The DOI matches its Crossref record.
Superparamagnetic iron oxide: clinical application as a contrast agent for MR imaging of the liver.
Abstract
Superparamagnetic iron oxide (ferrite) particles were evaluated as a contrast agent for magnetic resonance (MR) imaging. In this pilot study, doses ranging from 10 to 50 mumol/kg were administered intravenously to 15 patients. Ferrite-enhanced images of the liver obtained with standard pulse sequence techniques significantly increased the number of hepatic lesions detected (P less than .01) and reduced the threshold size for detection to 3 mm (P less than .01). The improved clinical performance of ferrite-enhanced images correlated with significant increases in measured contrast-to-noise ratios (P less than .01). Degradation of superparamagnetic activity and/or clearance of ferrite from the liver was demonstrated as early as 12 hours after injection, suggesting that the lack of chronic toxicity observed in animal studies may be reproduced in humans. These initial clinical results appear to confirm extensive preclinical data indicating that ferrite administered at a dose of 20 mumol/kg has the potential to significantly improve the performance of abdominal MR imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Iron oxide MR contrast agents for molecular and cellular imaging
Bulte, J. W. M., & Kraitchman, D. L. (2004) · NMR in Biomedicine · doi:10.1002/nbm.924 · Cited by 1,500
Multifunctional magnetic nanoparticles for targeted imaging and therapy
MCCARTHY, J., & WEISSLEDER, R. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.014 · Cited by 892
Self-citationde Vries, I. J. M., Lesterhuis, W. J., Barentsz, J. O., Verdijk, P., van Krieken, J. H., Boerman, O. C., Oyen, W. J. G., Bonenkamp, J. J., Boezeman, J. B., Adema, G. J., et al. (2005) · Nature Biotechnology · doi:10.1038/nbt1154 · Cited by 821
Superparamagnetic iron oxide nanoparticles: from preparations to in vivo MRI applications
Qiao, R., Yang, C., & Gao, M. (2009) · Journal of Materials Chemistry · doi:10.1039/b902394a · Cited by 685
Characterization of aqueous dispersions of Fe3O4 nanoparticles and their biomedical applications
Cheng, F.-Y., Su, C.-H., Yang, Y.-S., Yeh, C.-S., Tsai, C.-Y., Wu, C.-L., Wu, M.-T., & Shieh, D.-B. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.03.016 · Cited by 668
Metadata
- Authors
- Stark, D. D., Weissleder, R., Elizondo, G., Hahn, P. F., Saini, S., Todd, L. E., Wittenberg, J., & Ferrucci, J. T.
- Venue
- Radiology
- Published
- 1988-08
- Volume
- 168
- Issue
- 2
- Pages
- 297-301
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2119391942
- Cited by
- 512
- References
- 0
- FWCI
- 10.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Superparamagnetic iron oxide: clinical application as a contrast agent for MR imaging of the liver. https://app.cochat.ai/papers/10.1148/radiology.168.2.3393649
- The paper
- Stark, D. D., Weissleder, R., Elizondo, G., Hahn, P. F., Saini, S., Todd, L. E., Wittenberg, J., & Ferrucci, J. T. (1988). Superparamagnetic iron oxide: clinical application as a contrast agent for MR imaging of the liver. Radiology. https://doi.org/10.1148/radiology.168.2.3393649
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.