The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Converting Dose-Length Product to Effective Dose at CT
Open accessAbstract
PURPOSE: To determine effective dose (ED) per unit dose-length product (DLP) conversion factors for computed tomographic (CT) dosimetry. MATERIALS AND METHODS: A CT dosimetry spreadsheet was used to compute patient ED values and corresponding DLP values. The ratio of ED to DLP was determined with 16-section CT scanners from four vendors, as well as with five models from one manufacturer that spanned more than 25 years. ED-to-DLP ratios were determined for 2-cm scan lengths along the patient axis, as well as for typical scan lengths encountered at head and body CT examinations. The dependence of the ratio of ED to DLP on x-ray tube voltage (in kilovolts) was investigated, and the values obtained with the spreadsheet were compared with those obtained by using two other commercially available CT dosimetry software packages. RESULTS: For 2-cm scan lengths, changes in the scan region resulted in differences to ED of a factor of 30, but much lower variation was obtained for typical scan lengths at clinical head and body imaging. Inter- and intramanufacturer differences for ED/DLP were generally small. Representative values of ED/DLP at 120 kV were 2.2 microSv/mGy x cm (head scans), 5.4 microSv/mGy x cm (cervical spine scans), and 18 microSv/mGy x cm (body scans). For head scans, ED/DLP was approximately independent of x-ray tube voltage, but for body scans, the increase from 80 to 140 kV increased the ratio of ED to DLP by approximately 25%. Agreement in ED/DLP data for all three software packages was generally very good, except for cervical spine examinations where one software package determined an ED/DLP ratio that was approximately double that of the other two. CONCLUSION: This article describes a method of providing CT users with a practical and reliable estimate of adult patient EDs by using the DLP displayed on the CT console at the end of any given examination.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Recommendations of the International Commission on Radiological Protection
(1961) · Postgraduate Medical Journal · doi:10.1136/pgmj.37.425.168-b · Cited by 5,862
Cancer risks attributable to low doses of ionizing radiation: Assessing what we really know
Brenner, D. J., Doll, R., Goodhead, D. T., Hall, E. J., Land, C. E., Little, J. B., Lubin, J. H., Preston, D. L., Preston, R. J., Puskin, J. S., et al. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2235592100 · Cited by 1,765
Einstein, A. J., Henzlova, M. J., & Rajagopalan, S. (2007) · JAMA · doi:10.1001/jama.298.3.317 · Cited by 1,410
1990 Recommendations of the International Commission on Radiological Protection.
(1991) · PubMed · Cited by 908
NCRP report no. 93: Ionizing radiation exposure of the population of the United States
Eckelman, W. C. (1988) · International Journal of Radiation Applications and Instrumentation. Part B. Nuclear Medicine and Biology · doi:10.1016/0883-2897(88)90020-7 · Cited by 755
CT scanning: patterns of use and dose
Mettler, F. A., Wiest, P. W., Locken, J. A., & Kelsey, C. A. (2000) · Journal of Radiological Protection · doi:10.1088/0952-4746/20/4/301 · Cited by 664
AAPM/RSNA Physics Tutorial for Residents: Topics in CT: Radiation Dose in CT
McNitt-Gray, M. F. (2002) · RadioGraphics · doi:10.1148/rg.226025128 · Cited by 612
National survey of doses from CT in the UK: 2003
Shrimpton, P. C., Hillier, M. C., Lewis, M. A., & Dunn, M. (2006) · The British Journal of Radiology · doi:10.1259/bjr/93277434 · Cited by 568
National Conference on Dose Reduction in CT, with an Emphasis on Pediatric Patients
Linton, O. W., & Mettler, F. A. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.181.2.1810321 · Cited by 380
CT-Expo - ein neuartiges Programm zur Dosisevaluierung in der CT
Stamm, G., & Nagel, H. D. (2002) · RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · doi:10.1055/s-2002-35937 · Cited by 353
McCollough, C. H., & Schueler, B. A. (2000) · Medical Physics · doi:10.1118/1.598948 · Cited by 291
Hart, D. B., Jones, D., & Wall, B. F. (1994) · OpenGrey (Institut de l'Information Scientifique et Technique) · Cited by 275
Kramer, R., Vieira, J. W., Khoury, H. J., Lima, F. R. A., & Fuelle, D. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/10/301 · Cited by 239
A PC program for estimating organ dose and effective dose values in computed tomography
Kalender, W. A., Schmidt, B., Zankl, M., & Schmidt, M. (1999) · European Radiology · doi:10.1007/s003300050709 · Cited by 231
The Essential Physics of Medical Imaging, 2nd ed.
Ravenel, J. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.180.3.1800596 · Cited by 229
An approach for the estimation of effective radiation dose at CT in pediatric patients.
Huda, W., Atherton, J. V., Ware, D. E., & Cumming, W. A. (1997) · Radiology · doi:10.1148/radiology.203.2.9114097 · Cited by 217
Self-citationDosimetry for optimisation of patient protection in computed tomography
Jessen, K. A., Shrimpton, P. C., Geleijns, J., Panzer, W., & Tosi, G. (1999) · Applied Radiation and Isotopes · doi:10.1016/s0969-8043(98)00024-4 · Cited by 187
Kramer, R. A., Khoury, H. J., Vieira, J. W., Loureiro, E. C. D. M., Lima, V. J. M., Lima, F. R. D. A., & Hoff, G. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/23/001 · Cited by 138
Assessment of a theoretical formalism for dose estimation in CT: an anthropomorphic phantom study
Brix, G., Lechel, U., Veit, R., Truckenbrodt, R., Stamm, G., Coppenrath, E., Griebel, J., & Nagel, H. D. (2004) · European Radiology · doi:10.1007/s00330-004-2267-7 · Cited by 107
Influence of phantom diameter, kVp and scan mode upon computed tomography dose index
Nickoloff, E. L., Dutta, A. K., & Lu, Z. F. (2003) · Medical Physics · doi:10.1118/1.1543149 · Cited by 106
Radiation Exposure in Computed Tomography
Nagel, H. D., & Huda, W. (2002) · Medical Physics · doi:10.1118/1.1496102 · Cited by 88
Self-citation
Cited by
Deak, P. D., Smal, Y., & Kalender, W. A. (2010) · Radiology · doi:10.1148/radiol.10100047 · Cited by 858
Ultrasonography versus Computed Tomography for Suspected Nephrolithiasis
Smith-Bindman, R., Aubin, C., Bailitz, J., Bengiamin, R. N., Camargo, C. A., Corbo, J., Dean, A. J., Goldstein, R. B., Griffey, R. T., Jay, G. D., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1404446 · Cited by 653
Korean Liver Cancer Association, K., & National Cancer Center, N. (2019) · Gut and Liver · doi:10.5009/gnl19024 · Cited by 391
2022 KLCA-NCC Korea practice guidelines for the management of hepatocellular carcinoma
Korean Liver Cancer Association (KLCA) and National Cancer Center (NCC) Korea (2022) · Clinical and Molecular Hepatology · doi:10.3350/cmh.2022.0294 · Cited by 343
Dewey, M., Zimmermann, E., Deissenrieder, F., Laule, M., Dübel, H.-P., Schlattmann, P., Knebel, F., Rutsch, W., & Hamm, B. (2009) · Circulation · doi:10.1161/circulationaha.109.859280 · Cited by 328
Metadata
- Authors
- Huda, W., Ogden, K. M., & Khorasani, M. R.
- Venue
- Radiology
- Published
- 2008-09
- Volume
- 248
- Issue
- 3
- Pages
- 995-1003
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2126269515
- Cited by
- 513
- References
- 22
- FWCI
- 26.04
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.