CoChat

Endometriosis: Contribution of 3.0-T Pelvic MR Imaging in Preoperative Assessment—Initial Results

Hottat, Nathalie, Larrousse, Caroline, Anaf, Vincent, Noël, Jean-Christophe, Matos, Celso, Absil, Julie, Metens, Thierry · 2009 · Radiology
Cited by 131

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

PURPOSE: To determine the accuracy of 3.0-T pelvic magnetic resonance (MR) imaging in the preoperative assessment of endometriosis and to evaluate colon wall involvement after intrarectal gel administration. MATERIALS AND METHODS: Institutional review board approval for this study was obtained, and each patient gave written informed consent. Forty-one consecutive patients with clinical suspicion of endometriosis underwent pelvic MR imaging at 3.0 T before surgery. Single-shot and high-spatial-resolution axial T2-weighted, sagittal fat-suppressed T2-weighted, and axial fat-suppressed T1-weighted sequences were performed. T2-weighted sequences were repeated after the rectum was filled with ultrasonographic (US) gel. Two blinded readers interpreted images independently. Image quality was scored by using a four-point scale. Detailed mapping of deep endometriosis was performed. Colon wall infiltration was graded (none, serosa, muscularis, submucosa, mucosa). MR imaging results were compared with surgical and pathologic findings. Interobserver agreement was assessed by using kappa statistics. Nonparametric tests were performed to compare colon wall infiltration scores without and those with US gel and between observers. RESULTS: Twenty-seven of 41 patients had deep endometriosis at surgery and histopathologic examination. Sensitivity, specificity, positive and negative predictive values, and accuracy for the diagnosis of deep endometriosis at MR imaging were 96.3% (26 of 27), 100% (14 of 14), 100% (26 of 26), 93.3% (14 of 15), and 97.6% (40 of 41), respectively. kappa Values ranged from 0.65 to 1.0, depending on the location of deep endometriosis. Colon wall infiltration assessment by both readers correlated well with pathologic findings (Spearman coefficient, >0.93), although median wall involvement scores were lower at pathologic examination than for both readers both before (P = .042 and P = .011) and after (P = .079 and P = .011) intrarectal gel filling. CONCLUSION: MR imaging of the pelvis at 3.0 T is accurate in the diagnosis and staging of deep endometriosis for the preoperative assessment of patients clinically suspected of having endometriosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2531082113

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 131

Metadata

Authors
Hottat, N., Larrousse, C., Anaf, V., Noël, J.-C., Matos, C., Absil, J., & Metens, T.
Venue
Radiology
Published
2009-10
Volume
253
Issue
1
Pages
126-134
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W1969413038
Cited by
131
References
13
FWCI
9.73
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Endometriosis: Contribution of 3.0-T Pelvic MR Imaging in Preoperative Assessment—Initial Results. https://app.cochat.ai/papers/10.1148/radiol.2531082113
The paper
Hottat, N., Larrousse, C., Anaf, V., Noël, J.-C., Matos, C., Absil, J., & Metens, T. (2009). Endometriosis: Contribution of 3.0-T Pelvic MR Imaging in Preoperative Assessment—Initial Results. Radiology. https://doi.org/10.1148/radiol.2531082113

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.