CoChat

Dual-Source CT: Effect of Heart Rate, Heart Rate Variability, and Calcification on Image Quality and Diagnostic Accuracy

Brodoefel, Harald, Burgstahler, Christof, Tsiflikas, Ilias, Reimann, Anja, Schroeder, Stephen, Claussen, Claus D., Heuschmid, Martin, Kopp, Andreas F. · 2008 · Radiology
Cited by 243

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Abstract

PURPOSE: To prospectively evaluate the effect of heart rate, heart rate variability, and calcification on dual-source computed tomography (CT) image quality and to prospectively assess diagnostic accuracy of dual-source CT for coronary artery stenosis, by using invasive coronary angiography as the reference standard. MATERIALS AND METHODS: This study had local Ethics Committee approval; all patients gave informed consent. Patients who underwent bypass surgery were excluded; patients with coronary artery stent-grafts were included. One hundred patients (20 women, 80 men; mean age, 62 years +/- 10 [standard deviation]) known to have or suspected of having coronary artery disease underwent dual-source CT and invasive coronary angiography. Image quality was assessed. Accuracy of dual-source CT in depiction or exclusion of significant stenosis (>or=50%) was evaluated on a per-segment and per-patient basis. Effects of heart rate, heart rate variability, and calcification on image quality and accuracy were analyzed by using multivariate regression and were analyzed between subgroups of predictor variables. Simple regression was performed to calculate thresholds for adequate image quality. RESULTS: Mean heart rate was 64.9 beats per minute +/- 13.2, mean variability was 23.6 beats per CT examination +/- 36.2, and mean Agatston score was 786.5 +/- 965.9. Diagnostic image quality was obtained in 90.2% of segments. Sensitivity, specificity, and positive and negative predictive values for the presence of significant stenosis were, respectively, 91.1%, 92.0%, 75.4%, and 97.5% by segment and 100%, 81.5%, 93.6%, and 100% by patient. Image quality was significantly related to heart rate variability (P = .015) and calcification (P < .001); the number of nondiagnostic segments was significantly affected by calcification only. Calcification was the single factor with significant impact on diagnostic accuracy (P = .001). CONCLUSION: While dual-source CT resulted in heart-rate independent image quality, image quality remained prone to heart rate variability and calcification.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2472070906

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 243

Metadata

Authors
Brodoefel, H., Burgstahler, C., Tsiflikas, I., Reimann, A., Schroeder, S., Claussen, C. D., Heuschmid, M., & Kopp, A. F.
Venue
Radiology
Published
2008-05
Volume
247
Issue
2
Pages
346-355
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2125843124
Cited by
243
References
15
FWCI
23.65
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.