Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 603

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Complications of Diagnostic Cerebral Angiography: Evaluation of 19 826 Consecutive Patients1

Kaufmann, Timothy J., Huston, John, Mandrekar, Jay N., Schleck, Cathy D., Thielen, Kent R., Kallmes, David F.·2007·Radiology

Abstract

PURPOSE: To retrospectively evaluate the complications of diagnostic cerebral catheter angiography in 19,826 consecutive patients. MATERIALS AND METHODS: This HIPAA-compliant study had institutional review board approval, with waiver of informed consent. Demographic, procedural, and complication data in 19 826 consecutive patients undergoing diagnostic cerebral angiography at one institution from 1981 through 2003 were retrospectively reviewed. Neurologic, systemic, and local complications were recorded on the basis of clinical follow-up results after each angiographic examination. Events that occurred within 24 hours of angiography were considered to be complications of the procedure. Multivariable analysis was employed to identify patient and procedural factors significantly associated with neurologic complications. RESULTS: Neurologic complications occurred in 522 examinations (2.63%), and 27 of these (0.14%) were strokes with permanent disability. Twelve deaths occurred (0.06%). Access-site hematoma was the most common complication overall (4.2%). Factors independently associated with an increased risk of neurologic complication included the indication of atherosclerotic cerebrovascular disease (odds ratio [OR], 2.494), the indication of subarachnoid hemorrhage (OR, 2.523), and the comorbidity of frequent transient ischemic attack (OR, 1.674). Factors independently associated with a decreased risk of neurologic complication were increasing chronologic year in which the procedure was performed (OR, 0.659 per 5-year interval) and involvement of a trainee in the procedure (OR, 0.710). CONCLUSION: In this review, diagnostic catheter cerebral angiography was found to have relatively low complication rates.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2433060536

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 603

Metadata

Authors
Kaufmann, T. J., Huston, J., Mandrekar, J. N., Schleck, C. D., Thielen, K. R., & Kallmes, D. F.
Venue
Radiology
Published
2007-06
Volume
243
Issue
3
Pages
812-819
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2157312318
Cited by
603
References
9
FWCI
20.83
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Complications of Diagnostic Cerebral Angiography: Evaluation of 19 826 Consecutive Patients1. https://app.cochat.ai/papers/10.1148/radiol.2433060536
The paper
Kaufmann, T. J., Huston, J., Mandrekar, J. N., Schleck, C. D., Thielen, K. R., & Kallmes, D. F. (2007). Complications of Diagnostic Cerebral Angiography: Evaluation of 19 826 Consecutive Patients1. Radiology. https://doi.org/10.1148/radiol.2433060536

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.