Abdominal diffusion mapping with use of a whole-body echo-planar system.
The DOI matches its Crossref record.
Abstract
PURPOSE: To measure apparent diffusion coefficients (ADCs) of water in liver, spleen, kidney, and muscle. MATERIALS AND METHODS: Ten volunteers (seven women and three men, aged 19-31 years [mean, 24 years]) and nine patients (five women and four men, aged 49-70 years [mean, 62 years]) (liver cyst, n = 3; liver hemangioma, n = 3; liver cirrhosis, n = 2; hepatocellular carcinoma, n = 1; and liver metastasis, n = 1) underwent magnetic resonance (MR) imaging. A stimulated-echo acquisition mode (STEAM)-type excitation and echo-planar imaging (EPI) readout was used in a 1.5-T echo-planar MR imaging system. RESULTS: ADCs measured in volunteers were liver, 1.39 x 10(-3) mm2/sec +/- 0.16; spleen, 0.95 x 10(-3) mm2/sec +/- 0.15; muscle, 1.99 x 10(-3) mm2/sec +/- 0.16; and kidney, 3.54 x 10(-3) mm2/sec +/- 0.47 (mean +/- standard deviation). Distinctive ADC values were found in organs with abnormalities. ADCs in patients with hepatic disease included liver cysts, 3.9-5.3; liver hemangiomas, 2.0-2.8; liver metastases from an islet cell tumor, 1.2; hepatocellular carcinoma, 1.7; and liver cirrhosis, 0.9-1.2 x 10(-3) mm2/sec. CONCLUSION: In vivo diffusion measurements of abdominal organs obtained with MR imaging may prove helpful in the identification and classification of abdominal disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Diffusion-weighted MR Imaging of the Liver
Taouli, B., & Koh, D.-M. (2010) · Radiology · doi:10.1148/radiol.09090021 · Cited by 810
Differentiation of clinically benign and malignant breast lesions using diffusion‐weighted imaging
Guo, Y., Cai, Y., Cai, Z., Gao, Y., An, N., Ma, L., Mahankali, S., & Gao, J. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10140 · Cited by 714
Taouli, B., Vilgrain, V., Dumont, E., Daire, J.-L., Fan, B., & Menu, Y. (2003) · Radiology · doi:10.1148/radiol.2261011904 · Cited by 577
Parikh, T., Drew, S. J., Lee, V. S., Wong, S., Hecht, E. M., Babb, J. S., & Taouli, B. (2008) · Radiology · doi:10.1148/radiol.2463070432 · Cited by 560
Yamada, I., Aung, W., Himeno, Y., Nakagawa, T., & Shibuya, H. (1999) · Radiology · doi:10.1148/radiology.210.3.r99fe17617 · Cited by 519
Kwee, T. C., Takahara, T., Ochiai, R., Nievelstein, R. A. J., & Luijten, P. R. (2008) · European Radiology · doi:10.1007/s00330-008-0968-z · Cited by 410
Takeuchi, M., Sasaki, S., Ito, M., Okada, S., Takahashi, S., Kawai, T., Suzuki, K., Oshima, H., Hara, M., & Shibamoto, Y. (2009) · Radiology · doi:10.1148/radiol.2511080873 · Cited by 372
Ichikawa, T., Haradome, H., Hachiya, J., Nitatori, T., & Araki, T. (1998) · American Journal of Roentgenology · doi:10.2214/ajr.170.2.9456953 · Cited by 314
Extracranial applications of diffusion-weighted magnetic resonance imaging
Thoeny, H. C., & De Keyzer, F. (2007) · European Radiology · doi:10.1007/s00330-006-0547-0 · Cited by 269
Diffusion-weighted magnetic resonance imaging for the assessment of fibrosis in chronic hepatitis C
Lewin, M., Poujol-Robert, A., Boëlle, P.-Y., Wendum, D., Lasnier, E., Viallon, M., Guéchot, J., Hoeffel, C., Arrivé, L., Tubiana, J.-M., et al. (2007) · Hepatology · doi:10.1002/hep.21747 · Cited by 265
Gudbjartsson, H., Maier, S. E., Mulkern, R. V., Mórocz, I. Á., Patz, S., & Jolesz, F. A. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360403 · Cited by 227
Abdomen: Diffusion-weighted MR Imaging with Pulse-triggered Single-Shot Sequences
Mürtz, P., Flacke, S., Träber, F., van den Brink, J. S., Gieseke, J., & Schild, H. H. (2002) · Radiology · doi:10.1148/radiol.2241011117 · Cited by 222
Koinuma, M., Ohashi, I., Hanafusa, K., & Shibuya, H. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20344 · Cited by 218
Buisson, A., Joubert, A., Montoriol, P. ‐., Ines, D. D., Hordonneau, C., Pereira, B., Garcier, J. ‐., Bommelaer, G., & Petitcolin, V. (2013) · Alimentary Pharmacology & Therapeutics · doi:10.1111/apt.12201 · Cited by 199
Kandpal, H., Sharma, R., Madhusudhan, K. S., & Kapoor, K. S. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.08.1260 · Cited by 198
“© American Roentgen Ray Society D iffusion-weighted MRI (DWI) of the abdomen has seen significant improvements since the earliest reports more than two decades ago [1].”
BackgroundNonalcoholic fatty liver disease
Erickson, S. K. (2009) · Journal of Lipid Research · doi:10.1194/jlr.r800089-jlr200 · Cited by 194
Mori, T., Nomori, H., Ikeda, K., Kawanaka, K., Shiraishi, S., Katahira, K., & Yamashita, Y. (2008) · Journal of Thoracic Oncology · doi:10.1097/jto.0b013e318168d9ed · Cited by 188
Utility of diffusion‐weighted MRI in distinguishing benign and malignant hepatic lesions
Miller, F. H., Hammond, N., Siddiqi, A. J., Shroff, S., Khatri, G., Wang, Y., Merrick, L. B., & Nikolaidis, P. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22235 · Cited by 188
“Other investigators have shown that ADC values for metastases can be lower (3,8) or higher (11,31) compared to the ADC values for HCC, without any statistical difference.”
BackgroundMethodResultInfluentialKiryu, S., Dodanuki, K., Takao, H., Watanabe, M., Inoue, Y., Takazoe, M., Sahara, R., Unuma, K., & Ohtomo, K. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21725 · Cited by 185
Mannelli, L., Kim, S., Hajdu, C. H., Babb, J. S., Clark, T. W. I., & Taouli, B. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.08.1461 · Cited by 182
“DWI of the liver has been used mostly for detection and characterization of liver lesions [34–43].”
MethodZhang, J. L., Sigmund, E. E., Chandarana, H., Rusinek, H., Chen, Q., Vivier, P.-H., Taouli, B., & Lee, V. S. (2010) · Radiology · doi:10.1148/radiol.09090891 · Cited by 179
Ichikawa, T., Haradome, H., Hachiya, J., Nitatori, T., & Araki, T. (1999) · Abdominal Imaging · doi:10.1007/s002619900539 · Cited by 173
“[11] reported that Correspondence to: T.”
BackgroundTaouli, B., Sandberg, A., Stemmer, A., Parikh, T., Wong, S., Xu, J., & Lee, V. S. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21876 · Cited by 167
Muhi, A., Ichikawa, T., Motosugi, U., Sano, K., Matsuda, M., Kitamura, T., Nakazawa, T., & Araki, T. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21931 · Cited by 164
Katayama, M., Masui, T., Kobayashi, S., Ito, T., Sakahara, H., Nozaki, A., & Kabasawa, H. (2002) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200203000-00015 · Cited by 103
Invited. Ultrafast MR imaging of the abdomen: Echo planar imaging and diffusion‐weighted imaging
Yamashita, Y., Tang, Y., & Takahashi, M. (1998) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880080216 · Cited by 92
Metadata
- Authors
- Müller, M. F., Prasad, P., Siewert, B., Nissenbaum, M. A., Raptopoulos, V, & Edelman, R. R.
- Venue
- Radiology
- Published
- 1994-02
- Volume
- 190
- Issue
- 2
- Pages
- 475-478
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2086872333
- Cited by
- 245
- References
- 0
- FWCI
- 4.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.