Uterine Leiomyomas: MR Imaging–guided Focused Ultrasound Surgery—Results of Different Treatment Protocols1
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
PURPOSE: To prospectively assess patient response (after 12 months) to magnetic resonance (MR) imaging-guided focused ultrasound surgery in treatment of uterine leiomyomas by using two treatment protocols. MATERIALS AND METHODS: This prospective clinical trial was approved by institutional review boards and was HIPAA compliant. After giving informed consent, patients with symptomatic leiomyomas were consecutively enrolled and treated at one of five U.S. centers by using an original or a modified protocol. Outcomes were assessed with the symptom severity score (SSS) obtained at baseline and 3, 6, and 12 months after treatment. Adverse events (AEs) were recorded. Statistical analysis included Student t test, Fisher exact test, analysis of covariance, Spearman correlation, and logistic regression. RESULTS: One hundred sixty patients had a mean SSS of 62.1 +/- 16.3 (standard deviation) at baseline, which decreased to 35.5 +/- 19.5 at 3 months (P<.001) and to 32.3 +/- 19.8 at 6 months (P<.001) and was 32.7 +/- 21.0 at 12 months (P<.001). Ninety-six patients (mean age, 46.0 years +/- 4.6) were treated with an original protocol, and 64 (mean age, 45.9 years +/- 3.9) were treated with a modified protocol. Patients in the modified group had a significantly greater SSS decrease at 3 months (P=.037) than those in the original group, and 73% of those in the original group and 91% of those in the modified group reported a significant decrease in SSS (of 10 points or greater) at 12 months. No serious AEs were recorded. Fewer AEs were reported in the modified group than in the original group (25% vs 13% reporting no event). Of evaluable patients, fewer in the modified group chose alternative treatment (28%) than in the original group (37%). CONCLUSION: MR imaging-guided focused ultrasound surgery results in symptomatic improvement, sustained to 12 months after treatment. Treatment with a modified protocol results in greater clinical effectiveness and fewer AEs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A precise and fast temperature mapping using water proton chemical shift
Ishihara, Y., Calderon, A., Watanabe, H., Okamoto, K., Suzuki, Y., Kuroda, K., & Suzuki, Y. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340606 · Cited by 1,027 · cited 2×
“MR imaging can quantify temperature changes by exploiting the temperature dependence of the water proton resonant frequency (2), which allows targeting of the beam during subthreshold ultrasound exposures (3) and online estimation of the ablated volume (4,5).”
BackgroundMethodA NEW METHOD FOR THE GENERATION AND USE OF FOCUSED ULTRASOUND IN EXPERIMENTAL BIOLOGY
Lynn, J. G., Zwemer, R. L., Chick, A. J., & Miller, A. E. (1942) · Journal of General Physiology · doi:10.1085/jgp.26.2.179 · Cited by 690 · cited 1×
“The potential surgical application of focused ultrasound surgery was demonstrated more than 6 decades ago (1).”
BackgroundSpies, J. (2002) · Obstetrics & Gynecology · doi:10.1016/s0029-7844(01)01702-1 · Cited by 647 · cited 2×
“SSSs were obtained and transformed to create a summed comparable score (15).”
MethodClinical outcomes of focused ultrasound surgery for the treatment of uterine fibroids
Stewart, E. A., Rabinovici, J., Tempany, C. M. C., Inbar, Y., Regan, L., Gastout, B., Hesley, G., Kim, H. S., Hengst, S., & Gedroye, W. M. (2006) · Fertility and Sterility · doi:10.1016/j.fertnstert.2005.04.072 · Cited by 480 · cited 4×
“This result demonstrates a sustained response in a far greater number of patients in comparison to that in the pivotal study (13), in which only 51% of patients were reported to have a significant clinical response at 12 months.”
BackgroundMethodResultInfluentialSelf-citationMRI Guidance of Focused Ultrasound Therapy of Uterine Fibroids: Early Results
Hindley, J. T., Gedroyc, W. M. W., Regan, L., Stewart, E. A., Tempany, C. M., Hynnen, K., MacDannold, N., Inbar, Y., Itzchak, Y., Rabinovici, J., et al. (2004) · American Journal of Roentgenology · doi:10.2214/ajr.183.6.01831713 · Cited by 441
Self-citationA clinical, noninvasive, MR imaging-monitored ultrasound surgery method
Hynynen, K., Freund, W., Cline, H., Chung, A., Watkins, R., Vetro, J., & Jolesz, F. (1996) · RadioGraphics · doi:10.1148/radiographics.16.1.185 · Cited by 327 · cited 1×
“This system is based on an earlier clinical design (7,16).”
MethodSelf-citationEx vivo tissue‐type independence in proton‐resonance frequency shift MR thermometry
Peters, R. T. D., Hinks, R. S., & Henkelman, R. M. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400316 · Cited by 320
Focused US system for MR imaging-guided tumor ablation.
Cline, H. E., Hynynen, K., Watkins, R. D., Adams, W. J., Schenck, J. F., Ettinger, R. H., Freund, W. R., Vetro, J. P., & Jolesz, F. A. (1995) · Radiology · doi:10.1148/radiology.194.3.7862971 · Cited by 276
Self-citationThe FIBROID Registry: Symptom and Quality-of-Life Status 1 Year After Therapy
Spies, J. B., Myers, E. R., Worthington-Kirsch, R. L., Mulgund, J., Goodwin, S. C., & Mauro, M. A. (2005) · Obstetrics and Gynecology · doi:10.1097/01.aog.0000188386.53878.49 · Cited by 241 · cited 2×
“23) (19) than that after MR imaging– guided focused ultrasound surgery.”
BackgroundMcDannold, N., Tempany, C. M., Fennessy, F. M., So, M. J., Rybicki, F. J., Stewart, E. A., Jolesz, F. A., & Hynynen, K. (2006) · Radiology · doi:10.1148/radiol.2401050717 · Cited by 231 · cited 5×
“Once planning was complete, lowenergy sonications were delivered to confirm correct anatomic location (5,10).”
BackgroundMethodInfluentialSelf-citationThermal effects of focused ultrasound on the brain: determination with MR imaging.
Hynynen, K., Vykhodtseva, N. I., Chung, A. H., Sorrentino, V, Colucci, V, & Jolesz, F. A. (1997) · Radiology · doi:10.1148/radiology.204.1.9205255 · Cited by 229 · cited 1×
“MR imaging can quantify temperature changes by exploiting the temperature dependence of the water proton resonant frequency (2), which allows targeting of the beam during subthreshold ultrasound exposures (3) and online estimation of the ablated volume (4,5).”
BackgroundSelf-citationChung, A. H., Hynynen, K., Colucci, V., Oshio, K., Cline, H. E., & Jolesz, F. A. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360513 · Cited by 198 · cited 2×
“Phase imaging is used to estimate the temperature-dependent proton resonant frequency shift with a fast spoiled gradient-recalled-echo sequence (6).”
MethodSelf-citationKuroda, K., Chung, A. H., Hynynen, K., & Jolesz, F. A. (1998) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880080130 · Cited by 91
Self-citation
Cited by
Schroeder, A., Kost, J., & Barenholz, Y. (2009) · Chemistry and Physics of Lipids · doi:10.1016/j.chemphyslip.2009.08.003 · Cited by 485
High‐intensity focused ultrasound for noninvasive functional neurosurgery
Martin, E., Jeanmonod, D., Morel, A., Zadicario, E., & Werner, B. (2009) · Annals of Neurology · doi:10.1002/ana.21801 · Cited by 468
MRI-Guided Focused Ultrasound Surgery
Jolesz, F. A. (2009) · Annual Review of Medicine · doi:10.1146/annurev.med.60.041707.170303 · Cited by 377
Self-citationSustained Relief of Leiomyoma Symptoms by Using Focused Ultrasound Surgery
Stewart, E. A., Gostout, B., Rabinovici, J., Kim, H. S., Regan, L., & Tempany, C. M. C. (2007) · Obstetrics & Gynecology · doi:10.1097/01.aog.0000275283.39475.f6 · Cited by 332
Self-citationKöhler, M. O., Mougenot, C., Quesson, B., Enholm, J., Le Bail, B., Laurent, C., Moonen, C. T. W., & Ehnholm, G. J. (2009) · Medical Physics · doi:10.1118/1.3152112 · Cited by 307
Metadata
- Authors
- Fennessy, F. M., Tempany, C. M., McDannold, N. J., So, M. J., Hesley, G., Gostout, B., Kim, H. S., Holland, G. A., Sarti, D. A., Hynynen, K., Jolesz, F. A., & Stewart, E. A.
- Venue
- Radiology
- Published
- 2007-06
- Volume
- 243
- Issue
- 3
- Pages
- 885-893
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W1984333380
- Cited by
- 242
- References
- 13
- FWCI
- 23.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.