Metastases from Non-Small Cell Lung Cancer: Mediastinal Staging in the 1990s—Meta-analytic Comparison Of PET and CT
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
PURPOSE: To meta-analytically compare 2-[fluorine 18]fluoro-2-deoxy-D-glucose positron emission tomography (PET) and computed tomography (CT) for the demonstration of mediastinal nodal metastases in patients with non-small cell lung cancer. MATERIALS AND METHODS: English-language reports on the diagnostic performance of PET (14 studies, 514 patients) and/or CT (29 studies, 2,226 patients) for demonstration of mediastinal nodal metastases from NSCLC were selected by using the MEDLINE database. In eligible studies, an objective diagnostic standard was used, data were presented to allow recalculation of contingency tables, and established diagnostic criteria were used for abnormal test results. Summary receiver operating characteristic (ROC) curves were calculated. RESULTS: Pooled point estimates of diagnostic performance and summary ROC curves indicated that PET was significantly more accurate than CT for demonstration of nodal metastases (P < .001). Mean sensitivity and specificity (+/- 95% CI) were 0.79 +/- 0.03 and 0.91 +/- 0.02, respectively, for PET and 0.60 +/- 0.02 and 0.77 +/- 0.02, respectively, for CT. The log odds ratios were 1.79 (95% CI: 1.49, 2.09) for CT and 3.77 (95% CI: 2.77, 4.77) for PET (P < .001). Subgroup analyses did not alter findings. CONCLUSION: PET is superior to CT for mediastinal staging of non-small cell lung cancer, independent of performance index or clinical context of PET imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Operating characteristics of a rank correlation test for publication bias
Begg, C. B., & Mazumdar, M. (1994) · Biometrics · doi:10.2307/2533446 · Cited by 16,955
Landis, S. H., Murray, T., Bolden, S., & Wingo, P. A. (1998) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.48.1.6 · Cited by 2,341
Moses, L. E., Shapiro, D., & Littenberg, B. (1993) · Statistics in Medicine · doi:10.1002/sim.4780121403 · Cited by 1,405
Use of methodological standards in diagnostic test research. Getting better but still not good
Reid, M. C. (1995) · JAMA · doi:10.1001/jama.274.8.645 · Cited by 712
McLoud, T. C., Bourgouin, P. M., Greenberg, R. W., Kosiuk, J. P., Templeton, P. A., Shepard, J. A., Moore, E. H., Wain, J. C., Mathisen, D. J., & Grillo, H. C. (1992) · Radiology · doi:10.1148/radiology.182.2.1732943 · Cited by 560
Oncological applications of positron emission tomography with fluorine-18 fluorodeoxyglucose
Rigo, P., Paulus, P., Kaschten, B. J., Hustinx, R., Bury, T., Jerusalem, G., Benoit, T., & Foidart-Willems, J. (1996) · European Journal of Nuclear Medicine · doi:10.1007/bf01249629 · Cited by 501
Meta-analysis: State-of-the-Science
Dickersin, K., & Berlin, J. A. (1992) · Epidemiologic Reviews · doi:10.1093/oxfordjournals.epirev.a036084 · Cited by 498
Biases in the assessment of diagnostic tests
Begg, C. B. (1987) · Statistics in Medicine · doi:10.1002/sim.4780060402 · Cited by 496
Meta-analytic methods for diagnostic test accuracy
Irwig, L., Macaskill, P., Glasziou, P., & Fahey, M. (1995) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(94)00099-c · Cited by 467
Publication Bias and Dissemination of Clinical Research
Begg, C. B., & Berlin, J. A. (1989) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/81.2.107 · Cited by 440
Cited by
Methods for Staging Non-small Cell Lung Cancer
Silvestri, G. A., Gonzalez, A. V., Jantz, M. A., Margolis, M. L., Gould, M. K., Tanoue, L. T., Harris, L. J., & Detterbeck, F. C. (2013) · Chest · doi:10.1378/chest.12-2355 · Cited by 1,483
Lardinois, D., Weder, W., Hany, T. F., Kamel, E. M., Korom, S., Seifert, B., von Schulthess, G. K., & Steinert, H. C. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022136 · Cited by 1,416
Pfister, D. G., Johnson, D. H., Azzoli, C. G., Sause, W., Smith, T. J., Baker Jr, S., Olak, J., Stover, D., Strawn, J. R., Turrisi, A. T., et al. (2004) · Journal of Clinical Oncology · doi:10.1200/jco.2004.09.053 · Cited by 1,413
Recommendations on the Use of 18F-FDG PET in Oncology
Fletcher, J. W., Djulbegovic, B., Soares, H. P., Siegel, B. A., Lowe, V. J., Lyman, G. H., Coleman, R. E., Wahl, R., Paschold, J. C., Avril, N., et al. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.047787 · Cited by 1,101
Self-citationGould, M. K., Maclean, C. C., Kuschner, W. G., Rydzak, C. E., & Owens, D. K. (2001) · JAMA · doi:10.1001/jama.285.7.914 · Cited by 1,094
Gold nanoparticles as novel agents for cancer therapy
Jain, S., Hirst, D. G., & O'Sullivan, J. M. (2012) · The British Journal of Radiology · doi:10.1259/bjr/59448833 · Cited by 1,059
van Tinteren, H., Hoekstra, O. S., Smit, E. F., van den Bergh, J. H., Schreurs, A. J., Stallaert, R. A., van Velthoven, P. C., Comans, E. F., Diepenhorst, F. W., Verboom, P., et al. (2002) · The Lancet · doi:10.1016/s0140-6736(02)08352-6 · Cited by 851
Noninvasive Staging of Non-small Cell Lung Cancer*
Toloza, E. M., Harpole, L., & McCrory, D. C. (2003) · Chest · doi:10.1378/chest.123.1_suppl.137s · Cited by 745
Gould, M. K., Kuschner, W. G., Rydzak, C. E., Maclean, C. C., Demas, A. N., Shigemitsu, H., Chan, J. K., & Owens, D. K. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-139-11-200311180-00013 · Cited by 687
Noninvasive Staging of Non-small Cell Lung Cancer
Silvestri, G. A., Gould, M. K., Margolis, M. L., Tanoue, L. T., McCrory, D., Toloza, E., & Detterbeck, F. (2007) · Chest · doi:10.1378/chest.07-1360 · Cited by 622
Gu, P., Zhao, Y.-Z., Jiang, L.-Y., Zhang, W., Xin, Y., & Han, B.-H. (2009) · European Journal of Cancer · doi:10.1016/j.ejca.2008.11.043 · Cited by 620
(2005) · PubMed · Cited by 612
Ciernik, I. F., Dizendorf, E., Baumert, B. G., Reiner, B., Burger, C., Davis, J. B., Lütolf, U. M., Steinert, H. C., & Von Schulthess, G. K. (2003) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(03)00346-8 · Cited by 543
Non–Small Cell Lung Cancer: Dual-Modality PET/CT in Preoperative Staging
Antoch, G., Stattaus, J., Nemat, A. T., Marnitz, S., Beyer, T., Kuehl, H., Bockisch, A., Debatin, J. F., & Freudenberg, L. S. (2003) · Radiology · doi:10.1148/radiol.2292021598 · Cited by 540
Shim, S. S., Lee, K. S., Kim, B.-T., Chung, M. J., Lee, E. J., Han, J., Choi, J. Y., Kwon, O. J., Shim, Y. M., & Kim, S. (2005) · Radiology · doi:10.1148/radiol.2363041310 · Cited by 444
Use of PET and PET/CT for Radiation Therapy Planning: IAEA expert report 2006–2007
MacManus, M., Nestle, U., Rosenzweig, K. E., Carrio, I., Messa, C., Belohlavek, O., Danna, M., Inoue, T., Deniaud-Alexandre, E., Schipani, S., et al. (2009) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2008.11.008 · Cited by 367
Reske, S. N., & Kotzerke, J. (2001) · European Journal of Nuclear Medicine · doi:10.1007/s002590100626 · Cited by 365
Positron Emission Tomography Scanning: Current and Future Applications
Czernin, J., & Phelps, M. E. (2002) · Annual Review of Medicine · doi:10.1146/annurev.med.53.082901.104028 · Cited by 328
Mah, K., Caldwell, C. B., Ung, Y. C., Danjoux, C. E., Balogh, J. M., Ganguli, S. N., Ehrlich, L. E., & Tirona, R. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(01)01824-7 · Cited by 307
Reed, C. E., Harpole, D. H., Posther, K. E., Woolson, S. L., Downey, R. J., Meyers, B. F., Heelan, R. T., MacApinlac, H. A., Jung, S.-H., Silvestri, G. A., et al. (2003) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2003.07.030 · Cited by 300
Mac Manus, M. P., Hicks, R. J., Matthews, J. P., Hogg, A., McKenzie, A. F., Wirth, A., Ware, R. E., & Ball, D. L. (2001) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(01)01477-8 · Cited by 297
Birim, Ö., Kappetein, A. P., Stijnen, T., & Bogers, A. J. J. C. (2005) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2004.06.041 · Cited by 284
Clinical role of positron emission tomography in oncology
Bomanji, J., Costa, D., & Ell, P. (2001) · The Lancet Oncology · doi:10.1016/s1470-2045(00)00257-6 · Cited by 281
Defining a radiotherapy target with positron emission tomography
Black, Q. C., Grills, I. S., Kestin, L. L., Wong, C.-Y. O., Wong, J. W., Martinez, A. A., & Yan, D. (2004) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.06.254 · Cited by 263
Im, H.-J., Pak, K., Cheon, G. J., Kang, K. W., Kim, S.-J., Kim, I.-J., Chung, J.-K., Kim, E. E., & Lee, D. S. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-014-2903-7 · Cited by 248
“[41] 1999 USA 14 514 Staging Detection of mediastinal lymph node metastasis Sensitivity/ specificity”
BackgroundRecent Advances in the Diagnosis and Management of Malignant Pleural Effusions
Heffner, J. E., & Klein, J. S. (2008) · Mayo Clinic Proceedings · doi:10.1016/s0025-6196(11)60848-3 · Cited by 231
Mujoomdar, A., Austin, J. H. M., Malhotra, R., Powell, C. A., Pearson, G. D. N., Shiau, M. C., & Raftopoulos, H. (2007) · Radiology · doi:10.1148/radiol.2423051707 · Cited by 228
Nestle, U., Kremp, S., & Grosu, A.-L. (2006) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2006.09.011 · Cited by 214
“There is a large body of literature on the diagnostic performance of FDG-PET in the lymph node staging of NSCLC (see above) [8,31,47,91].”
Background(2004) · PubMed · Cited by 211
Isasi, C. R., Lu, P., & Blaufox, M. D. (2005) · Cancer · doi:10.1002/cncr.21253 · Cited by 208
“, 1998 ECAT 953/15 Yes Visual Pathology and clinical follow-up 43 [18–67]”
BackgroundMethodInfluential18F-FDG PET for Mediastinal Staging of Lung Cancer: Which SUV Threshold Makes Sense?
Hellwig, D., Graeter, T. P., Ukena, D., Groeschel, A., Sybrecht, G. W., Schaefers, H.-J., & Kirsch, C.-M. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.044362 · Cited by 200
“The data presented here agree with mediastinal-staging meta-analyses showing sensitivities of 87%–90% and specificities of about 85% for 18F-FDG PET (13,16).”
ResultWhole-body FDG-PET imaging in the management of patients with cancer
Hustinx, R., Bénard, F., & Alavi, A. (2002) · Seminars in Nuclear Medicine · doi:10.1053/snuc.2002.29272 · Cited by 199
Computed Tomography: Revolutionizing the Practice of Medicine for 40 Years
Rubin, G. D. (2014) · Radiology · doi:10.1148/radiol.14141356 · Cited by 197
PET/CT imaging in different types of lung cancer: An overview
Ambrosini, V., Nicolini, S., Caroli, P., Nanni, C., Massaro, A., Marzola, M. C., Rubello, D., & Fanti, S. (2012) · European Journal of Radiology · doi:10.1016/j.ejrad.2011.03.020 · Cited by 190
Billé, A., Pelosi, E., Skanjeti, A., Arena, V., Errico, L., Borasio, P., Mancini, M., & Ardissone, F. (2009) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2009.04.003 · Cited by 186
A meta-analysis of FDG-PET for the evaluation of breast cancer recurrence and metastases
Isasi, C. R., Moadel, R. M., & Blaufox, M. D. (2005) · Breast Cancer Research and Treatment · doi:10.1007/s10549-004-3291-7 · Cited by 181
Yi, C. A., Shin, K. M., Lee, K. S., Kim, B.-T., Kim, H., Kwon, O. J., Choi, J. Y., & Chung, M. J. (2008) · Radiology · doi:10.1148/radiol.2482071822 · Cited by 177
Workman, R. B., & Coleman, R. E. (2006) · PET/CT · doi:10.1007/978-0-387-38335-4_3 · Cited by 176
“A meta-analysis conducted in 1999 of 14 FDG-PET studies and 29 CT studies demonstrated an overall diagnostic accuracy of 92% for FDG-PET and 75% for CT in staging the mediastinum [22].”
MethodCost-Effectiveness of Alternative Management Strategies for Patients with Solitary Pulmonary Nodules
Gould, M. K., Sanders, G. D., Barnett, P. G., Rydzak, C. E., Maclean, C. C., McClellan, M. B., & Owens, D. K. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-9-200305060-00009 · Cited by 172
“Use of FDG-PET is more accurate than CT for detecting regional lymph node metastases (82, 83), which occur in approximately 12% of patients with T1 lung cancer (12–19), and may also detect occult distant metastases (82).”
BackgroundYap, C. S., Czernin, J., Fishbein, M. C., Cameron, R. B., Schiepers, C., Phelps, M. E., & Weber, W. A. (2006) · Chest · doi:10.1378/chest.129.2.393 · Cited by 166
Vesselle, H., Salskov, A., Turcotte, E., Wiens, L., Schmidt, R., Jordan, C. D., Vallières, E., & Wood, D. E. (2008) · Journal of Thoracic Oncology · doi:10.1097/jto.0b013e31818307a7 · Cited by 165
Hicks, R. J., Mac Manus, M. P., Matthews, J. P., Hogg, A., Binns, D., Rischin, D., Ball, D. L., & Peters, L. J. (2004) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.03.036 · Cited by 164
Fischer, B. M., Mortensen, J., & Højgaard, L. (2001) · The Lancet Oncology · doi:10.1016/s1470-2045(01)00555-1 · Cited by 160
(2004) · PubMed · Cited by 141
Metadata
- Authors
- Dwamena, B. A., Sonnad, S. S., Angobaldo, J. O., & Wahl, R. L.
- Venue
- Radiology
- Published
- 1999-11
- Volume
- 213
- Issue
- 2
- Pages
- 530-536
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2069752504
- Cited by
- 649
- References
- 35
- FWCI
- 25.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.