Lung cancer: reproducibility of quantitative measurements for evaluating 2-[F-18]-fluoro-2-deoxy-D-glucose uptake at PET.
The DOI matches its Crossref record.
Abstract
PURPOSE: To study the precision of repeated 2-[fluorine-18]-fluoro-2-deoxy-D-glucose (FDG) uptake measurements at positron emission tomography (PET) in patients with primary lung cancer. MATERIALS AND METHODS: Ten patients with untreated lung cancer underwent two dynamic FDG PET examinations after a 4-hour fast within 1 week. Kinetic modeling of tumor FDG uptake was performed on the basis of a three-compartment model. The tumor concentration of F-18 (standardized uptake value calculated on the basis of predicted lean body mass [SUV-lean]) was also measured 50-60 minutes after injection of a tracer. Blood glucose, insulin, and free fatty acid levels were monitored. RESULTS: SUV-lean and the FDG influx constant Ki were measured with a mean +/- standard deviation difference of 10% +/- 7 and 10% +/- 8, respectively, over repeated PET scans. The mean difference was reduced to 6% +/- 6 and 6% +/- 5 by multiplying SUV-lean and Ki by plasma glucose concentration. CONCLUSION: SUV-lean and graphical Ki can be measured reproducibly, supporting their use in quantitative FDG PET algorithms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
From RECIST to PERCIST: Evolving Considerations for PET Response Criteria in Solid Tumors
Wahl, R. L., Jacene, H., Kasamon, Y., & Lodge, M. A. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.057307 · Cited by 3,777
“(113) used a smaller maximal pixel volume, but it was still about 19 times larger than the volume of a single voxel used in many current scanners.”
BackgroundMethodInfluentialSelf-citationYoung, H., Baum, R., Cremerius, U., Herholz, K., Hoekstra, O., Lammertsma, A. A., Pruim, J., & Price, P. (1999) · European Journal of Cancer · doi:10.1016/s0959-8049(99)00229-4 · Cited by 1,720
Martinez-Möller, A., Souvatzoglou, M., Delso, G., Bundschuh, R. A., Chefd'hotel, C., Ziegler, S. I., Navab, N., Schwaiger, M., & Nekolla, S. G. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.054726 · Cited by 712
Progress and Promise of FDG-PET Imaging for Cancer Patient Management and Oncologic Drug Development
Kelloff, G. J., Hoffman, J. M., Johnson, B., Scher, H. I., Siegel, B. A., Cheng, E. Y., Cheson, B. D., O'Shaughnessy, J., Guyton, K. Z., Mankoff, D. A., et al. (2005) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-04-2626 · Cited by 671
(2004) · PubMed · Cited by 653
Kinahan, P. E., & Fletcher, J. W. (2010) · Seminars in Ultrasound, CT and MRI · doi:10.1053/j.sult.2010.10.001 · Cited by 631
Oncological applications of positron emission tomography with fluorine-18 fluorodeoxyglucose
Rigo, P., Paulus, P., Kaschten, B. J., Hustinx, R., Bury, T., Jerusalem, G., Benoit, T., & Foidart-Willems, J. (1996) · European Journal of Nuclear Medicine · doi:10.1007/bf01249629 · Cited by 501
Weber, W. A., Petersen, V., Schmidt, B., Tyndale-Hines, L., Link, T., Peschel, C., & Schwaiger, M. (2003) · Journal of Clinical Oncology · doi:10.1200/jco.2003.12.004 · Cited by 493
Metrology Standards for Quantitative Imaging Biomarkers
Sullivan, D. C., Obuchowski, N. A., Kessler, L. G., Raunig, D. L., Gatsonis, C., Huang, E. P., Kondratovich, M., McShane, L. M., Reeves, A. P., Barboriak, D. P., et al. (2015) · Radiology · doi:10.1148/radiol.2015142202 · Cited by 435
Self-citationChen, W., Delaloye, S., Silverman, D. H. S., Geist, C., Czernin, J., Sayre, J., Satyamurthy, N., Pope, W., Lai, A., Phelps, M. E., et al. (2007) · Journal of Clinical Oncology · doi:10.1200/jco.2006.10.5825 · Cited by 393
Zhao, B., James, L. P., Moskowitz, C. S., Guo, P., Ginsberg, M. S., Lefkowitz, R. A., Qin, Y., Riely, G. J., Kris, M. G., & Schwartz, L. H. (2009) · Radiology · doi:10.1148/radiol.2522081593 · Cited by 339
Römer, W., Hanauske, A.-R., Ziegler, S. I., Thödtmann, R., Weber, W., Fuchs, C., Enne, W., Herz, M., Nerl, C., Garbrecht, M., et al. (1998) · PubMed · doi:10.1182/blood.v91.12.4464 · Cited by 335
Ott, K., Fink, U., Becker, K., Stahl, A., Dittler, H.-J., Busch, R., Stein, H., Lordick, F., Link, T., Schwaiger, M., et al. (2003) · Journal of Clinical Oncology · doi:10.1200/jco.2003.06.574 · Cited by 318
Positron Emission Tomography As an Imaging Biomarker
Weber, W. A. (2006) · Journal of Clinical Oncology · doi:10.1200/jco.2006.06.6068 · Cited by 312
Chen, K. Y., Cypess, A. M., Laughlin, M. R., Haft, C. R., Hu, H. H., Bredella, M. A., Enerbäck, S., Kinahan, P. E., Lichtenbelt, W. V. M., Lin, F. I., et al. (2016) · Cell Metabolism · doi:10.1016/j.cmet.2016.07.014 · Cited by 308
Self-citationWesterterp, M., van Westreenen, H. L., Reitsma, J. B., Hoekstra, O. S., Stoker, J., Fockens, P., Jager, P. L., Van Eck-Smit, B. L. F., Plukker, J. T. M., van Lanschot, J. J. B., et al. (2005) · Radiology · doi:10.1148/radiol.2363041042 · Cited by 299
Krak, N. C., Boellaard, R., Hoekstra, O. S., Twisk, J. W. R., Hoekstra, C. J., & Lammertsma, A. A. (2005) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-004-1566-1 · Cited by 283
Avril, N., Sassen, S., Schmalfeldt, B., Naehrig, J., Rutke, S., Weber, W. A., Werner, M., Graeff, H., Schwaiger, M., & Kuhn, W. (2005) · Journal of Clinical Oncology · doi:10.1200/jco.2005.06.965 · Cited by 283
Kenny, L., Coombes, R. C., Vigushin, D. M., Al-Nahhas, A., Shousha, S., & Aboagye, E. O. (2007) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-007-0379-4 · Cited by 275
Sugawara, Y., Zasadny, K. R., Neuhoff, A. W., & Wahl, R. L. (1999) · Radiology · doi:10.1148/radiology.213.2.r99nv37521 · Cited by 265
Self-citationNoise Considerations for PET Quantification Using Maximum and Peak Standardized Uptake Value
Lodge, M. A., Chaudhry, M. A., & Wahl, R. L. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.101733 · Cited by 226
Self-citationRepeatability of SUV in Oncologic 18F-FDG PET
Lodge, M. A. (2017) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.186353 · Cited by 214
Impact of the Definition of Peak Standardized Uptake Value on Quantification of Treatment Response
Vanderhoek, M., Perlman, S. B., & Jeraj, R. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.093443 · Cited by 188
Utech, C. I., Young, C. S., & Winter, P. F. (1996) · European Journal of Nuclear Medicine · doi:10.1007/bf01249621 · Cited by 165
“Since then PET has emerged as a noninvasive biochemical imaging technique to identify primary tumors and metastases [8-18].”
Quantitative assessment of tumor metabolism using FDG-PET imaging
Weber, W. A., Schwaiger, M., & Avril, N. (2000) · Nuclear Medicine and Biology · doi:10.1016/s0969-8051(00)00141-4 · Cited by 165
Repeatability of 18F-FDG Uptake Measurements in Tumors: A Metaanalysis
de Langen, A. J., Vincent, A., Velasquez, L. M., van Tinteren, H., Boellaard, R., Shankar, L. K., Boers, M., Smit, E. F., Stroobants, S., Weber, W. A., et al. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.095299 · Cited by 157
“(20) excluded lesions with a diameter lower than 2 cm, whereas the other studies had no clear restrictions regarding lesion size.”
BackgroundMethodInfluential(2005) · PubMed · Cited by 156
Eskian, M., Alavi, A., Khorasanizadeh, M., Viglianti, B. L., Jacobsson, H., Barwick, T. D., Meysamie, A., Yi, S. K., Iwano, S., Bybel, B., et al. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-018-4194-x · Cited by 109
Instrumentation factors affecting variance and bias of quantifying tracer uptake with PET/CT
Doot, R. K., Scheuermann, J. S., Christian, P. E., Karp, J. S., & Kinahan, P. E. (2010) · Medical Physics · doi:10.1118/1.3499298 · Cited by 82
Variance of SUVs for FDG-PET/CT is Greater in Clinical Practice Than Under Ideal Study Settings
Kumar, V., Nath, K., Berman, C. G., Kim, J., Tanvetyanon, T., Chiappori, A. A., Gatenby, R. A., Gillies, R. J., & Eikman, E. A. (2013) · Clinical Nuclear Medicine · doi:10.1097/rlu.0b013e318279ffdf · Cited by 76
Increasing Uptake Time in FDG-PET: Standardized Uptake Values in Normal Tissues at 1 versus 3 h
Chin, B. B., Green, E. D., Turkington, T. G., Hawk, T. C., & Coleman, R. E. (2009) · Molecular Imaging and Biology · doi:10.1007/s11307-008-0177-9 · Cited by 65
Sprinz, C., Zanon, M., Altmayer, S., Watte, G., Irion, K., Marchiori, E., & Hochhegger, B. (2018) · Scientific Reports · doi:10.1038/s41598-018-20529-4 · Cited by 59
Mittal, B., Kuruva, M., Abrar, M., Kashyap, R., & Bhattacharya, A. (2012) · Indian Journal of Nuclear Medicine · doi:10.4103/0972-3919.108835 · Cited by 24
Two-Time-Point FDG PET/CT: Liver SULmean Repeatability
Tahari, A. K., Paidpally, V., Chirindel, A., Wahl, R. L., & Subramaniam, R. M. (2015) · American Journal of Roentgenology · doi:10.2214/ajr.14.12719 · Cited by 10
Self-citation
Metadata
- Authors
- Minn, H., Zasadny, K. R., Quint, L. E., & Wahl, R. L.
- Venue
- Radiology
- Published
- 1995-07
- Volume
- 196
- Issue
- 1
- Pages
- 167-173
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2077694074
- Cited by
- 260
- References
- 0
- FWCI
- 6.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.