The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Liver Cirrhosis: Intravoxel Incoherent Motion MR Imaging—Pilot Study
Abstract
PURPOSE: To retrospectively evaluate a respiratory-triggered diffusion-weighted (DW) magnetic resonance (MR) imaging sequence combined with parallel acquisition to allow the calculation of pure molecular-based (D) and perfusion-related (D*, f) diffusion parameters, on the basis of the intravoxel incoherent motion (IVIM) theory, to determine if these parameters differ between patients with cirrhosis and patients without liver fibrosis. MATERIALS AND METHODS: The institutional review board approved this retrospective study; informed consent was waived. IVIM DW imaging was tested on three alkane phantoms, on which the signal-intensity decay curves according to b factors were logarithmically plotted. Ten b factors (0, 10, 20, 30, 50, 80, 100, 200, 400, 800 sec/mm(2)) were used in patients. Patients with documented liver cirrhosis (cirrhotic liver group, n = 12) and patients without chronic liver disease (healthy liver group, n = 25) were included. The mean liver D, D*, and f values were measured and compared with the apparent diffusion coefficient (ADC) computed by using four b values (0, 200, 400, 800 sec/mm(2)). Liver ADC and D, f, and D* parameters were compared between the cirrhotic liver group and healthy liver group. Means were compared by using the Student t test. RESULTS: Signal-intensity decay curves were monoexponential on phantoms and biexponential in patients. In vivo, mean ADC values were significantly higher than D in the healthy liver group (ADC = 1.39 x 10(-3) mm(2)/sec +/- 0.2 [standard deviation] vs D = 1.10 x 10(-3) mm(2)/sec +/- 0.7) and in the cirrhotic liver group (ADC = 1.23 x 10(-3) mm(2)/sec +/- 0.4 vs D = 1.19 x 10(-3) mm(2)/sec +/- 0.5) (P = .03). ADC and D* were significantly reduced in the cirrhotic liver group compared with those in the healthy liver group (respective P values of .03 and .008). CONCLUSION: Restricted diffusion observed in patients with cirrhosis may be related to D* variations, which reflect decreased perfusion, as well as alterations in pure molecular water diffusion in cirrhotic livers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Convergence Properties of the Nelder--Mead Simplex Method in Low Dimensions
Lagarias, J. C., Reeds, J. A., Wright, M. H., & Wright, P. E. (1998) · SIAM Journal on Optimization · doi:10.1137/s1052623496303470 · Cited by 7,447
Wai, C.-T., Greenson, J. K., Fontana, R. J., Kalbfleisch, J. D., Marrero, J. A., Conjeevaram, H. S., & Lok, A. S.-F. (2003) · Hepatology · doi:10.1053/jhep.2003.50346 · Cited by 4,406
An Algorithm for the Grading of Activity in Chronic Hepatitis C
Bedossa, P., & Poynard, T. (1996) · Hepatology · doi:10.1002/hep.510240201 · Cited by 4,088
Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging.
Le Bihan, D., Breton, E., Lallemand, D., Aubin, M. L., Vignaud, J., & Laval-Jeantet, M. (1988) · Radiology · doi:10.1148/radiology.168.2.3393671 · Cited by 3,169
Castéra, L., Vergniol, J., Foucher, J., Le Bail, B., Chanteloup, E., Haaser, M., Darriet, M., Couzigou, P., & de Lédinghen, V. (2005) · Gastroenterology · doi:10.1053/j.gastro.2004.11.018 · Cited by 2,487
The Barcelona approach: Diagnosis, staging, and treatment of hepatocellular carcinoma
Llovet, J. M., Fuster, J., & Bruix, J. (2004) · Liver Transplantation · doi:10.1002/lt.20034 · Cited by 700
Taouli, B., Vilgrain, V., Dumont, E., Daire, J.-L., Fan, B., & Menu, Y. (2003) · Radiology · doi:10.1148/radiol.2261011904 · Cited by 577
Yamada, I., Aung, W., Himeno, Y., Nakagawa, T., & Shibuya, H. (1999) · Radiology · doi:10.1148/radiology.210.3.r99fe17617 · Cited by 519
The capillary network: A link between IVIM and classical perfusion
Bihan, D. L., & Turner, R. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910270116 · Cited by 423
Van Beers, B. E., Leconte, I., Materne, R., Smith, A. M., Jamart, J., & Horsmans, Y. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.3.1760667 · Cited by 321
Perfusion Imaging of the Liver: Current Challenges and Future Goals
Pandharipande, P. V., Krinsky, G. A., Rusinek, H., & Lee, V. S. (2005) · Radiology · doi:10.1148/radiol.2343031362 · Cited by 294
Diffusion-weighted magnetic resonance imaging for the assessment of fibrosis in chronic hepatitis C
Lewin, M., Poujol-Robert, A., Boëlle, P.-Y., Wendum, D., Lasnier, E., Viallon, M., Guéchot, J., Hoeffel, C., Arrivé, L., Tubiana, J.-M., et al. (2007) · Hepatology · doi:10.1002/hep.21747 · Cited by 265
Test liquids for quantitative MRI measurements of self-diffusion coefficient in vivo
Tofts, P. S., Lloyd, D., Clark, C. A., Barker, G. J., Parker, G. J. M., McConville, P., Baldock, C., & Pope, J. M. (2000) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(200003)43:3<368::aid-mrm8>3.0.co;2-b · Cited by 265
Bihan, D. L., Turner, R., & Macfall, J. R. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910100305 · Cited by 228
Abdomen: Diffusion-weighted MR Imaging with Pulse-triggered Single-Shot Sequences
Mürtz, P., Flacke, S., Träber, F., van den Brink, J. S., Gieseke, J., & Schild, H. H. (2002) · Radiology · doi:10.1148/radiol.2241011117 · Cited by 222
Koinuma, M., Ohashi, I., Hanafusa, K., & Shibuya, H. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20344 · Cited by 218
Cirrhosis: Modified Caudate–Right Lobe Ratio
Awaya, H., Mitchell, D. G., Kamishima, T., Holland, G., Ito, K., & Matsumoto, T. (2002) · Radiology · doi:10.1148/radiol.2243011495 · Cited by 196
Ichikawa, T., Haradome, H., Hachiya, J., Nitatori, T., & Araki, T. (1999) · Abdominal Imaging · doi:10.1007/s002619900539 · Cited by 173
Taouli, B. A., Martin, A. J., Qayyum, A., Merriman, R. B., Vigneron, D. B., Yeh, B. M., & Coakley, F. V. (2004) · American Journal of Roentgenology · doi:10.2214/ajr.183.3.1830677 · Cited by 134
Water diffusion compartmentation at high b values in ischemic human brain.
Brugières, P., Thomas, P., Maraval, A., Hosseini, H., Combes, C., Chafiq, A., Ruel, L., Breil, S., Peschanski, M., & Gaston, A. (2004) · PubMed · Cited by 73
Self-citationNoninvasive diagnosis of liver fibrosis by ultrasonic transient elastography (Fibroscan)
Nguyen-Khac, É., & Capron, D. (2006) · European Journal of Gastroenterology & Hepatology · doi:10.1097/01.meg.0000243884.55562.37 · Cited by 72
Moteki, T., Horikoshi, H., Oya, N., Aoki, J., & Endo, K. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10101 · Cited by 53
MR imaging in chronic hepatitis and cirrhosis
Mortelé, K. J., & Ros, P. R. (2002) · Seminars in Ultrasound CT and MRI · doi:10.1016/s0887-2171(02)90030-2 · Cited by 40
Cited by
Diffusion-weighted MR Imaging of the Liver
Taouli, B., & Koh, D.-M. (2010) · Radiology · doi:10.1148/radiol.09090021 · Cited by 810
Intravoxel Incoherent Motion in Body Diffusion-Weighted MRI: Reality and Challenges
Koh, D.-M., Collins, D. J., & Orton, M. R. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.10.5515 · Cited by 527
Clinical intravoxel incoherent motion and diffusion MR imaging: Past, present, and future
Iima, M., & Le Bihan, D. (2016) · Radiology · doi:10.1148/radiol.2015150244 · Cited by 498
What can we see with IVIM MRI?
Le Bihan, D. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2017.12.062 · Cited by 498
Patel, J., Sigmund, E. E., Rusinek, H., Oei, M., Babb, J. S., & Taouli, B. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22081 · Cited by 371
Metadata
- Authors
- Luciani, A., Vignaud, A., Cavet, M., Tran Van Nhieu, J., Mallat, A., Ruel, L., Laurent, A., Deux, J.-F., Brugieres, P., & Rahmouni, A.
- Venue
- Radiology
- Published
- 2008-12
- Volume
- 249
- Issue
- 3
- Pages
- 891-899
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2144472068
- Cited by
- 612
- References
- 23
- FWCI
- 20.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.