., Druker, B., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejm200104053441404 · Cited by 2,037
A combined PET/CT scanner for clinical oncology.
Beyer, T., Townsend, D. W., Brun, T., Kinahan, P. E., Charron, M., Roddy, R., Jerin, J., Young, J., Byars, L. G., & Nutt, R. (2000) · PubMed · Cited by 1,659
Lardinois, D., Weder, W., Hany, T. F., Kamel, E. M., Korom, S., Seifert, B., von Schulthess, G. K., & Steinert, H. C. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022136 · Cited by 1,416
Self-citationAttenuation correction for a combined 3D PET/CT scanner
Kinahan, P. E., Townsend, D. W., Beyer, T., & Sashin, D. (1998) · Medical Physics · doi:10.1118/1.598392 · Cited by 946
(2001) · PubMed · Cited by 943
Impact of FDG-PET on radiation therapy volume delineation in non–small-cell lung cancer
Bradley, J., Thorstad, W. L., Mutic, S., Miller, T. R., Dehdashti, F., Siegel, B. A., Bosch, W., & Bertrand, R. J. (2004) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2003.10.044 · Cited by 556
Ciernik, I. F., Dizendorf, E., Baumert, B. G., Reiner, B., Burger, C., Davis, J. B., Lütolf, U. M., Steinert, H. C., & Von Schulthess, G. K. (2003) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(03)00346-8 · Cited by 543
Self-citationNon–Small Cell Lung Cancer: Dual-Modality PET/CT in Preoperative Staging
Antoch, G., Stattaus, J., Nemat, A. T., Marnitz, S., Beyer, T., Kuehl, H., Bockisch, A., Debatin, J. F., & Freudenberg, L. S. (2003) · Radiology · doi:10.1148/radiol.2292021598 · Cited by 540
Resection of Hepatic Metastases from Colorectal Cancer Biologic Perspectives
STEELE, G., & RAVIKUMAR, T. S. (1989) · Annals of Surgery · doi:10.1097/00000658-198908000-00001 · Cited by 525
Lymph Node Staging by Positron Emission Tomography in Patients With Carcinoma of the Cervix
Grigsby, P. W., Siegel, B. A., & Dehdashti, F. (2001) · Journal of Clinical Oncology · doi:10.1200/jco.2001.19.17.3745 · Cited by 471
Research works printed but not linked: 25
- Nehmeh SA, Erdi YE, Kalaigian H, et al. Correction for oral contrast artifacts in CT attenuation-corrected PET images obtained by combined PET/CT.J Nucl Med2003;44:1940–1944.
- 10.1007/s00259-002-1055-3 · doi:10.1007/s00259-002-1055-3
- 10.1007/s00261-003-0163-2 · doi:10.1007/s00261-003-0163-2
- 10.1016/S0003-4975(00)01817-8 · doi:10.1016/s0003-4975(00)01817-8
- 10.1067/msy.2001.116919 · doi:10.1067/msy.2001.116919
- 10.1148/radiol.2323031065 · doi:10.1148/radiol.2323031065
- 10.1007/s00259-004-1633-7 · doi:10.1007/s00259-004-1633-7
- 10.1093/annonc/mdf664 · doi:10.1093/annonc/mdf664
- 10.3816/CLM.2002.n.012 · doi:10.3816/clm.2002.n.012
- 10.2214/ajr.182.6.1821579 · doi:10.2214/ajr.182.6.1821579
- Kitagawa Y, Nishizawa S, Sano K, et al. Prospective comparison of 18F-FDG PET with conventional imaging modalities (MRI, CT, and 67Ga scintigraphy) in assessment of combined intraarterial chemotherapy and radiotherapy for head and neck carcinoma.J Nucl Med2003;44:198–206.
- 10.1148/radiol.2311030271 · doi:10.1148/radiol.2311030271
- Rogers JW, Greven KM, McGuirt WF, et al.Can post-RT neck dissection be omitted for patients with head-and-neck cancer who have a negative PET scan after definitive radiation therapy? Int J Radiat Oncol Biol Phys2004;58:694–697. · doi:10.1016/s0360-3016(03)01625-0
- 10.1148/radiol.2332031800 · doi:10.1148/radiol.2332031800
- Picchio M, Sironi S, Messa C, et al. Advanced ovarian carcinoma: usefulness of [(18)F]FDG-PET in combination with CT for lesion detection after primary treatment.Q J Nucl Med2003;47:77–84.
- 10.1002/1097-0142(19920601)69:11<2796::AID-CNCR2820691127>3.0.CO;2-O · doi:10.1002/1097-0142(19920601)69:11<2796::aid-cncr2820691127>3.0.co;2-o
- 10.1016/j.ygyno.2004.05.053 · doi:10.1016/j.ygyno.2004.05.053
- 10.1007/s00259-004-1536-7 · DOI
- Dizendorf E, Baumert B, von Schulthess GK, Luetolf UM, Steinert HC. The impact of 18F-fluorodeoxyglucose positron emission tomography (FDG-PET) on planning of radiotherapy [in Russian].Ter Arkh2001;73:11–14.
- 10.1046/j.1464-410X.2003.04297.x · doi:10.1046/j.1464-410x.2003.04297.x
- 10.1111/j.1464-410X.2003.04692.x · doi:10.1111/j.1464-410x.2003.04692.x
- 10.1148/radiol.2352040494 · doi:10.1148/radiol.2352040494
- 10.1016/S0969-8051(03)00097-0 · doi:10.1016/s0969-8051(03)00097-0
- de Winter F, van de Wiele C, Vogelaers D, de Smet K, Verdonk R, Dierckx RA. Fluorine-18 fluorodeoxyglucose-position emission tomography: a highly accurate imaging modality for the diagnosis of chronic musculoskeletal infections.J Bone Joint Surg Am2001; 83-A:651–660. · doi:10.2106/00004623-200105000-00002
- 10.1148/radiol.2312021596 · DOI
Cited by
New approaches for imaging tumour responses to treatment
Brindle, K. (2008) · Nature Reviews Cancer · doi:10.1038/nrc2289 · Cited by 460
Imaging diagnosis of pancreatic cancer: A state-of-the-art review
Lee, E. S. (2014) · World Journal of Gastroenterology · doi:10.3748/wjg.v20.i24.7864 · Cited by 401
Hillner, B. E., Siegel, B. A., Liu, D., Shields, A. F., Gareen, I. F., Hanna, L., Stine, S. H., & Coleman, R. E. (2008) · Journal of Clinical Oncology · doi:10.1200/jco.2007.14.5631 · Cited by 374
FDG PET/CT in infection and inflammation—current and emerging clinical applications
Vaidyanathan, S., Patel, C. N., Scarsbrook, A. F., & Chowdhury, F. U. (2015) · Clinical Radiology · doi:10.1016/j.crad.2015.03.010 · Cited by 344
Plathow, C., & Weber, W. A. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.045930 · Cited by 328
Combined FDG-PET/CT for the detection of unknown primary tumors: systematic review and meta-analysis
Kwee, T. C., & Kwee, R. M. (2009) · European Radiology · doi:10.1007/s00330-008-1194-4 · Cited by 317
Quantitative Ultrasound in Soft Tissues
(2013) · Springer eBooks · doi:10.1007/978-94-007-6952-6 · Cited by 302
Doi, K. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/13/r02 · Cited by 290
Multimodality imaging of structure and function
Townsend, D. W. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/4/r01 · Cited by 286
Current status and progress of pancreatic cancer in China
Lin, Q.-J. (2015) · World Journal of Gastroenterology · doi:10.3748/wjg.v21.i26.7988 · Cited by 285
Buck, A. K., Nekolla, S., Ziegler, S., Beer, A., Krause, B. J., Herrmann, K., Scheidhauer, K., Wester, H.-J., Rummeny, E. J., Schwaiger, M., et al. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.050195 · Cited by 282
Imaging in assessing lymph node status in gastric cancer
Kwee, R. M., & Kwee, T. C. (2009) · Gastric Cancer · doi:10.1007/s10120-008-0492-5 · Cited by 282
Texture Analysis of Aggressive and Nonaggressive Lung Tumor CE CT Images
Al-Kadi, O. S., & Watson, D. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.919735 · Cited by 268
Imaging in staging of malignant lymphoma: a systematic review
Kwee, T. C., Kwee, R. M., & Nievelstein, R. A. J. (2008) · Blood · doi:10.1182/blood-2007-07-101899 · Cited by 264
11C-l-Methionine Positron Emission Tomography in the Clinical Management of Cerebral Gliomas
Singhal, T., Narayanan, T. K., Jain, V., Mukherjee, J., & Mantil, J. (2008) · Molecular Imaging and Biology · doi:10.1007/s11307-007-0115-2 · Cited by 227
“availability of PET/CT scanners [132], more studies using Bhardware fusion^ of METYPET and CT for treatment planning are expected in the future to improve the outcome in these patients.”
MethodOverview of the clinical effectiveness of positron emission tomography imaging in selected cancers
Facey, K., Bradbury, I., Laking, G., & Payne, E. (2007) · Health Technology Assessment · doi:10.3310/hta11440 · Cited by 219
Seo, Y., Mari, C., & Hasegawa, B. H. (2008) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2008.01.001 · Cited by 198
Molecular imaging for personalized cancer care
Kircher, M. F., Hricak, H., & Larson, S. M. (2012) · Molecular Oncology · doi:10.1016/j.molonc.2012.02.005 · Cited by 193
Choline metabolism in cancer: implications for diagnosis and therapy
Glunde, K., Jacobs, M. A., & Bhujwalla, Z. M. (2006) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.6.6.821 · Cited by 185
PET Imaging of Soluble Yttrium-86-Labeled Carbon Nanotubes in Mice
McDevitt, M. R., Chattopadhyay, D., Jaggi, J. S., Finn, R. D., Zanzonico, P. B., Villa, C., Rey, D., Mendenhall, J., Batt, C. A., Njardarson, J. T., et al. (2007) · PLoS ONE · doi:10.1371/journal.pone.0000907 · Cited by 184
Imaging and treating tumor vasculature with targeted radiolabeled carbon nanotubes
McDevitt, M., McDevitt, M., Ruggiero, A., Villa, C. H., Holland, J. P., Sprinkle, S. R., May, C., Lewis, J., & Scheinberg, D. (2010) · International Journal of Nanomedicine · doi:10.2147/ijn.s13300 · Cited by 171
Nuclear imaging of neuroendocrine tumours
Sundin, A., Garske, U., & Örlefors, H. (2007) · Best Practice & Research Clinical Endocrinology & Metabolism · doi:10.1016/j.beem.2006.12.003 · Cited by 160
Eskian, M., Alavi, A., Khorasanizadeh, M., Viglianti, B. L., Jacobsson, H., Barwick, T. D., Meysamie, A., Yi, S. K., Iwano, S., Bybel, B., et al. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-018-4194-x · Cited by 109
Tatli, S., Gerbaudo, V. H., Mamede, M., Tuncali, K., Shyn, P. B., & Silverman, S. G. (2010) · Radiology · doi:10.1148/radiol.10090931 · Cited by 103
Time to Progression of Pancreatic Cancer: Evaluation with Multi-Detector Computed Tomography
Ahn, S. J., Choi, S. J., & Kim, H. S. (2017) · Journal of Gastrointestinal Cancer · doi:10.1007/s12029-016-9876-7 · Cited by 32
Nakajo, M., Jinguji, M., Nakajo, M., Shinaji, T., Nakabeppu, Y., Fukukura, Y., & Yoshiura, T. (2017) · Abdominal Radiology · doi:10.1007/s00261-017-1207-3 · Cited by 32
“Glucose analogue F-18-fluorodeoxyglucose (FDG) uptake represents glucose metabolic activity and is widely used as a tracer for positron emission tomography (PET)/CT in oncology [5].”
Background
Metadata
- Authors
- von Schulthess, G. K., Steinert, H. C., & Hany, T. F.
- Venue
- Radiology
- Published
- 2006-02
- Volume
- 238
- Issue
- 2
- Pages
- 405-422
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2020657588
- Cited by
- 619
- References
- 54
- FWCI
- 48.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.