Heart wall motion: improved method of spatial modulation of magnetization for MR imaging.
The DOI matches its Crossref record.
Abstract
A previously reported method of using magnetic resonance (MR) imaging to study heart wall motion involves a pair of nonselective radio-frequency (RF) pulses, separated by a magnetic field gradient pulse, prior to imaging; this produces images with a regular pattern of stripes that move with the heart wall and that have a sinusoidal intensity profile. It is demonstrated in this study that the substitution of more RF pulses, with their relative amplitudes distributed according to the binomial sequence, results in sharper stripes. This permits the use of a two-dimensional grid of stripes for more detailed studies of heart wall motion and provides a unique method of analyzing regional ventricular myocardial strain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Deformable models in medical image analysis: a survey
McInerney, T., & Terzopoulos, D. (1996) · Medical Image Analysis · doi:10.1016/s1361-8415(96)80007-7 · Cited by 1,913
Shear wave elasticity imaging: a new ultrasonic technology of medical diagnostics
Sarvazyan, A. P., Rudenko, O. V., Swanson, S. D., Fowlkes, J. B., & Emelianov, S. Y. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00110-0 · Cited by 1,727
Three-dimensional modeling for functional analysis of cardiac images, a review
Frangi, A. F., Niessen, W. J., & Viergever, M. A. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.906421 · Cited by 533
DENSE: Displacement Encoding with Stimulated Echoes in Cardiac Functional MRI
Aletras, A. H., Ding, S., Balaban, R. S., & Wen, H. (1999) · Journal of Magnetic Resonance · doi:10.1006/jmre.1998.1676 · Cited by 526
Imaging of the elastic properties of tissue—A review
Gao, L., Parker, K. J., Lerner, R. M., & Levinson, S. F. (1996) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(96)00120-2 · Cited by 514
Imaging the elastic properties of tissue: the 20 year perspective
Parker, K. J., Doyley, M. M., & Rubens, D. J. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/1/r01 · Cited by 477
Moore, C. C., Lugo-Olivieri, C. H., McVeigh, E. R., & Zerhouni, E. A. (2000) · Radiology · doi:10.1148/radiology.214.2.r00fe17453 · Cited by 421
Three-dimensional left ventricular deformation in hypertrophic cardiomyopathy.
Young, A. A., Kramer, C. M., Ferrari, V. A., Axel, L., & Reichek, N. (1994) · Circulation · doi:10.1161/01.cir.90.2.854 · Cited by 401
Self-citationMcInerney, T., & Terzopoulos, D. (1995) · Computerized Medical Imaging and Graphics · doi:10.1016/0895-6111(94)00040-9 · Cited by 358
Deformable models in medical image analysis
McInerney, T., & Terzopoulos, D. (1996) · Proceedings of the Workshop on Mathematical Methods in Biomedical Image Analysis · doi:10.1109/mmbia.1996.534069 · Cited by 329
Biophysical Bases of Elasticity Imaging
Sarvazyan, A. P., Skovoroda, A. R., Emelianov, S. Y., Fowlkes, J. B., Pipe, J. G., Adler, R. S., Buxton, R. B., & Carson, P. L. (1995) · Acoustical Imaging · doi:10.1007/978-1-4615-1943-0_23 · Cited by 301
Ibrahim, E.-S. H. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-36 · Cited by 274
Garot, J., Bluemke, D. A., Osman, N. F., Rochitte, C. E., McVeigh, E. R., Zerhouni, E. A., Prince, J. L., & Lima, J. A. C. (2000) · Circulation · doi:10.1161/01.cir.101.9.981 · Cited by 246
Cardiovascular magnetic resonance physics for clinicians: part II
Biglands, J. D., Radjenovic, A., & Ridgway, J. P. (2012) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-14-66 · Cited by 241
“The addition of more rf pulses and modulating gradients makes the line pattern sharper [38].”
Chabiniok, R., Wang, V. Y., Hadjicharalambous, M., Asner, L., Lee, J., Sermesant, M., Kuhl, E., Young, A. A., Moireau, P., Nash, M. P., et al. (2016) · Interface Focus · doi:10.1098/rsfs.2015.0083 · Cited by 234
Cardiac rotation and relaxation in patients with aortic valve stenosis
Nagel, E. (2000) · European Heart Journal · doi:10.1053/euhj.1999.1736 · Cited by 224
“Improvements in the initial technique([12]) were achieved by using variable flip angles for image acquisition and by subtracting two measurements with complementary tagging signs (Complementary SPAtial Modulation of Magnetization=CSPAMM)([18,19]) in combination with the use of a breath-holding scheme for reduction of…”
BackgroundMethodPalmon, L. C., Reichek, N., Yeon, S. B., Clark, N. R., Brownson, D., Hoffman, E., & Axel, L. (1994) · Circulation · doi:10.1161/01.cir.89.1.122 · Cited by 213
Self-citationYoung, A. A., Imai, H., Chang, C. N., & Axel, L. (1994) · Circulation · doi:10.1161/01.cir.89.2.740 · Cited by 192
Self-citationGötte, M. J. W., van Rossum, A. C., Twisk, J. W. R., Kuijer, J. P. A., Marcus, J. T., & Visser, C. A. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)01186-4 · Cited by 182
“compute the deformation of each triangle (16,17).”
BackgroundMethodMotion in Cardiovascular MR Imaging
Scott, A. D., Keegan, J., & Firmin, D. N. (2009) · Radiology · doi:10.1148/radiol.2502071998 · Cited by 175
Analysis of 3-D Myocardial Motion in Tagged MR Images Using Nonrigid Image Registration
Chandrashekara, R., Mohiaddin, R. H., & Rueckert, D. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.834607 · Cited by 172
“Tagged magnetic resonance imaging (MRI) [2], [3] is a well known technique which can be used to obtain regional information about the deformation of the left ventricle (LV), and thus potentially help to diagnose CVDs.”
BackgroundKuijpers, D., Ho, K. Y. J. A. M., van Dijkman, P. R. M., Vliegenthart, R., & Oudkerk, M. (2003) · Circulation · doi:10.1161/01.cir.0000060544.41744.7c · Cited by 164
“Criteria for ending the dobutamine-CMR examinations were (1) development of new WMA (NWMA), (2) fall of systolic blood pressure of 40 mm Hg, (3) marked hypertension 240/ 120 mm Hg, (4) severe chest pain, (5) ventricular arrhythmias, and (6) intolerable side effects of dobutamine.”
MethodFogel, M. A., Weinberg, P. M., Fellows, K. E., & Hoffman, E. A. (1995) · Circulation · doi:10.1161/01.cir.92.2.219 · Cited by 159
Image-Based Predictive Modeling of Heart Mechanics
Wang, V. Y., Nielsen, P. M. F., & Nash, M. P. (2015) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071114-040609 · Cited by 63
Small animal cardiovascular MR imaging and spectroscopy
Bakermans, A. J., Abdurrachim, D., Moonen, R. P. M., Motaal, A. G., Prompers, J. J., Strijkers, G. J., Vandoorne, K., & Nicolay, K. (2015) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2015.03.001 · Cited by 35
Cardiac Magnetic Resonance Imaging for the Evaluation of Ventricular Function
Sarwar, A., Shapiro, M. D., Abbara, S., & Cury, R. C. (2008) · Seminars in Roentgenology · doi:10.1053/j.ro.2008.02.004 · Cited by 26
Metadata
- Authors
- Axel, L., & Dougherty, L.
- Venue
- Radiology
- Published
- 1989-08
- Volume
- 172
- Issue
- 2
- Pages
- 349-350
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2016395697
- Cited by
- 597
- References
- 0
- FWCI
- 8.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.