Dual-Source CT: Effect of Heart Rate, Heart Rate Variability, and Calcification on Image Quality and Diagnostic Accuracy
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
PURPOSE: To prospectively evaluate the effect of heart rate, heart rate variability, and calcification on dual-source computed tomography (CT) image quality and to prospectively assess diagnostic accuracy of dual-source CT for coronary artery stenosis, by using invasive coronary angiography as the reference standard. MATERIALS AND METHODS: This study had local Ethics Committee approval; all patients gave informed consent. Patients who underwent bypass surgery were excluded; patients with coronary artery stent-grafts were included. One hundred patients (20 women, 80 men; mean age, 62 years +/- 10 [standard deviation]) known to have or suspected of having coronary artery disease underwent dual-source CT and invasive coronary angiography. Image quality was assessed. Accuracy of dual-source CT in depiction or exclusion of significant stenosis (>or=50%) was evaluated on a per-segment and per-patient basis. Effects of heart rate, heart rate variability, and calcification on image quality and accuracy were analyzed by using multivariate regression and were analyzed between subgroups of predictor variables. Simple regression was performed to calculate thresholds for adequate image quality. RESULTS: Mean heart rate was 64.9 beats per minute +/- 13.2, mean variability was 23.6 beats per CT examination +/- 36.2, and mean Agatston score was 786.5 +/- 965.9. Diagnostic image quality was obtained in 90.2% of segments. Sensitivity, specificity, and positive and negative predictive values for the presence of significant stenosis were, respectively, 91.1%, 92.0%, 75.4%, and 97.5% by segment and 100%, 81.5%, 93.6%, and 100% by patient. Image quality was significantly related to heart rate variability (P = .015) and calcification (P < .001); the number of nondiagnostic segments was significantly affected by calcification only. Calcification was the single factor with significant impact on diagnostic accuracy (P = .001). CONCLUSION: While dual-source CT resulted in heart-rate independent image quality, image quality remained prone to heart rate variability and calcification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diagnostic Accuracy of Noninvasive Coronary Angiography Using 64-Slice Spiral Computed Tomography
Raff, G. L., Gallagher, M. J., O’Neill, W. W., & Goldstein, J. A. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.05.056 · Cited by 1,472
First performance evaluation of a dual-source CT (DSCT) system
Flohr, T. G., McCollough, C. H., Bruder, H., Petersilka, M., Gruber, K., Süβ, C., Grasruck, M., Stierstorfer, K., Krauss, B., Raupach, R., et al. (2006) · European Radiology · doi:10.1007/s00330-005-2919-2 · Cited by 1,413
Self-citationQuantification of Obstructive and Nonobstructive Coronary Lesions by 64-Slice Computed Tomography
Leber, A. W., Knez, A., von Ziegler, F., Becker, A., Nikolaou, K., Paul, S., Wintersperger, B., Reiser, M., Becker, C. R., Steinbeck, G., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.03.071 · Cited by 1,109
Mollet, N. R., Cademartiri, F., van Mieghem, C. A. G., Runza, G., McFadden, E. P., Baks, T., Serruys, P. W., Krestin, G. P., & de Feyter, P. J. (2005) · Circulation · doi:10.1161/circulationaha.105.533471 · Cited by 1,018
Accuracy of MSCT coronary angiography with 64-slice technology: first experience
Leschka, S., Alkadhi, H., Plass, A., Desbiolles, L., Grünenfelder, J., Marincek, B., & Wildermuth, S. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi261 · Cited by 960
Achenbach, S. S., Ropers, D., Kuettner, A., Flohr, T. G., Ohnesorge, B. M., Bruder, H., Theessen, H., Karakaya, M., Daniel, W. G., Bautz, W. A., et al. (2006) · European Journal of Radiology · doi:10.1016/j.ejrad.2005.12.017 · Cited by 435
Scheffel, H., Alkadhi, H., Plass, A., Vachenauer, R., Desbiolles, L., Gaemperli, O., Schepis, T., Frauenfelder, T., Schertler, T., Husmann, L., et al. (2006) · European Radiology · doi:10.1007/s00330-006-0474-0 · Cited by 420
Schoepf, U. J., Becker, C. R., Ohnesorge, B. M., & Yucel, E. K. (2004) · Radiology · doi:10.1148/radiol.2321030636 · Cited by 356
Bashore, T. M., Bates, E. R., Berger, P. B., Clark, D. A., Cusma, J. T., Dehmer, G. J., Kern, M. J., Laskey, W. K., O’Laughlin, M. P., Oesterle, S., et al. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01346-8 · Cited by 320
Kuettner, A., Trabold, T., Schroeder, S., Feyer, A., Beck, T., Brueckner, A., Heuschmid, M., Burgstahler, C., Kopp, A. F., & Claussen, C. D. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.05.079 · Cited by 280
Self-citation
Cited by
2013 ESC guidelines on the management of stable coronary artery disease
Task Force Members, Montalescot, G., Sechtem, U., Achenbach, S., Andreotti, F., Arden, C., Budaj, A., Bugiardini, R., Crea, F., Cuisset, T., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht296 · Cited by 4,510
Schuetz, G. M., Zacharopoulou, N. M., Schlattmann, P., & Dewey, M. (2010) · Annals of Internal Medicine · doi:10.7326/0003-4819-152-3-201002020-00008 · Cited by 265
Coronary CT angiography: current status and continuing challenges
Sun, Z., Choo, G. H., & Ng, K. H. (2012) · The British Journal of Radiology · doi:10.1259/bjr/15296170 · Cited by 189
Leschka, S., Stolzmann, P., Desbiolles, L., Baumueller, S., Goetti, R., Schertler, T., Scheffel, H., Plass, A., Falk, V., Feuchtner, G., et al. (2009) · European Radiology · doi:10.1007/s00330-009-1618-9 · Cited by 188
Vavere, A. L., Arbab-Zadeh, A., Rochitte, C. E., Dewey, M., Niinuma, H., Gottlieb, I., Clouse, M. E., Bush, D. E., Hoe, J. W. M., de Roos, A., et al. (2011) · Radiology · doi:10.1148/radiol.11110537 · Cited by 177
Schuetz, G. M., Schlattmann, P., & Dewey, M. (2012) · BMJ · doi:10.1136/bmj.e6717 · Cited by 176
Benz, D. C., Benetos, G., Rampidis, G., von Felten, E., Bakula, A., Sustar, A., Kudura, K., Messerli, M., Fuchs, T. A., Gebhard, C., et al. (2020) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2020.01.002 · Cited by 168
Coronary CT versus MR angiography: the role of MR angiography
Sakuma, H. (2011) · Radiology · doi:10.1148/radiol.10100116 · Cited by 73
Metadata
- Authors
- Brodoefel, H., Burgstahler, C., Tsiflikas, I., Reimann, A., Schroeder, S., Claussen, C. D., Heuschmid, M., & Kopp, A. F.
- Venue
- Radiology
- Published
- 2008-05
- Volume
- 247
- Issue
- 2
- Pages
- 346-355
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2125843124
- Cited by
- 243
- References
- 15
- FWCI
- 23.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.