The DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Integrated PET/CT: Current Applications and Future Directions
Abstract
For the past 5 years, combined positron emission tomography (PET) and computed tomography (CT), or PET/CT, has grown because the PET portion provides information that is very different from that obtainable with other imaging modalities. However, the paucity of anatomic landmarks on PET images makes a consistent "hardware fusion" to anatomic cross-sectional data extremely useful. Clinical experience indicates a single direction: Addition of CT to PET improves specificity foremost, but also sensitivity, and the addition of PET to CT adds sensitivity and specificity in tumor imaging. Thus, PET/CT is a more accurate test than either of its individual components and is probably also better than side-by-side viewing of images from both modalities. The synergistic advantage of adding CT is that the attenuation correction needed for PET can also be derived from the CT data, an advantage not obtainable by integrating PET and magnetic resonance imaging. This makes PET/CT 25%-30% faster than PET alone with standard attenuation-correction methods, leading to higher patient throughput and a more comfortable examination, which typically last 30 minutes or less. Fluorodeoxyglucose (FDG) PET/CT appears to provide relevant information in the staging and therapy monitoring of many tumors, including lung carcinoma, mesothelioma, colorectal cancer, lymphoma, melanoma, and many others, with the notable exception of prostatic cancer. For prostatic cancer, choline derivatives may become useful radiopharmaceuticals. The published literature on the applications of FDG PET/CT in oncology is still limited, but several well-designed studies have demonstrated the benefits of PET/CT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Joensuu, H., Roberts, P. J., Sarlomo-Rikala, M., Andersson, L. C., Tervahartiala, P., Tuveson, D., Silberman, S. L., Capdeville, R., Dimitrijevic, S., Druker, B., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejm200104053441404 · Cited by 2,037
A combined PET/CT scanner for clinical oncology.
Beyer, T., Townsend, D. W., Brun, T., Kinahan, P. E., Charron, M., Roddy, R., Jerin, J., Young, J., Byars, L. G., & Nutt, R. (2000) · PubMed · Cited by 1,659
Lardinois, D., Weder, W., Hany, T. F., Kamel, E. M., Korom, S., Seifert, B., von Schulthess, G. K., & Steinert, H. C. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022136 · Cited by 1,416
Self-citationAttenuation correction for a combined 3D PET/CT scanner
Kinahan, P. E., Townsend, D. W., Beyer, T., & Sashin, D. (1998) · Medical Physics · doi:10.1118/1.598392 · Cited by 946
(2001) · PubMed · Cited by 943
Impact of FDG-PET on radiation therapy volume delineation in non–small-cell lung cancer
Bradley, J., Thorstad, W. L., Mutic, S., Miller, T. R., Dehdashti, F., Siegel, B. A., Bosch, W., & Bertrand, R. J. (2004) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2003.10.044 · Cited by 556
Ciernik, I. F., Dizendorf, E., Baumert, B. G., Reiner, B., Burger, C., Davis, J. B., Lütolf, U. M., Steinert, H. C., & Von Schulthess, G. K. (2003) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(03)00346-8 · Cited by 543
Self-citationNon–Small Cell Lung Cancer: Dual-Modality PET/CT in Preoperative Staging
Antoch, G., Stattaus, J., Nemat, A. T., Marnitz, S., Beyer, T., Kuehl, H., Bockisch, A., Debatin, J. F., & Freudenberg, L. S. (2003) · Radiology · doi:10.1148/radiol.2292021598 · Cited by 540
Resection of Hepatic Metastases from Colorectal Cancer Biologic Perspectives
STEELE, G., & RAVIKUMAR, T. S. (1989) · Annals of Surgery · doi:10.1097/00000658-198908000-00001 · Cited by 525
Lymph Node Staging by Positron Emission Tomography in Patients With Carcinoma of the Cervix
Grigsby, P. W., Siegel, B. A., & Dehdashti, F. (2001) · Journal of Clinical Oncology · doi:10.1200/jco.2001.19.17.3745 · Cited by 471
Uptake in supraclavicular area fat ("USA-Fat"): description on 18F-FDG PET/CT.
Cohade, C., Osman, M., Pannu, H. K., & Wahl, R. L. (2003) · PubMed · Cited by 440
Antoch, G., Saoudi, N., Kuehl, H., Dahmen, G., Mueller, S. P., Beyer, T., Bockisch, A., Debatin, J. F., & Freudenberg, L. S. (2004) · Journal of Clinical Oncology · doi:10.1200/jco.2004.08.120 · Cited by 435
Burger, C., Goerres, G., Schoenes, S., Buck, A., Lonn, A., & von Schulthess, G. (2002) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-002-0796-3 · Cited by 428
Self-citationAbdel-Nabi, H., Doerr, R. J., Lamonica, D. M., Cronin, V. R., Galantowicz, P. J., Carbone, G. M., & Spaulding, M. B. (1998) · Radiology · doi:10.1148/radiology.206.3.9494497 · Cited by 424
Schaefer, N. G., Hany, T. F., Taverna, C., Seifert, B., Stumpe, K. D. M., von Schulthess, G. K., & Goerres, G. W. (2004) · Radiology · doi:10.1148/radiol.2323030985 · Cited by 364
Self-citationIn vivo assessment of glucose metabolism in hepatocellular carcinoma with FDG-PET.
Torizuka, T., Tamaki, N., Inokuma, T., Magata, Y., Sasayama, S., Yonekura, Y., Tanaka, A., Yamaoka, Y., Yamamoto, K., & Konishi, J. (1995) · PubMed · Cited by 357
Selzner, M., Hany, T. F., Wildbrett, P., McCormack, L., Kadry, Z., & Clavien, P.-A. (2004) · Annals of Surgery · doi:10.1097/01.sla.0000146145.69835.c5 · Cited by 348
Self-citationPET Diagnostic Accuracy: Improvement with In-Line PET-CT System: Initial Results
Hany, T. F., Steinert, H. C., Goerres, G. W., Buck, A., & von Schulthess, G. K. (2002) · Radiology · doi:10.1148/radiol.2252011568 · Cited by 323
Self-citationHeinrich, S., Goerres, G. W., Schäfer, M., Sagmeister, M., Bauerfeind, P., Pestalozzi, B. C., Hany, T. F., von Schulthess, G. K., & Clavien, P.-A. (2005) · Annals of Surgery · doi:10.1097/01.sla.0000172095.97787.84 · Cited by 321
Self-citationDirect comparison of (18)F-FDG PET and PET/CT in patients with colorectal carcinoma.
Cohade, C., Osman, M., Leal, J. P., & Wahl, R. L. (2003) · PubMed · Cited by 314
Antoch, G., Kanja, J., Bauer, S., Kuehl, H., Renzing-Koehler, K., Schuette, J., Bockisch, A., Debatin, J. F., & Freudenberg, L. S. (2004) · PubMed · Cited by 312
Ovarian cancer: Age contrasts in incidence, histology, disease stage at diagnosis, and mortality
Yancik, R. (2010) · Cancer · doi:10.1002/cncr.2820710205 · Cited by 309
Lymphoma: role of whole-body 2-deoxy-2-[F-18]fluoro-D-glucose (FDG) PET in nodal staging.
Moog, F., Bangerter, M., Diederichs, C. G., Guhlmann, A., Kotzerke, J., Merkle, E., Kolokythas, O., Herrmann, F., & Reske, S. N. (1997) · Radiology · doi:10.1148/radiology.203.3.9169707 · Cited by 309
Ruers, T. J. M., Langenhoff, B. S., Neeleman, N., Jager, G. J., Strijk, S. P., Wobbes, T., Corstens, F. H. M., & Oyen, W. J. G. (2002) · Journal of Clinical Oncology · doi:10.1200/jco.20.2.388 · Cited by 293
Lerman, H., Metser, U., Grisaru, D., Fishman, A., Lievshitz, G., & Even‐Sapir, E. (2004) · PubMed · Cited by 279
Whole-Body18F Dopa PET for Detection of Gastrointestinal Carcinoid Tumors
Hoegerle, S., Altehoefer, C., Ghanem, N., Koehler, G., Waller, C. F., Scheruebl, H., Moser, E., & Nitzsche, E. (2001) · Radiology · doi:10.1148/radiology.220.2.r01au25373 · Cited by 269
Goldberg, R. M., Fleming, T. R., Tangen, C. M., Moertel, C. G., Macdonald, J. S., Haller, D. G., & Laurie, J. A. (1998) · Annals of Internal Medicine · doi:10.7326/0003-4819-129-1-199807010-00007 · Cited by 265
Stumpe, K. D. M., Urbinelli, M., Steinert, H. C., Glanzmann, C., Buck, A., & von Schulthess, G. K. (1998) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590050275 · Cited by 261
Self-citationBangerter, M., Moog, F., Buchmann, I., Kotzerke, J., Griesshammer, M., Hafner, M., Elsner, K., Frickhofen, N., Reske, S. N., & Bergmann, L. (1998) · Annals of Oncology · doi:10.1023/a:1008486928190 · Cited by 244
Flamen, P., Stroobants, S., Van Cutsem, E., Dupont, P., Bormans, G., De Vadder, N., Penninckx, F., Van Hoe, L., & Mortelmans, L. (1999) · Journal of Clinical Oncology · doi:10.1200/jco.1999.17.3.894 · Cited by 242
Bleeker‐Rovers, C. P., de Kleijn, E. M. H. A., Corstens, F. H. M., van der Meer, J. W. M., & Oyen, W. J. G. (2003) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-003-1338-3 · Cited by 236
Kantorová, I., Lipská, L., Bělohlávek, O., Visokai, V., Trubaĉ, M., & Schneiderová, M. (2003) · PubMed · Cited by 231
Keidar, Z., Haim, N., Guralnik, L., Wollner, M., Bar‐Shalom, R., Ben‐Nun, A., & Israel, O. (2004) · PubMed · Cited by 219
Kostakoglu, L., Leonard, J. P., Kuji, I., Coleman, M., Vallabhajosula, S., & Goldsmith, S. J. (2002) · Cancer · doi:10.1002/cncr.10336 · Cited by 212
Cost-effectiveness of PET imaging in clinical oncology
Valk, P. E., Pounds, T. R., Tesar, R. D., Hopkins, D. M., & Haseman, M. K. (1996) · Nuclear Medicine and Biology · doi:10.1016/0969-8051(96)00080-7 · Cited by 200
Respiration-induced Attenuation Artifact at PET/CT: Technical Considerations
Goerres, G. W., Burger, C., Kamel, E., Seifert, B., Kaim, A. H., Buck, A., Buehler, T. C., & von Schulthess, G. K. (2003) · Radiology · doi:10.1148/radiol.2263011732 · Cited by 198
Self-citationKamel, E. M., Thumshirn, M., Truninger, K., Schiesser, M., Fried, M., Padberg, B. C., Schneiter, D., Stoeckli, S. J., von Schulthess, G. K., & Stumpe, K. D. M. (2004) · PubMed · Cited by 196
Integrated PET/CT for the assessment of coronary artery disease: a feasibility study.
Namdar, M., Hany, T. F., Koepfli, P., Siegrist, P. T., Burger, C., Wyss, C. A., Lüscher, T. F., von Schulthess, G. K., & Kaufmann, P. A. (2005) · PubMed · Cited by 194
Self-citationHeller, P. B., Malfetano, J. H., Bundy, B. N., Barnhill, D. R., & Okagaki, T. (1990) · Gynecologic Oncology · doi:10.1016/0090-8258(90)90085-y · Cited by 194
Kubota, K., Yokoyama, J., Yamaguchi, K., Ono, S., Qureshy, A., Itoh, M., & Fukuda, H. (2004) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-003-1408-6 · Cited by 174
Impact of metallic dental implants on CT-based attenuation correction in a combined PET/CT scanner
Kamel, E. M., Burger, C., Buck, A., von Schulthess, G. K., & Goerres, G. W. (2003) · European Radiology · doi:10.1007/s00330-002-1564-2 · Cited by 163
Self-citationKamel, E. M., Hany, T. F., Burger, C., Treyer, V., Lonn, A. H. R., von Schulthess, G. K., & Buck, A. (2001) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-001-0698-9 · Cited by 152
Self-citationDizendorf, E., Hany, T. F., Buck, A., von Schulthess, G. K., & Burger, C. (2003) · PubMed · Cited by 144
Self-citationVisvikis, D., Costa, D. C., Croasdale, I. R., Lonn, A. H. R., Bomanji, J. B., Gacinovic, S., & Ell, P. J. (2002) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-002-1070-4 · Cited by 138
Value of fluorine-18-FDG-PET to monitor hepatocellular carcinoma after interventional therapy.
Torizuka, T., Tamaki, N., Inokuma, T., Magata, Y., Yonekura, Y., Tanaka, A., Yamaoka, Y., Yamamoto, K., & Konishi, J. (1994) · PubMed · Cited by 128
Schiesser, M., Stumpe, K. D. M., Trentz, O., Kossmann, T., & von Schulthess, G. K. (2003) · Radiology · doi:10.1148/radiol.2262011939 · Cited by 101
Kamel, E. M., Goerres, G. W., Burger, C., von Schulthess, G. K., & Steinert, H. C. (2002) · Radiology · doi:10.1148/radiol.2241011254 · Cited by 99
Self-citationDecision Analysis for the Cost-Effective Management of Recurrent Colorectal Cancer
Park, K. C., Schwimmer, J., Shepherd, J. E., Phelps, M. E., Czernin, J. R., Schiepers, C. W., & Gambhir, S. S. (2001) · Annals of Surgery · doi:10.1097/00000658-200103000-00003 · Cited by 83
PET-CT detection of abdominal recurrence of ovarian cancer: radiologic?surgical correlation
Pannu, H. K., Cohade, C., Bristow, R. E., Fishman, E. K., & Wahl, R. L. (2004) · Abdominal Imaging · doi:10.1007/s00261-003-0118-7 · Cited by 78
Reinartz, P., Wieres, F.-J., Schneider, W., Schur, A., & Buell, U. (2004) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-004-1593-y · Cited by 68
Teflon-induced granuloma: a false-positive finding with PET resolved with combined PET and CT.
Yeretsian, R. A., Blodgett, T. M., Branstetter, B. F., Roberts, M. M., & MELTZER, C. C. (2003) · PubMed · Cited by 56
PET/CT Using 2-Deoxy-2-[18F]Fluoro-D-Glucose for the Evaluation of Suspected Infected Vascular Graft
Keidar, Z. (2003) · Molecular Imaging and Biology · doi:10.1016/s1536-1632(03)00035-0 · Cited by 40
Zijlstra, J. M., Hoekstra, O. S., Raijmakers, P. G. H. M., Comans, E. F. I., van der Hoeven, J. J. M., Teule, G. J. J., Jonkhoff, A. R., van Tinteren, H., Lammertsma, A. A., & Huijgens, P. C. (2003) · British Journal of Haematology · doi:10.1046/j.1365-2141.2003.04617.x · Cited by 40
Investigation of thyroid, head, and neck cancers with PET
Zhuang, H., Kumar, R., Mandel, S. J., & Alavi, A. A. (2004) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2004.07.006 · Cited by 28
Research works printed but not linked: 25
- Nehmeh SA, Erdi YE, Kalaigian H, et al. Correction for oral contrast artifacts in CT attenuation-corrected PET images obtained by combined PET/CT.J Nucl Med2003;44:1940–1944.
- 10.1007/s00259-002-1055-3 · doi:10.1007/s00259-002-1055-3
- 10.1007/s00261-003-0163-2 · doi:10.1007/s00261-003-0163-2
- 10.1016/S0003-4975(00)01817-8 · doi:10.1016/s0003-4975(00)01817-8
- 10.1067/msy.2001.116919 · doi:10.1067/msy.2001.116919
- 10.1148/radiol.2323031065 · doi:10.1148/radiol.2323031065
- 10.1007/s00259-004-1633-7 · doi:10.1007/s00259-004-1633-7
- 10.1093/annonc/mdf664 · doi:10.1093/annonc/mdf664
- 10.3816/CLM.2002.n.012 · doi:10.3816/clm.2002.n.012
- 10.2214/ajr.182.6.1821579 · doi:10.2214/ajr.182.6.1821579
- Kitagawa Y, Nishizawa S, Sano K, et al. Prospective comparison of 18F-FDG PET with conventional imaging modalities (MRI, CT, and 67Ga scintigraphy) in assessment of combined intraarterial chemotherapy and radiotherapy for head and neck carcinoma.J Nucl Med2003;44:198–206.
- 10.1148/radiol.2311030271 · doi:10.1148/radiol.2311030271
- Rogers JW, Greven KM, McGuirt WF, et al.Can post-RT neck dissection be omitted for patients with head-and-neck cancer who have a negative PET scan after definitive radiation therapy? Int J Radiat Oncol Biol Phys2004;58:694–697. · doi:10.1016/s0360-3016(03)01625-0
- 10.1148/radiol.2332031800 · doi:10.1148/radiol.2332031800
- Picchio M, Sironi S, Messa C, et al. Advanced ovarian carcinoma: usefulness of [(18)F]FDG-PET in combination with CT for lesion detection after primary treatment.Q J Nucl Med2003;47:77–84.
- 10.1002/1097-0142(19920601)69:11<2796::AID-CNCR2820691127>3.0.CO;2-O · doi:10.1002/1097-0142(19920601)69:11<2796::aid-cncr2820691127>3.0.co;2-o
- 10.1016/j.ygyno.2004.05.053 · doi:10.1016/j.ygyno.2004.05.053
- 10.1007/s00259-004-1536-7 · DOI
- Dizendorf E, Baumert B, von Schulthess GK, Luetolf UM, Steinert HC. The impact of 18F-fluorodeoxyglucose positron emission tomography (FDG-PET) on planning of radiotherapy [in Russian].Ter Arkh2001;73:11–14.
- 10.1046/j.1464-410X.2003.04297.x · doi:10.1046/j.1464-410x.2003.04297.x
- 10.1111/j.1464-410X.2003.04692.x · doi:10.1111/j.1464-410x.2003.04692.x
- 10.1148/radiol.2352040494 · doi:10.1148/radiol.2352040494
- 10.1016/S0969-8051(03)00097-0 · doi:10.1016/s0969-8051(03)00097-0
- de Winter F, van de Wiele C, Vogelaers D, de Smet K, Verdonk R, Dierckx RA. Fluorine-18 fluorodeoxyglucose-position emission tomography: a highly accurate imaging modality for the diagnosis of chronic musculoskeletal infections.J Bone Joint Surg Am2001; 83-A:651–660. · doi:10.2106/00004623-200105000-00002
- 10.1148/radiol.2312021596 · doi:10.1148/radiol.2312021596
Cited by
New approaches for imaging tumour responses to treatment
Brindle, K. (2008) · Nature Reviews Cancer · doi:10.1038/nrc2289 · Cited by 460
Imaging diagnosis of pancreatic cancer: A state-of-the-art review
Lee, E. S. (2014) · World Journal of Gastroenterology · doi:10.3748/wjg.v20.i24.7864 · Cited by 401
Hillner, B. E., Siegel, B. A., Liu, D., Shields, A. F., Gareen, I. F., Hanna, L., Stine, S. H., & Coleman, R. E. (2008) · Journal of Clinical Oncology · doi:10.1200/jco.2007.14.5631 · Cited by 374
FDG PET/CT in infection and inflammation—current and emerging clinical applications
Vaidyanathan, S., Patel, C. N., Scarsbrook, A. F., & Chowdhury, F. U. (2015) · Clinical Radiology · doi:10.1016/j.crad.2015.03.010 · Cited by 344
Plathow, C., & Weber, W. A. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.045930 · Cited by 328
Metadata
- Authors
- von Schulthess, G. K., Steinert, H. C., & Hany, T. F.
- Venue
- Radiology
- Published
- 2006-02
- Volume
- 238
- Issue
- 2
- Pages
- 405-422
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2020657588
- Cited by
- 619
- References
- 54
- FWCI
- 48.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.