The DOI matches its Crossref record.
Ultrasmall superparamagnetic iron oxide: an intravenous contrast agent for assessing lymph nodes with MR imaging.
Abstract
An ultrasmall superparamagnetic iron oxide (USPIO) preparation was evaluated as a potential intravenous contrast agent for lymph nodes. Relaxation time measurements and magnetic resonance (MR) imaging were performed in rats with normal lymph nodes and in rats with lymph node metastases. In normal animals, lymph node relaxation times decreased maximally within 24-48 hours after intravenous administration of USPIO. Twenty-four hours after administration, the T2 of normal lymph nodes had decreased from 74 msec +/- 2.2 to 30 msec +/- 0.7 (USPIO, 40 mumol of iron per kilogram) or 15 msec +/- 0.0 (200 mumol Fe/kg), whereas the T2 of metastatic nodes did not change. MR imaging of the animal model of nodal metastases confirmed the hypothesis that intravenously administered USPIO decreases signal intensity of normal but not metastatic nodes. A single intravenous administration of USPIO may allow detection of nodal metastases on the basis of signal intensity characteristics rather than the currently used, insensitive size characteristics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Noninvasive detection of clinically occult lymph-node metastases in prostate cancer
Harisinghani, M. G., Barentsz, J., Hahn, P. F., Deserno, W. M., Tabatabaei, S., van de Kaa, C. H., de la Rosette, J., & Weissleder, R. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022749 · Cited by 1,971
Self-citationIron oxide MR contrast agents for molecular and cellular imaging
Bulte, J. W. M., & Kraitchman, D. L. (2004) · NMR in Biomedicine · doi:10.1002/nbm.924 · Cited by 1,500
Multifunctional magnetic nanoparticles for targeted imaging and therapy
MCCARTHY, J., & WEISSLEDER, R. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.014 · Cited by 892
Self-citationde Vries, I. J. M., Lesterhuis, W. J., Barentsz, J. O., Verdijk, P., van Krieken, J. H., Boerman, O. C., Oyen, W. J. G., Bonenkamp, J. J., Boezeman, J. B., Adema, G. J., et al. (2005) · Nature Biotechnology · doi:10.1038/nbt1154 · Cited by 821
Imaging macrophages with nanoparticles
Weissleder, R., Nahrendorf, M., & Pittet, M. J. (2014) · Nature Materials · doi:10.1038/nmat3780 · Cited by 809
Metadata
- Authors
- Weissleder, R., Elizondo, G., Wittenberg, J., Lee, A. S., Josephson, L., & Brady, T. J.
- Venue
- Radiology
- Published
- 1990-05
- Volume
- 175
- Issue
- 2
- Pages
- 494-498
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W1979234968
- Cited by
- 492
- References
- 0
- FWCI
- 6.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrasmall superparamagnetic iron oxide: an intravenous contrast agent for assessing lymph nodes with MR imaging. https://app.cochat.ai/papers/10.1148/radiology.175.2.2326475
- The paper
- Weissleder, R., Elizondo, G., Wittenberg, J., Lee, A. S., Josephson, L., & Brady, T. J. (1990). Ultrasmall superparamagnetic iron oxide: an intravenous contrast agent for assessing lymph nodes with MR imaging. Radiology. https://doi.org/10.1148/radiology.175.2.2326475
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.