Normalizing fractional moving blood volume estimates with power Doppler US: defining a stable intravascular point with the cumulative power distribution function.
The DOI matches its Crossref record.
Abstract
PURPOSE: To normalize the power Doppler ultrasound (US) signal to the expected signal from 100% blood in the calculation of a fractional moving blood volume estimate. MATERIALS AND METHODS: To locate the signal from flowing blood with a consistent backscatter coefficient, the authors estimated the knee of the cumulative Doppler power distribution function. They used a flow-tube phantom to test the use of this knee to locate a radial position that would fall into a region of high shear stress and minimal rouleaux formation. They also studied how well the method normalized fractional moving blood volume estimates of the right renal cortex in a volunteer when simulating different body habitus and in a group of six healthy volunteers to estimate variability. RESULTS: Over five flow velocities and over undersaturated to severely oversaturated receiver gains, the calculated flow-tube area was a mean 89% +/- 7 (+/- standard deviation) of a standard. In humans, the technique normalized the fractional moving blood volume estimates over an 8-dB receiver gain variation; the mean +/- standard deviation of fractional moving blood volume estimates for the six volunteers was 37.6% +/- 3.6. CONCLUSION: Vascularity estimates with power Doppler US are feasible with a normalization scheme based on the cumulative Doppler power distribution function.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Walther, M., Harms, H., Krenn, V., Radke, S., Faehndrich, T.-P., & Gohlke, F. (2001) · Arthritis & Rheumatism · doi:10.1002/1529-0131(200102)44:2<331::aid-anr50>3.0.co;2-0 · Cited by 447
Functional ultrasound imaging of the brain: theory and basic principles
Mace, E., Montaldo, G., Osmanski, B.-F., Cohen, I., Fink, M., & Tanter, M. (2013) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2013.2592 · Cited by 327
Evaluation of tumor angiogenesis with US: Imaging, Doppler, and contrast agents
Ferrara, K. W., Merritt, C. R. B., Burns, P. N., Stuart Foster, F., Mattrey, R. F., & Wickline, S. A. (2000) · Academic Radiology · doi:10.1016/s1076-6332(00)80631-5 · Cited by 186
Hernandez‐Andrade, E., Jansson, T., Ley, D., Bellander, M., Persson, M., Lingman, G., & Maršál, K. (2004) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.1002 · Cited by 58
Quantification of power Doppler and the index 'fractional moving blood volume' (FMBV)
Welsh, A. (2004) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.1037 · Cited by 44
Stevenson, G. N., Collins, S. L., Welsh, A. W., Impey, L. W., & Noble, J. A. (2015) · Radiology · doi:10.1148/radiol.14132363 · Cited by 38
Three-dimensional US Fractional Moving Blood Volume: Validation of Renal Perfusion Quantification
Welsh, A. W., Fowlkes, J. B., Pinter, S. Z., Ives, K. A., Owens, G. E., Rubin, J. M., Kripfgans, O. D., Looney, P., Collins, S. L., & Stevenson, G. N. (2019) · Radiology · doi:10.1148/radiol.2019190248 · Cited by 31
Self-citationCollins, S. L., Welsh, A. W., Impey, L., Noble, J. A., & Stevenson, G. N. (2017) · PLOS ONE · doi:10.1371/journal.pone.0178675 · Cited by 25
Welsh, A. W., Collins, S. L., Stevenson, G. N., Noble, J. A., & Impey, L. (2012) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.11139 · Cited by 15
Yin, Y., Looney, P., & Collins, S. L. (2020) · Medical Imaging 2020: Computer-Aided Diagnosis · doi:10.1117/12.2549349 · Cited by 4
Metadata
- Authors
- Rubin, J. M., Bude, R. O., Fowlkes, J. B., Spratt, R. S., Carson, P. L., & Adler, R. S.
- Venue
- Radiology
- Published
- 1997-12
- Volume
- 205
- Issue
- 3
- Pages
- 757-765
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W1975611796
- Cited by
- 107
- References
- 0
- FWCI
- 4.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.