The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
MR imaging of intravoxel incoherent motions: application to diffusion and perfusion in neurologic disorders.
Abstract
Molecular diffusion and microcirculation in the capillary network result in a distribution of phases in a single voxel in the presence of magnetic field gradients. This distribution produces a spin-echo attenuation. The authors have developed a magnetic resonance (MR) method to image such intravoxel incoherent motions (IVIMs) by using appropriate gradient pulses. Images were generated at 0.5 T in a high-resolution, multisection mode. Diffusion coefficients measured on images of water and acetone phantoms were consistent with published values. Images obtained in the neurologic area from healthy subjects and patients were analyzed in terms of an apparent diffusion coefficient (ADC) incorporating the effect of all IVIMs. Differences were found between various normal and pathologic tissues. The ADC of in vivo water differed from the diffusion coefficient of pure water. Results were assessed in relation to water compartmentation in biologic tissues (restricted diffusion) and tissue perfusion. Nonuniform slow flow of cerebrospinal fluid appeared as a useful feature on IVIM images. Observation of these motions may significantly extend the diagnostic capabilities of MR imaging.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Diffusion MRI-based tractography has offered exclusive means to map structural connections non-invasively in animal and human brain, and is considered a very useful and powerful technique to unravel the human connectome at meso- and macro-level (Le Bihan et al. 1986; Basser et al. 1994b; Mori et al. 1999; Jones 2008; Jbabdi and Johansen-Berg 2011).”
From Diffusion MRI-based cortical connectome reconstruction: dependency on tractography procedures and neuroanatomical characteristics (2018) · cites this paper as Le Bihan et al. 1986
In the citing paper
“Diffusion-weighted MRI is the only noninvasive method available for mapping fiber architecture of tissue in vivo (Le Bihan et al., 1986; Basser et al., 1994)”
From The role of myelination in measures of white matter integrity: Combination of diffusion tensor imaging and two-photon microscopy of CLARITY intact brains (2017) · cites this paper as Le Bihan et al., 1986
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,239
Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance Experiments
Carr, H. Y., & Purcell, E. M. (1954) · Physical Review · doi:10.1103/physrev.94.630 · Cited by 6,445
Use of the Stimulated Echo in NMR Diffusion Studies
Tanner, J. E. (1970) · The Journal of Chemical Physics · doi:10.1063/1.1673336 · Cited by 1,647
Restricted Self-Diffusion of Protons in Colloidal Systems by the Pulsed-Gradient, Spin-Echo Method
Tanner, J. E., & Stejskal, E. O. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670306 · Cited by 873
Cleveland, G., Chang, D. C., Hazlewood, C. F., & Rorschach, H. E. (1976) · Biophysical Journal · doi:10.1016/s0006-3495(76)85754-2 · Cited by 243
Blood flow imaging with MR: spin-phase phenomena.
von Schulthess, G. K., & Higgins, C. B. (1985) · Radiology · doi:10.1148/radiology.157.3.2997836 · Cited by 193
Self diffusion of water in frog muscle
Tanner, J. E. (1979) · Biophysical Journal · doi:10.1016/s0006-3495(79)85162-0 · Cited by 184
Restricted Diffusion in Biophysical Systems
Cooper, R. L., Chang, D. B., Young, A. C., Martin, C. J., & Ancker‐Johnson, B. (1974) · Biophysical Journal · doi:10.1016/s0006-3495(74)85904-7 · Cited by 181
McCall, D. W., Douglass, D. C., & Anderson, E. W. (1959) · The Journal of Chemical Physics · doi:10.1063/1.1730651 · Cited by 158
NMR Even Echo Rephasing in Slow Laminar Flow
Waluch, V., & Bradley, W. G. (1984) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198408000-00003 · Cited by 146
Cited by
Sorted by citations
Items 401–500 of 1,008
Oppenheim, C. (2000) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.69.2.248 · Cited by 120
Roychowdhury, S., Maldjian, J. A., & Grossman, R. I. (2000) · PubMed Central · Cited by 120
Influence of aging on brain gray and white matter changes assessed by conventional, MT, and DT MRI
Benedetti, B., Charil, A., Rovaris, M., Judica, E., Valsasina, P., Sormani, M. P., & Filippi, M. (2006) · Neurology · doi:10.1212/01.wnl.0000198510.73363.c6 · Cited by 119
Kakite, S., Dyvorne, H., Besa, C., Cooper, N., Facciuto, M. E., Donnerhack, C., & Taouli, B. A. (2014) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24538 · Cited by 119
Automatic clustering of white matter fibers in brain diffusion MRI with an application to genetics
Jin, Y., Shi, Y., Zhan, L., Gutman, B. A., de Zubicaray, G. I., McMahon, K. L., Wright, M. J., Toga, A. W., & Thompson, P. M. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.04.048 · Cited by 119
Montaner, J., Rovira, À., Molina, C. A., Arenillas, J. F., Ribó, M., Chacón, P. M., Monasterio, J., & Álvarez‐Sabín, J. (2003) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/01.wcb.0000100044.07481.97 · Cited by 119
Moore, R. J., Strachan, B., Tyler, D. J., Duncan, K. R., Baker, P. N., Worthington, B. S., Johnson, I. R., & Gowland, P. A. (2000) · Placenta · doi:10.1053/plac.2000.0567 · Cited by 119
Yap, Q. J., Teh, I., Fusar‐Poli, P., Sum, M. Y., Kuswanto, C. N., & Sim, K. (2013) · Journal of Neural Transmission · doi:10.1007/s00702-013-0971-7 · Cited by 122
Parsons, E. C., Does, M. D., & Gore, J. C. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20732 · Cited by 118
Kim, C. K., Park, B. K., Lee, H. M., Kim, S. S., & Kim, E. E. (2008) · American Journal of Roentgenology · doi:10.2214/ajr.07.2924 · Cited by 118
CSF‐suppressed quantitative single‐shot diffusion imaging
Kwong, K. K., McKinstry, R. C., Chien, D., Crawley, A. P., Pearlman, J. D., & Rosen, B. R. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910210120 · Cited by 118
Eis, M., Els, T., & Hoehn‐Berlage, M. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340608 · Cited by 118
Toussaint, J., Southern, J. F., Fuster, V., & Kantor, H. L. (1997) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/01.atv.17.3.542 · Cited by 117
Molko, N., Pappata, S., Mangin, J.-F., Poupon, F., LeBihan, D., Bousser, M.-G., & Chabriat, H. (2002) · Stroke · doi:10.1161/01.str.0000041681.25514.22 · Cited by 116
Myocardial edema: A translational view
David Garcia-dorado, A., Andrés, M., Ruiz‐Meana, M., Inserte, J., & Barba, I. (2012) · Journal of Molecular and Cellular Cardiology · doi:10.1016/j.yjmcc.2012.01.010 · Cited by 116
Diffusion-weighted MRI for monitoring neurovascular interventions
Lövblad, K., Plüschke, W., Remonda, L., Gruber-Wiest, D., Do, D.-D., Barth, A., Kniemeyer, H. W., Bassetti, C. L., Mattle, H. P., & Schroth, G. (2000) · Neuroradiology · doi:10.1007/s002340050032 · Cited by 116
Diffusion-Weighted Magnetic Resonance Imaging in Nonconvulsive Status Epilepticus
Chu, K., Kang, D., Kim, J.-Y., Chang, K. H., & Lee, S. K. (2001) · Archives of Neurology · doi:10.1001/archneur.58.6.993 · Cited by 116
Baur, A., Huber, A., Ertl-Wagner, B. B., Dürr, R., Zysk, S., Arbogast, S., Deimling, M., & Reiser, M. F. (2001) · PubMed Central · Cited by 116
King, M. D., Houseman, J., Roussel, S., van Bruggen, N., Williams, S. R., & Gadian, D. G. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320605 · Cited by 116
Barbieri, S., Donati, O. F., Froehlich, J. M., & Thoeny, H. C. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25765 · Cited by 115
Neeman, M., Freyer, J. P., & Sillerud, L. O. (1990) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(90)90136-w · Cited by 115
Diffusion-weighted imaging of bone marrow: current status
Baur, A., Dietrich, O., & Reiser, M. F. (2003) · European Radiology · doi:10.1007/s00330-003-1873-0 · Cited by 115
Diffusion-weighted MR imaging of the normal human spinal cord in vivo.
Holder, C. A., Muthupillai, R., Mukundan, S., Eastwood, J. D., & Hudgins, P. A. (2000) · PubMed Central · Cited by 115
Diffusion imaging for evaluation of tumor therapies in preclinical animal models
Moffat, B. A., Hall, D. E., Stojanovska, J., McConville, P., Moody, J. B., Chenevert, T. L., Rehemtulla, A., & Ross, B. D. (2004) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-004-0079-z · Cited by 115
Chandarana, H., Kang, S. K., Wong, S., Rusinek, H., Zhang, J. L., Arizono, S., Huang, W. C. W., Melamed, J., Babb, J. S., Suan, E. F., et al. (2012) · Investigative Radiology · doi:10.1097/rli.0b013e31826a0a49 · Cited by 114
Jacobs, M. A., Herskovits, E. H., & Kim, H. S. (2005) · Radiology · doi:10.1148/radiol.2361040312 · Cited by 114
Reichenbach, J. R., Röther, J., Jonetz-Mentzel, L., Herzau, M., Fiala, A., Weiller, C., & Kaiser, W. A. (1999) · PubMed Central · Cited by 114
Zelaya, F. O., Flood, N., Chalk, J. B., Wang, D., Doddrell, D. M., Strugnell, W., Benson, M., Østergaard, L., Semple, J. M., & Eagle, S. (1999) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(98)00192-1 · Cited by 114
Multiparametric MR Imaging of Breast Cancer
Rahbar, H., & Partridge, S. C. (2015) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/j.mric.2015.08.012 · Cited by 113
Mohanty, S., Benjamin, L. A., Majhi, M., Panda, P., Kampondeni, S., Sahu, P. K., Mohanty, A., Mahanta, K. C., Pattnaik, R., Mohanty, R. R., et al. (2017) · mSphere · doi:10.1128/msphere.00193-17 · Cited by 113
The effect of Gibbs ringing artifacts on measures derived from diffusion MRI
Perrone, D., Aelterman, J., Pižurica, A., Jeurissen, B., Philips, W. R., & Leemans, A. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.06.068 · Cited by 118
Apparent diffusion coefficient of intervertebral discs related to matrix composition and integrity
Antoniou, J., Demers, C. N., Beaudoin, G., Goswami, T., Mwale, F., Aebi, M., & Alini, M. (2004) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.02.011 · Cited by 113
High Temporal Resolution Diffusion MRI of Global Cerebral Ischemia and Reperfusion
Pierpaoli, C. M., Alger, J. R., Righini, A., Mattiello, J., Dickerson, R. R., Pres, D. D., Barnett, A. S., & Chiro, G. D. (1996) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199609000-00013 · Cited by 113
Bokacheva, L., Kaplan, J. B., Giri, D. D., Patil, S. N., Gnanasigamani, M. M., Nyman, C. G., Deasy, J. O., Morris, E. A., & Thakur, S. B. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24462 · Cited by 112
Distinctive MRI Features of Pediatric Medulloblastoma Subtypes
Yeom, K. W., Mobley, B. C., Lober, R. M., Andre, J. B., Partap, S., Vogel, H. S., & Barnes, P. D. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9249 · Cited by 112
Yang, Y., Cao, M., Sheng, K., Gao, Y., Chen, A. R., Kamrava, M., Lee, P. P., Agazaryan, N., Lamb, J., Thomas, D. H., et al. (2016) · Medical Physics · doi:10.1118/1.4942381 · Cited by 112
Progress in non-invasive detection of liver fibrosis
Chengxi, L., Li, R., & Zhang, W. (2018) · Cancer Biology and Medicine · doi:10.20892/j.issn.2095-3941.2018.0018 · Cited by 115
Diffusion-weighted imaging differentiates ischemic tissue from traumatized tissue.
Hanstock, C. C., Faden, A. I., Bendall, M. R., & Vink, R. (1994) · Stroke · doi:10.1161/01.str.25.4.843 · Cited by 112
Diffusion tensor imaging in patients with adult chronic idiopathic hydrocephalus
Hattingen, E., Jurcoane, A., Melber, J., Blasel, S., Zanella, F. E., Neumann-Haefelin, T., & Singer, O. C. (2010) · Neurosurgery · doi:10.1227/01.neu.0000367801.35654.ec · Cited by 111
Li, P. M. M. C., Linos, E., Gurgel, R. K., Fischbein, N. J., & Blevins, N. H. (2012) · The Laryngoscope · doi:10.1002/lary.23759 · Cited by 111
Svolos, P., Kousi, E., Kapsalaki, E. Z., Theodorou, K., Fezoulidis, I. V., Kappas, C., & Tsougos, I. (2014) · Cancer Imaging · doi:10.1186/1470-7330-14-20 · Cited by 115
Xu, Y., Wang, X., & Jiang, X.-X. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20979 · Cited by 111
Yoshiura, T., Mihara, F., Ogomori, K., Tanaka, A., Kaneko, K., & Masuda, K. (2002) · Neuroreport · doi:10.1097/00001756-200212030-00026 · Cited by 111
Intracranial epidermoid cysts: diffusion-weighted, FLAIR and conventional MR findings
Hakyemez, B., Aksoy, U., Yıldız, H., & Ergin, N. (2004) · European Journal of Radiology · doi:10.1016/j.ejrad.2004.06.018 · Cited by 111
Optimization of b‐value sampling for diffusion‐weighted imaging of the kidney
Zhang, J. L., Sigmund, E. E., Rusinek, H., Chandarana, H., Storey, P., Chen, Q., & Lee, V. S. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22982 · Cited by 110
Robust and fast nonlinear optimization of diffusion MRI microstructure models
Harms, R., Fritz, F. J., Tobisch, A., Goebel, R., & Roebroeck, A. F. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.04.064 · Cited by 110
Eichert, N., Robinson, E. C., Bryant, K., Jbabdi, S., Jenkinson, M., Li, L., Krug, K., Watkins, K. E., & Mars, R. B. (2020) · eLife · doi:10.7554/elife.53232 · Cited by 113
High-resolution diffusion tensor imaging of the brain stem at 3 T.
Nagae‐Poetscher, L. M., Jiang, H., Wakana, S., Golay, X., van Zijl, P. C. M., & Mori, S. (2004) · PubMed Central · Cited by 110
Ductal Carcinoma in Situ of the Breasts: Review of MR Imaging Features
Greenwood, H. I., Heller, S. L., Kim, S., Sigmund, E. E., Shaylor, S. D., & Moy, L. P. (2013) · Radiographics · doi:10.1148/rg.336125055 · Cited by 109
Consensus-based technical recommendations for clinical translation of renal diffusion-weighted MRI
Ljimani, A., Caroli, A., Laustsen, C., Francis, S., Mendichovszky, I. A., Bane, O., Nery, F., Sharma, K., Pohlmann, A., Dekkers, I. A., et al. (2019) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-019-00790-y · Cited by 109
Reliability of fiber tracking measurements in diffusion tensor imaging for longitudinal study
Danielian, L. E., Iwata, N. K., Thomasson, D. M., & Floeter, M. K. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.08.062 · Cited by 109
Kidney Transplant: Functional Assessment with Diffusion-Tensor MR Imaging at 3T
Lanzman, R. S., Ljimani, A., Pentang, G., Zgoura, P., Zenginli, H., Kröpil, P., Heusch, P., Schek, J., Miese, F. R., Blondin, D., et al. (2012) · Radiology · doi:10.1148/radiol.12112522 · Cited by 109
Rovaris, M., Gallo, A., Valsasina, P., Benedetti, B., Caputo, D., Ghezzi, A., Montanari, E., Sormani, M. P., Bertolotto, A., Mancardi, G., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.10.006 · Cited by 109
Modeling and observation of temperature changes in Vivo using MRI
Young, I., Hand, J. W., Oatridge, A., & Prior, M. V. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320311 · Cited by 109
DWI filtering using joint information for DTI and HARDI
Tristán‐Vega, A., & Aja‐Fernández, S. (2009) · Medical Image Analysis · doi:10.1016/j.media.2009.11.001 · Cited by 108
Ichikawa, S., Motosugi, U., Ichikawa, T., Sano, K., Morisaka, H., & Araki, T. (2012) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.08.004 · Cited by 108
Diffusion-weighted and magnetization transfer imaging of the corpus callosum in Alzheimer’s disease
Hanyu, H., Asano, T., Sakurai, H., Imon, Y., Iwamoto, T., Takasaki, M., Shindo, H., & Abe, K. (1999) · Journal of the Neurological Sciences · doi:10.1016/s0022-510x(99)00135-5 · Cited by 108
Notohamiprodjo, M., Dietrich, O., Horger, W., Horng, A., Helck, A. D., Herrmann, K. A., Reiser, M. F., & Gläser, C. (2010) · Investigative Radiology · doi:10.1097/rli.0b013e3181d83abc · Cited by 107
Approaches for the Integrated Analysis of Structure, Function and Connectivity of the Human Brain
Eickhoff, S. B., & Grefkes, C. (2011) · Clinical EEG and Neuroscience · doi:10.1177/155005941104200211 · Cited by 106
Addressing a systematic vibration artifact in diffusion‐weighted MRI
Gallichan, D., Scholz, J., Bartsch, A., Behrens, T. E. J., Robson, M. D., & Miller, K. L. (2009) · Human Brain Mapping · doi:10.1002/hbm.20856 · Cited by 106
Arterial spin labeling for the measurement of cerebral perfusion and angiography
Jezzard, P., Chappell, M. A., & Okell, T. W. (2017) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1177/0271678x17743240 · Cited by 106
Diffusion Tensor Imaging of the Spinal Cord
Vedantam, A., Jirjis, M. B., Schmit, B. D., Wang, M. C., Ulmer, J. L., & Kurpad, S. N. (2013) · Neurosurgery · doi:10.1227/neu.0000000000000171 · Cited by 106
Clinical presentation and diagnosis of uterine sarcoma, including imaging
Wu, T.-I., Yen, T., & Lai, C. (2011) · Best Practice & Research Clinical Obstetrics & Gynaecology · doi:10.1016/j.bpobgyn.2011.07.002 · Cited by 106
Challenges for molecular neuroimaging with MRI
Lelyveld, V. S., Atanasijevic, T., & Jasanoff, A. (2010) · International Journal of Imaging Systems and Technology · doi:10.1002/ima.20221 · Cited by 106
Multiple quantum filtered23Na NMR spectroscopy of the isolated, perfused rat liver
Colet, J., Bansal, N., Malloy, C. R., & Sherry, A. D. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199906)41:6 · Cited by 17
Deprez, S., Billiet, T., Sunaert, S. G., & Leemans, A. (2013) · Brain Imaging and Behavior · doi:10.1007/s11682-012-9220-1 · Cited by 109
Nicoletti, G., Tonon, C., Lodi, R., Condino, F., Manners, D. N., Malucelli, E., Morelli, M., Novellino, F., Paglionico, S., Lanza, P. L., et al. (2008) · Movement Disorders · doi:10.1002/mds.22279 · Cited by 108
Four Decades of Ischemic Penumbra and Its Implication for Ischemic Stroke
Yang, S.-H., & Liu, R. (2021) · Translational Stroke Research · doi:10.1007/s12975-021-00916-2 · Cited by 111
Fujiyoshi, K., Yamada, M., Nakamura, M., Yamane, J., Katoh, H., Kitamura, K., Kawai, K., Okada, S., Momoshima, S., Toyama, Y., et al. (2007) · Journal of Neuroscience · doi:10.1523/jneurosci.3354-07.2007 · Cited by 105
Diffusion weighted imaging of bone marrow pathologies
Herneth, A. M., Friedrich, K., Weidekamm, C., Schibany, N., Krestan, C. R., Czerny, C., & Kainberger, F. M. (2005) · European Journal of Radiology · doi:10.1016/j.ejrad.2005.03.031 · Cited by 105
Tsekos, N. V., Zhang, F., Merkle, H., Nagayama, M., ladecola, C., & Kim, S. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390409 · Cited by 105
MR Imaging: Brief Overview and Emerging Applications
Jacobs, M. A., Ibrahim, T. S., & Ouwerkerk, R. (2007) · Radiographics · doi:10.1148/rg.274065115 · Cited by 105
Noninvasive temperature imaging using diffusion MRI
Delannoy, J., Chen, C., Turner, R., Levin, R. L., & Bihan, D. L. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910190224 · Cited by 105
Glenn, O. A., Henry, R. G., Berman, J., Chang, P. C., Miller, S. P., Vigneron, D. B., & Barkovich, A. J. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10420 · Cited by 105
Bisdas, S., Koh, T. S., Roder, C., Braun, C., Schittenhelm, J., Ernemann, U., & Klose, U. (2013) · Neuroradiology · doi:10.1007/s00234-013-1229-7 · Cited by 104
Ginat, D. T., Mangla, R., Yeaney, G. A., Johnson, M. D., & EKHOLM, S. E. (2012) · American Journal of Roentgenology · doi:10.2214/ajr.11.7424 · Cited by 104
Functional MR imaging of the female pelvis
Koyama, T., & Togashi, K. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20913 · Cited by 104
Intravoxel incoherent motion MRI as a means to measure in vivo perfusion: A review of the evidence
Federau, C. (2017) · NMR in Biomedicine · doi:10.1002/nbm.3780 · Cited by 104
Citation Classics in Radiology Journals: The 100 Top-Cited Articles, 1945–2012
Yoon, D. Y., Yun, E. J., Ku, Y. J., Baek, S., Lim, K. J., Seo, Y. L., & Yie, M. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.10489 · Cited by 104
A pitfall in the reconstruction of fibre ODFs using spherical deconvolution of diffusion MRI data
Parker, G. D., Marshall, D., Rosin, P. L., Drage, N. A., Richmond, S., & Jones, D. K. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.10.022 · Cited by 104
Wall, C. J., Kendall, E. J., & Obenaus, A. (2000) · PubMed Central · Cited by 104
Katayama, M., Masui, T., Kobayashi, S., Ito, T., Sakahara, H., Nozaki, A., & Kabasawa, H. (2002) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200203000-00015 · Cited by 103
Notohamiprodjo, M., Chandarana, H., Mikheev, A. V., Rusinek, H., Grinstead, J. W., Feiweier, T., Raya, J. G., Lee, V. S., & Sigmund, E. E. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25245 · Cited by 103
Yoon, J. H., Lee, J. M., Yu, M. H., Kiefer, B., Han, J. K., & Choi, B. I. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24158 · Cited by 103
Lee, K. C., Bradley, D., Hussain, M., Meyer, C. R., Chenevert, T. L., Jacobson, J. A., Johnson, T. D., Galbán, C. J., Rehemtulla, A., Pienta, K. J., et al. (2007) · Neoplasia · doi:10.1593/neo.07954 · Cited by 103
Silva, A. C., Williams, D. S., & Koretsky, A. P. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380211 · Cited by 103
DTI segmentation by statistical surface evolution
Lenglet, C., Rousson, M., & Rachid Deriche, B. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.873299 · Cited by 106
Diffusion, confusion and functional MRI
Bihan, D. L. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.09.058 · Cited by 111
Budinger, T. F., & Bird, M. D. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.01.067 · Cited by 102
Evidence for exercise-related plasticity in functional and structural neural network connectivity
Won, J., Callow, D. D., Pena, G. S., Gogniat, M. A., Kommula, Y., Arnold-Nedimala, N. A., Jordan, L. S., & Smith, J. C. (2021) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2021.10.013 · Cited by 109
Nilsen, L. B., Fangberget, A., Geier, O. M., Olsen, D. R., & Seierstad, T. (2010) · Acta Oncologica · doi:10.3109/02841861003610184 · Cited by 102
Billiet, T., Mädler, B., D'Arco, F., Peeters, R., Deprez, S., Plasschaert, E., Leemans, A., Zhang, H., den Bergh, B. V., Vandenbulcke, M., et al. (2014) · NeuroImage: Clinical · doi:10.1016/j.nicl.2014.04.005 · Cited by 101
Diffusion-weighted MRI in Crohn's disease: Current status and recommendations
Dohan, A. J. J., Taylor, S. A., Hoeffel, C. C., Barret, M., Allez, M., Dautry, R., Zappa, M., Savoye‐Collet, C., Dray, X., Boudiaf, M., et al. (2016) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25325 · Cited by 101
Does IVIM measure classical perfusion?
Henkelman, R. M. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160313 · Cited by 101
Norris, D. G. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1072 · Cited by 101
Assaf, Y., & Cohen, Y. (1999) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199910)12:6 · Cited by 104
Gill, R., Sibson, N. R., Hatfield, R., Burdett, N. G., Carpenter, T. A., Häll, L., & Pickard, J. D. (1995) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1995.1 · Cited by 101
Guzman, R. G., Barth, A., Lövblad, K., El‐Koussy, M., Weis, J., Schroth, G., & Seiler, R. W. (2002) · Journal of neurosurgery · doi:10.3171/jns.2002.97.5.1101 · Cited by 101
Temporal and spatial assessment of normal cerebrospinal fluid dynamics with MR imaging
Henry–Feugeas, M.-C., Idy-Peretti, I., Blanchet, B., Hassine, D., Zannoli, G., & Schouman‐Claeys, E. (1993) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(93)90238-9 · Cited by 101
Systematic Review of Diffusion and Perfusion Imaging in Acute Ischemic Stroke
Keir, S. L., & Wardlaw, J. M. (2000) · Stroke · doi:10.1161/01.str.31.11.2723 · Cited by 101
Metadata
- Authors
- Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M.
- Affiliations
- Centre hospitalier national d'ophtalmologie des Quinze-Vingts (FR)
- Venue
- Radiology
- Published
- 1986-11
- Volume
- 161
- Issue
- 2
- Pages
- 401-407
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2129841144
- Cited by
- 3,912
- References
- 13
- Citations by year
- 2026: 85 · 2025: 118 · 2024: 128 · 2023: 158 · 2022: 151 · 2021: 201 · 2020: 175 · 2019: 157 · 2018: 187 · 2017: 199 · 2016: 167 · 2015: 170 · 2014: 166 · 2013: 160 · 2012: 127
- FWCI
- 11.77
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Radiology (publishedVersion)
- PubMed (publishedVersion)
- HAL (submittedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced Neuroimaging Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › NMR spectroscopy and applications
- Keywords
- intravoxel incoherent motion, diffusion MRI, perfusion MRI, apparent diffusion coefficient, restricted diffusion, capillary microcirculation, cerebrospinal fluid flow, neurological disorders, magnetic resonance imaging
- MeSH terms
- Astrocytoma, Brain Diseases, Brain Neoplasms, Cerebrovascular Circulation, Humans, Hydrocephalus, Magnetic Resonance Spectroscopy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review