The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
MR imaging of intravoxel incoherent motions: application to diffusion and perfusion in neurologic disorders.
Abstract
Molecular diffusion and microcirculation in the capillary network result in a distribution of phases in a single voxel in the presence of magnetic field gradients. This distribution produces a spin-echo attenuation. The authors have developed a magnetic resonance (MR) method to image such intravoxel incoherent motions (IVIMs) by using appropriate gradient pulses. Images were generated at 0.5 T in a high-resolution, multisection mode. Diffusion coefficients measured on images of water and acetone phantoms were consistent with published values. Images obtained in the neurologic area from healthy subjects and patients were analyzed in terms of an apparent diffusion coefficient (ADC) incorporating the effect of all IVIMs. Differences were found between various normal and pathologic tissues. The ADC of in vivo water differed from the diffusion coefficient of pure water. Results were assessed in relation to water compartmentation in biologic tissues (restricted diffusion) and tissue perfusion. Nonuniform slow flow of cerebrospinal fluid appeared as a useful feature on IVIM images. Observation of these motions may significantly extend the diagnostic capabilities of MR imaging.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Diffusion MRI-based tractography has offered exclusive means to map structural connections non-invasively in animal and human brain, and is considered a very useful and powerful technique to unravel the human connectome at meso- and macro-level (Le Bihan et al. 1986; Basser et al. 1994b; Mori et al. 1999; Jones 2008; Jbabdi and Johansen-Berg 2011).”
From Diffusion MRI-based cortical connectome reconstruction: dependency on tractography procedures and neuroanatomical characteristics (2018) · cites this paper as Le Bihan et al. 1986
In the citing paper
“Diffusion-weighted MRI is the only noninvasive method available for mapping fiber architecture of tissue in vivo (Le Bihan et al., 1986; Basser et al., 1994)”
From The role of myelination in measures of white matter integrity: Combination of diffusion tensor imaging and two-photon microscopy of CLARITY intact brains (2017) · cites this paper as Le Bihan et al., 1986
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,239
Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance Experiments
Carr, H. Y., & Purcell, E. M. (1954) · Physical Review · doi:10.1103/physrev.94.630 · Cited by 6,445
Use of the Stimulated Echo in NMR Diffusion Studies
Tanner, J. E. (1970) · The Journal of Chemical Physics · doi:10.1063/1.1673336 · Cited by 1,647
Restricted Self-Diffusion of Protons in Colloidal Systems by the Pulsed-Gradient, Spin-Echo Method
Tanner, J. E., & Stejskal, E. O. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670306 · Cited by 873
Cleveland, G., Chang, D. C., Hazlewood, C. F., & Rorschach, H. E. (1976) · Biophysical Journal · doi:10.1016/s0006-3495(76)85754-2 · Cited by 243
Blood flow imaging with MR: spin-phase phenomena.
von Schulthess, G. K., & Higgins, C. B. (1985) · Radiology · doi:10.1148/radiology.157.3.2997836 · Cited by 193
Self diffusion of water in frog muscle
Tanner, J. E. (1979) · Biophysical Journal · doi:10.1016/s0006-3495(79)85162-0 · Cited by 184
Restricted Diffusion in Biophysical Systems
Cooper, R. L., Chang, D. B., Young, A. C., Martin, C. J., & Ancker‐Johnson, B. (1974) · Biophysical Journal · doi:10.1016/s0006-3495(74)85904-7 · Cited by 181
McCall, D. W., Douglass, D. C., & Anderson, E. W. (1959) · The Journal of Chemical Physics · doi:10.1063/1.1730651 · Cited by 158
NMR Even Echo Rephasing in Slow Laminar Flow
Waluch, V., & Bradley, W. G. (1984) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198408000-00003 · Cited by 146
Cited by
Sorted by citations
Items 101–200 of 1,008
Lansberg, M. G., Thijs, V., O’Brien, M. W., Ali, J., de Crespigny, A. J., Tong, D., Moseley, M. E., & Albers, G. W. (2001) · PubMed Central · Cited by 298
MACDONALD, C., Dikranian, K. T., SONG, S., Bayly, P. V., HOLTZMAN, D., & BRODY, D. (2007) · Experimental Neurology · doi:10.1016/j.expneurol.2007.01.035 · Cited by 300
Sorensen, A. G., Wu, O., Copen, W. A., Davis, T. L., González, R., Koroshetz, W. J., Reese, T. G., Rosen, B. R., Wedeen, V. J., & Weisskoff, R. M. (1999) · Radiology · doi:10.1148/radiology.212.3.r99se24785 · Cited by 297
ADC Measurement of Abdominal Organs and Lesions Using Parallel Imaging Technique
Yoshikawa, T., Kawamitsu, H., Mitchell, D. G., Ohno, Y., Ku, Y., Seo, Y., Fujii, M., & Sugimura, K. (2006) · American Journal of Roentgenology · doi:10.2214/ajr.05.0778 · Cited by 296
Intravoxel Incoherent Motion Perfusion MR Imaging: A Wake-Up Call
Bihan, D. L. (2008) · Radiology · doi:10.1148/radiol.2493081301 · Cited by 303
Conturo, T. E., McKinstry, R. C., Akbudak, E., & Robinson, B. H. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350319 · Cited by 293
Bihan, D. L., Turner, R., MOONEN, C. T. W., & Pekar, J. J. (1991) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880010103 · Cited by 289
Partridge, S. C., Zhang, Z., Newitt, D. C., Gibbs, J., Chenevert, T. L., Rosen, M. A., Bolan, P. J., Marques, H. S., Romanoff, J., Cimino, L., et al. (2018) · Radiology · doi:10.1148/radiol.2018180273 · Cited by 287
Contrast agents and cerebral hemodynamics
Rosen, B. R., Belliveau, J. W., Buchbinder, B. R., McKinstry, R. C., Porkka, L., Kennedy, D. N., NEUDER, M., Fisel, C. R., Aronen, H. J., Kwong, K. K., et al. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910190216 · Cited by 287
Andreou, A., Koh, D., Collins, D. J., Blackledge, M., Wallace, T., Leach, M. O., & Orton, M. R. (2012) · European Radiology · doi:10.1007/s00330-012-2604-1 · Cited by 286
Malayeri, A. A., Khouli, R. H. E., Zaheer, A., Jacobs, M. A., Corona‐Villalobos, C. P., Kamel, I. R., & Macura, K. J. (2011) · Radiographics · doi:10.1148/rg.316115515 · Cited by 286
Water diffusion, T2, and compartmentation in frog sciatic nerve
Peled, S., Cory, D. G., Raymond, S. A., Kirschner, D. A., & Jolesz, F. A. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5 · Cited by 193
Harsan, L. A., Poulet, P., Guignard, B., Steibel, J., Parizel, N., de Sousa, P. L., Boehm, N., Grucker, D., & Ghandour, M. S. (2006) · Journal of Neuroscience Research · doi:10.1002/jnr.20742 · Cited by 295
Lee, S., Kim, D. I., Kim, J., Kim, D. J., Kim, H. D., Kim, D. S., & Mori, S. (2005) · Radiographics · doi:10.1148/rg.251045085 · Cited by 284
Diffusion Weighting by the Trace of the Diffusion Tensor within a Single Scan
Mori, S., & van Zijl, P. C. M. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330107 · Cited by 280
Counsell, S. J., Edwards, A. D., Chew, A. T. M., Anjari, M., Dyet, L. E., Srinivasan, L., Boardman, J. P., Allsop, J. M., Hajnal, J. V., Rutherford, M., et al. (2008) · Brain · doi:10.1093/brain/awn268 · Cited by 279
Bogner, W., Gruber, S., Pinker, K., Grabner, G., Stadlbauer, A., Weber, M., Moser, E., Helbich, T. H., & Trattnig, S. (2009) · Radiology · doi:10.1148/radiol.2532081718 · Cited by 278
A Model-Based Method for Retrospective Correction of Geometric Distortions in Diffusion-Weighted EPI
Andersson, J., & Skare, S. T. (2002) · NeuroImage · doi:10.1006/nimg.2001.1039 · Cited by 273
Bulakbaşı, N., Kocaoğlu, M., Örs, F., Tayfun, C., & Üçöz, T. (2003) · PubMed Central · Cited by 270
Cohen, Y., & Assaf, Y. (2002) · NMR in Biomedicine · doi:10.1002/nbm.778 · Cited by 269
Brunberg, J. A., Chenevert, T. L., McKeever, P. E., Ross, D. A., Junck, L., Muraszko, K. M., Dauser, R., Pipe, J. G., & Betley, A. T. (1995) · PubMed Central · Cited by 269
Diffusion-weighted Imaging Improves the Diagnostic Accuracy of Conventional 3.0-T Breast MR Imaging
Khouli, R. H. E., Jacobs, M. A., Mezban, S. D., Huang, P., Kamel, I. R., Macura, K. J., & Bluemke, D. A. (2010) · Radiology · doi:10.1148/radiol.10091367 · Cited by 267
Kozłowski, P., Chang, S. D., Jones, E. C., Berean, K. W., Chen, H., & Goldenberg, S. L. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20626 · Cited by 267
Diffusion-weighted MR imaging in normal human brains in various age groups.
Helenius, J., Soinne, L., Perkiö, J., Salonen, O. L. M., Kangasmäki, A., Kaste, M., Carano, R. A. D., Aronen, H. J., & Tatlisumak, T. (2002) · PubMed Central · Cited by 267
The Connectome Mapper: An Open-Source Processing Pipeline to Map Connectomes with MRI
Daducci, A., Gerhard, S., Griffa, A., Lemkaddem, A., Cammoun, L., Gigandet, X., Meuli, R. A., Hagmann, P., & Thiran, J. (2012) · PLoS ONE · doi:10.1371/journal.pone.0048121 · Cited by 275
Nanoscale temperature measurements using non-equilibrium Brownian dynamics of a levitated nanosphere
Millen, J., Deesuwan, T., Barker, P. F., & Anders, J. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2014.82 · Cited by 265
White, N. S., Leergaard, T. B., D'Arceuil, H. E., Bjaalie, J. G., & Dale, A. M. (2012) · Human Brain Mapping · doi:10.1002/hbm.21454 · Cited by 266
Changes in water diffusion due to Wallerian degeneration in peripheral nerve
Beaulieu, C., Does, M. D., Snyder, R. E., & Allen, P. S. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360419 · Cited by 263
Lee, P., Duong, T. Q., Yang, G., Iadecola, C., & Kim, S. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1107 · Cited by 263
Lemke, A., Laun, F. B., Simon, D., Stieltjes, B., & Schad, L. R. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22565 · Cited by 262
Visualization of image data from cells to organisms
Walter, T., Shattuck, D. W., Baldock, R., Bastin, M. E., Carpenter, A. E., Duce, S., Ellenberg, J., Fraser, A. N., Hamilton, N., Pieper, S., et al. (2010) · Nature Methods · doi:10.1038/nmeth.1431 · Cited by 261
Limits to anatomical accuracy of diffusion tractography using modern approaches
Schilling, K. G., Nath, V., Hansen, C., Parvathaneni, P., Blaber, J., Gao, Y., Neher, P., Aydogan, D. B., Shi, Y., Ocampo-Pineda, M., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.10.029 · Cited by 260
Tamada, T., Sone, T., Jo, Y., Toshimitsu, S., Yamashita, T., Yamamoto, A., Tanimoto, D., & Ito, K. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21503 · Cited by 258
Knight, R. A., Dereski, M. O., Helpern, J. A., Ordidge, R. J., & Chopp, M. (1994) · Stroke · doi:10.1161/01.str.25.6.1252 · Cited by 258
MR diffusion imaging of cerebral infarction in humans.
(1992) · PubMed Central · Cited by 258
Oouchi, H., Yamada, K., Sakai, K., Kizu, O., Kubota, T., Ito, H., & Nishimura, T. (2007) · American Journal of Neuroradiology · doi:10.3174/ajnr.a0488 · Cited by 256
COMMIT: Convex Optimization Modeling for Microstructure Informed Tractography
Daducci, A., Dal Palu, A., Lemkaddem, A., & Thiran, J.-P. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2352414 · Cited by 255
Wozniak, J. R., & Lim, K. O. (2006) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2006.06.003 · Cited by 257
Synthesized b0 for diffusion distortion correction (Synb0-DisCo)
Schilling, K. G., Blaber, J. A., Huo, Y., Newton, A. T., Hansen, C. B., Nath, V., Shafer, A. T., Williams, O. A., Resnick, S. M., Rogers, B. P., et al. (2019) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2019.05.008 · Cited by 269
White, N. S., McDonald, C. R., Niky, F., Kuperman, J., Karow, D. S., Schenker-Ahmed, N. M., Bartsch, H., Rakow‐Penner, R., Holland, D., Shabaik, A. S., et al. (2014) · Cancer Research · doi:10.1158/0008-5472.can-13-3534 · Cited by 255
Thompson, P. M., Hayashi, K. M., Dutton, R. A., Chiang, M., Leow, A., Sowell, E. R., de Zubicaray, G. I., Becker, J. T., López, O. L., Aizenstein, H. J., et al. (2007) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1379.017 · Cited by 259
Advancements in MR Imaging of the Prostate: From Diagnosis to Interventions
Bonekamp, D., Jacobs, M. A., Khouli, R. H. E., Stoianovici, D. S., & Macura, K. J. (2011) · Radiographics · doi:10.1148/rg.313105139 · Cited by 250
Lenglet, C., Rousson, M., Rachid Deriche, B., & Faugeras, O. D. (2006) · Journal of Mathematical Imaging and Vision · doi:10.1007/s10851-006-6897-z · Cited by 248
Pavuluri, M. N., Yang, S., Kamineni, K., Passarotti, A. M., Srinivasan, G., Harral, E. M., Sweeney, J. A., & Zhou, X. J. (2009) · Biological Psychiatry · doi:10.1016/j.biopsych.2008.10.015 · Cited by 246
Issa, B. A. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10139 · Cited by 244
Taoka, T., & Naganawa, S. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26892 · Cited by 244
Beaulieu, C., & Allen, P. S. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320506 · Cited by 240
Rutherford, M., Counsell, S. J., Allsop, J. M., Boardman, J. P., Kapellou, O., Larkman, D. J., Hajnal, J. V., Edwards, A. D., & Cowan, F. M. (2004) · PEDIATRICS · doi:10.1542/peds.2004-0222 · Cited by 240
Diffusion‐weighted interleaved echo‐planar imaging with a pair of orthogonal navigator echoes
Butts, K., de Crespigny, A. J., Pauly, J. M., & Moseley, M. E. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350518 · Cited by 239
The b matrix in diffusion tensor echo‐planar imaging
Mattiello, J., Basser, P. J., & Bihan, D. L. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370226 · Cited by 238
Asao, C., Korogi, Y., Kitajima, M., Hirai, T., Baba, Y., Makino, K., Kochi, M., Morishita, S., & Yamashita, Y. (2005) · PubMed Central · Cited by 237
Samartzis, L., Dima, D., Fusar‐Poli, P., & Kyriakopoulos, M. (2014) · Journal of Neuroimaging · doi:10.1111/j.1552-6569.2012.00779.x · Cited by 236
Yang, D., Korogi, Y., Sugahara, T., Kitajima, M., Shigematsu, Y., Liang, L., Ushio, Y., & Takahashi, M. (2002) · Neuroradiology · doi:10.1007/s00234-002-0816-9 · Cited by 236
Diffusion tensor imaging of the developing mouse brain
Mori, S., Itoh, R., Zhang, J., Kaufmann, W. E., van Zijl, P. C. M., Solaiyappan, M., & Yarowsky, P. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1155 · Cited by 236
Diffusion-weighted MRI in cervical cancer
McVeigh, P. Z., Syed, A., Milosevic, M., Fyles, A., & Haider, M. A. (2008) · European Radiology · doi:10.1007/s00330-007-0843-3 · Cited by 235
Røhl, L., Østergaard, L., Simonsen, C. Z., Vestergaard‐Poulsen, P., Andersen, G., Sakoh, M., Bihan, D. L., & Gyldensted, C. (2001) · Stroke · doi:10.1161/01.str.32.5.1140 · Cited by 235
Descoteaux, M., Angelino, E. L., Fitzgibbons, S., & Rachid Deriche, B. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20948 · Cited by 235
Identification of Major Ischemic Change
Barber, P. A., Darby, D., Desmond, P. M., Gerraty, R. P., Yang, Q., Li, T., Jolley, D., Donnan, G. A., Tress, B. M., & Davis, S. M. (1999) · Stroke · doi:10.1161/01.str.30.10.2059 · Cited by 234
Mean diffusivity and fractional anisotropy histograms of patients with multiple sclerosis.
Cercignani, M., Inglese, M., Pagani, E., Comi, G., & Filippi, M. (2001) · PubMed Central · Cited by 234
Caprihan, A., & Fukushima, E. (1990) · Physics Reports · doi:10.1016/0370-1573(90)90046-5 · Cited by 234
Cohen, M. S., & Weisskoff, R. M. (1991) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(91)90094-3 · Cited by 234
Dauguet, J., Peled, S., Berezovskii, V., Delzescaux, T., Warfield, S. K., Born, R., & Westin, C.-F. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.04.067 · Cited by 233
Imaging structural and functional brain networks in temporal lobe epilepsy
Bernhardt, B. C., Hong, S., Bernasconi, A., & Bernasconi, N. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00624 · Cited by 244
Burdette, J. H., Elster, A. D., & Ricci, P. E. (1999) · Radiology · doi:10.1148/radiology.212.2.r99au36333 · Cited by 232
Quantitative diffusion tensor imaging in cerebral palsy due to periventricular white matter injury
Thomas, B., Eyssen, M., Peeters, R. R., Molenaers, G., Hecke, P. V., Cock, P. D., & Sunaert, S. G. (2005) · Brain · doi:10.1093/brain/awh600 · Cited by 230
Holzapfel, K., Duetsch, S., Fauser, C., Eiber, M., Rummeny, E. J., & Gaa, J. (2008) · European Journal of Radiology · doi:10.1016/j.ejrad.2008.09.034 · Cited by 228
Differentiation of Pancreas Carcinoma From Healthy Pancreatic Tissue Using Multiple b-Values
Lemke, A., Laun, F. B., Klau, M., Re, T. J., Simon, D., Delorme, S., Schad, L. R., & Stieltjes, B. (2009) · Investigative Radiology · doi:10.1097/rli.0b013e3181b62271 · Cited by 228
Guðbjartsson, H., Maier, S. E., Mulkern, R. V., Mórocz, I. Á., Patz, S., & Jolesz, F. A. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360403 · Cited by 228
Demir, A., Ries, M. G., Moonen, C. T. W., Vital, J.-M., Dehais, J., Arné, P., Caillé, J., & Dousset, V. (2003) · Radiology · doi:10.1148/radiol.2291020658 · Cited by 226
Bihan, D. L., Turner, R., & MacFall, J. R. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910100305 · Cited by 225
Barajas, R., Rubenstein, J. L., Chang, J. S., Hwang, J., & Cha, S. (2009) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1750 · Cited by 225
Intravoxel incoherent motion imaging of tumor microenvironment in locally advanced breast cancer
Sigmund, E. E., Cho, G. Y., Kim, S., Finn, M. E., Moccaldi, M., Jensen, J. H., Sodickson, D. K., Goldberg, J. D., Formenti, S. C., & Moy, L. P. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22740 · Cited by 223
Barajas, R., Phillips, J. J., Parvataneni, R., Molinaro, A. M., Essock-Burns, E., Bourne, G., Parsa, A., Aghi, M. K., McDermott, M. W., Berger, M. S., et al. (2012) · Neuro-Oncology · doi:10.1093/neuonc/nos128 · Cited by 223
Magnetic resonance thermometry: Methodology, pitfalls and practical solutions
Winter, L., Oberacker, E., Paul, K., Ji, Y., Oezerdem, C., Ghadjar, P., Thieme, A. H., Budach, V., Wust, P., & Niendorf, T. (2015) · International Journal of Hyperthermia · doi:10.3109/02656736.2015.1108462 · Cited by 223
Diffusion MRI of cancer: From low to high b‐values
Tang, L., & Zhou, X. J. (2018) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26293 · Cited by 223
Assaf, Y., & Cohen, Y. (1998) · Journal of Magnetic Resonance · doi:10.1006/jmre.1997.1313 · Cited by 222
Plewes, D. B., & Kucharczyk, W. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23642 · Cited by 222
Feature-Based Fusion of Medical Imaging Data
Calhoun, V. D., & Adalı, T. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2008.923773 · Cited by 222
Multimodality Brain Tumor Imaging: MR Imaging, PET, and PET/MR Imaging
Fink, J. R., Muzi, M., Peck, M., & Krohn, K. A. (2015) · Journal of Nuclear Medicine · doi:10.2967/jnumed.113.131516 · Cited by 230
Relationship between bone marrow cellularity and apparent diffusion coefficient
Nonomura, Y., Yasumoto, M., Yoshimura, R., Haraguchi, K., Ito, S., Akashi, T., & Ohashi, I. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1105 · Cited by 220
Intravoxel incoherent motion imaging using steady‐state free precession
Bihan, D. L. (1988) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910070312 · Cited by 218
In utero tractography of fetal white matter development
Kasprian, G. J., Brugger, P. C., Weber, M., Krššák, M., Krampl, E., Herold, C., & Prayer, D. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.07.026 · Cited by 218
Functional Magnetic Resonance Imaging Methods
Chen, J. E., & Glover, G. H. (2015) · Neuropsychology Review · doi:10.1007/s11065-015-9294-9 · Cited by 249
Diffusion imaging concepts for clinicians
Neil, J. J. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21087 · Cited by 217
Rovaris, M., Iannucci, G., Falautano, M., Possa, F., Martinelli, V., Comi, G., & Filippi, M. (2002) · Journal of the Neurological Sciences · doi:10.1016/s0022-510x(01)00690-6 · Cited by 216
Koinuma, M., Ohashi, I., Hanafusa, K., & Shibuya, H. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20344 · Cited by 215
Comparison of single‐shot localization methods (steam and press) for In vivo proton NMR spectroscopy
MOONEN, C. T. W., von Kienlin, M., van Zijl, P. C. M., Cohen, J. S., Gillen, J., Daly, P. F., & Wolf, G. L. (1989) · NMR in Biomedicine · doi:10.1002/nbm.1940020506 · Cited by 215
Filippi, M., Iannucci, G., Cercignani, M., Rocca, M. A., Pratesi, A., & Comı, G. (2000) · Archives of Neurology · doi:10.1001/archneur.57.7.1017 · Cited by 215
Chabriat, H., Pappata, S., Poupon, C., Clark, C. A., Vahedi, K., Poupon, F., Mangin, J. F., Pachot-Clouard, M., Jobert, A., Le Bihan, D., et al. (1999) · Stroke · doi:10.1161/01.str.30.12.2637 · Cited by 214
From diffusion‐weighted MRI to anomalous diffusion imaging
Hall, M. G., & Barrick, T. R. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21453 · Cited by 214
Assessing skeletal muscle mass: historical overview and state of the art
Heymsfield, S. B., Adamek, M., González, M. C., Jia, G., & Thomas, D. M. (2014) · Journal of Cachexia Sarcopenia and Muscle · doi:10.1007/s13539-014-0130-5 · Cited by 224
A novel tensor distribution model for the diffusion-weighted MR signal
Jian, B., Vemuri, B. C., Özarslan, E., Carney, P. R., & Mareci, T. H. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.03.074 · Cited by 214
Radiomics strategy for glioma grading using texture features from multiparametric MRI
Tian, Q., Yan, L., Zhang, X., Zhang, X., Hu, Y., Han, Y., Liu, Z., Nan, H., Sun, Q., Sun, Y., et al. (2018) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26010 · Cited by 221
Norris, D. G. (2001) · NMR in Biomedicine · doi:10.1002/nbm.682 · Cited by 213
Multi-centre reproducibility of diffusion MRI parameters for clinical sequences in the brain
Grech‐Sollars, M., Hales, P. W., Miyazaki, K., Raschke, F., Rodriguez, D., Wilson, M., Gill, S. K., Banks, T., Saunders, D. E., Clayden, J. D., et al. (2015) · NMR in Biomedicine · doi:10.1002/nbm.3269 · Cited by 213
Alzheimer disease: new concepts on its neurobiology and the clinical role imaging will play
Jack, C. R. (2012) · Radiology · doi:10.1148/radiol.12110433 · Cited by 211
Fundamental Physics of MR Imaging
Pooley, R. A. (2005) · Radiographics · doi:10.1148/rg.254055027 · Cited by 210
Clinical applications of diffusion tensor imaging
Dong, Q., Welsh, R. C., Chenevert, T. L., Carlos, R. C., Sundgren, P. C., Gomez‐Hassan, D. M., & Mukherji, S. K. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10424 · Cited by 210
Mintorovitch, J., Yang, G., Shimizu, H., Kucharczyk, J. R., Chan, P. H., & Weinstein, P. R. (1994) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1994.40 · Cited by 210
Metadata
- Authors
- Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M.
- Affiliations
- Centre hospitalier national d'ophtalmologie des Quinze-Vingts (FR)
- Venue
- Radiology
- Published
- 1986-11
- Volume
- 161
- Issue
- 2
- Pages
- 401-407
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2129841144
- Cited by
- 3,912
- References
- 13
- Citations by year
- 2026: 85 · 2025: 118 · 2024: 128 · 2023: 158 · 2022: 151 · 2021: 201 · 2020: 175 · 2019: 157 · 2018: 187 · 2017: 199 · 2016: 167 · 2015: 170 · 2014: 166 · 2013: 160 · 2012: 127
- FWCI
- 11.77
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Radiology (publishedVersion)
- PubMed (publishedVersion)
- HAL (submittedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced Neuroimaging Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › NMR spectroscopy and applications
- Keywords
- intravoxel incoherent motion, diffusion MRI, perfusion MRI, apparent diffusion coefficient, restricted diffusion, capillary microcirculation, cerebrospinal fluid flow, neurological disorders, magnetic resonance imaging
- MeSH terms
- Astrocytoma, Brain Diseases, Brain Neoplasms, Cerebrovascular Circulation, Humans, Hydrocephalus, Magnetic Resonance Spectroscopy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review