Near-Infrared Optical Imaging of Protease Activity for Tumor Detection
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
PURPOSE: To build and test an optical imaging system that is sensitive to near-infrared fluorescent molecular probes activated by specific enzymes in tumor tissues in mice. MATERIALS AND METHODS: The imaging system consisted of a source that delivered 610-650-nm excitation light within a lighttight chamber, a 700-nm longpass filter for selecting near-infrared fluorescence emission photons from tissues, and a charge-coupled device (CCD) for recording images. The molecular probe was a biocompatible autoquenched near-infrared fluorescent compound that was activated by tumor-associated proteases for cathepsins B and H. Imaging experiments were performed 0-72 hours after intravenous injection of the probe in nude mice that bore human breast carcinoma (BT-20). RESULTS: The imaging system had a maximal spatial resolution of 60 microns, with a field of view of 14 cm2. The detection threshold of the nonquenched near-infrared fluorescent dye was subpicomolar in the imaging phantom experiments. In tissue, 250 pmol of fluorochrome was easily detected during the 10-second image acquisition. After intravenous injection of the probe into the tumor-bearing animals, tumors as small as 1 mm became detectable because of tumor-associated enzymatic activation of the quenched compound. CONCLUSION: Tumor proteases can be used as molecular targets, allowing visualization of millimeter-sized tumors. The development of this technology, probe design, and optical imaging systems hold promise for molecular imaging, cancer detection, and evaluation of treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Caspases: the executioners of apoptosis
COHEN, G. M. (1997) · Biochemical Journal · doi:10.1042/bj3260001 · Cited by 4,719
Matrix metalloproteinases and their inhibitors in connective tissue remodeling
Woessner, J. F. (1991) · The FASEB Journal · doi:10.1096/fasebj.5.8.1850705 · Cited by 3,282
Matrix Metalloproteinases: A Review
Birkedal-Hansen, H., Moore, W. G. I., Bodden, M. K., Windsor, L. J., Birkedal-Hansen, B., DeCarlo, A., & Engler, J. A. (1993) · Critical Reviews in Oral Biology & Medicine · doi:10.1177/10454411930040020401 · Cited by 2,970
In vivo imaging of tumors with protease-activated near-infrared fluorescent probes
Weissleder, R., Tung, C.-H., Mahmood, U., & Bogdanov, A. (1999) · Nature Biotechnology · doi:10.1038/7933 · Cited by 1,591
Self-citationIn Vivo Endoscopic Optical Biopsy with Optical Coherence Tomography
Tearney, G. J., Brezinski, M. E., Bouma, B. E., Boppart, S. A., Pitris, C., Southern, J. F., & Fujimoto, J. G. (1997) · Science · doi:10.1126/science.276.5321.2037 · Cited by 1,364
Bioluminescent indicators in living mammals
Contag, P. R., Olomu, I. N., Stevenson, D. K., & Contag, C. H. (1998) · Nature Medicine · doi:10.1038/nm0298-245 · Cited by 517
Brown, P. D. N., Bloxidge, R. E., Stuart, N. S. A., Galler, K. C., & Carmichael, J. (1993) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/85.7.574 · Cited by 294
Neri, D., Carnemolla, B., Nissim, A., Leprini, A., Querzè, G., Balza, E., Pini, A., Tarli, L., Halin, C., Neri, P., et al. (1997) · Nature Biotechnology · doi:10.1038/nbt1197-1271 · Cited by 282
Boas, D. A., O'Leary, M. A., Chance, B., & Yodh, A. G. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.11.4887 · Cited by 248
In vivo fluorescence imaging for tissue diagnostics
Andersson-Engels, S., Klinteberg, C. A., Svanberg, K., & Svanberg, S. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/5/006 · Cited by 245
Metalloproteinases in tumor progression: the contribution of MMP-9.
Himelstein, B. P., Cañete-Soler, R., Bernhard, E. J., Dw, D., & Muschel, R. J. (1994) · PubMed · Cited by 231
Optical Time-of-Flight and Absorbance Imaging of Biologic Media
Benaron, D. A., & Stevenson, D. K. (1993) · Science · doi:10.1126/science.8451643 · Cited by 230
CHANCE, B. (1998) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1998.tb08185.x · Cited by 216
Denmeade, S. R., Lou, W., Lövgren, J., Malm, J., Lilja, H. G., & Isaacs, J. T. (1997) · PubMed · Cited by 190
Bogdanov, A. A., Weissleder, R., Frank, H. W., Bogdanova, A. V., Nossif, N., Schaffer, B. K., Tsai, E., Papisov, M. I., & Brady, T. J. (1993) · Radiology · doi:10.1148/radiology.187.3.8497616 · Cited by 182
Self-citationRaman Spectroscopy and Fluorescence Photon Migration for Breast Cancer Diagnosis and Imaging
Manoharan, R., Shafer, K., Perelman, L., Wu, J., Chen, K., Deinum, G., Fitzmaurice, M., Myles, J., Crowe, J., Dasarl, R. R., et al. (1998) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1998.tb05160.x · Cited by 170
The Biochemistry of Cancer Dissemination
Price, J. T., Bonovich, M. T., Kohn, E. C., Welch, D. R., & Hershey, M. S. (1997) · Critical Reviews in Biochemistry and Molecular Biology · doi:10.3109/10409239709082573 · Cited by 167
Biological and Clinical Significance of Cathepsin D in Breast Cancer Metastasis
Garcia, M., Platet, N., Liaudet, E., Laurent, V., Derocq, D., Brouillet, J., & Rochefort, H. (1996) · STEM CELLS · doi:10.1002/stem.140642 · Cited by 158
Patterns of expression of metalloproteinases and their inhibitors in human malignant lymphomas.
Kossakowska, A. E., Urbanski, S. J., Watson, A. J., Hayden, L. J., & Edwards, D. R. (1993) · PubMed · Cited by 83
Advances in Optical Imaging of Biomedical Mediaa
Alfano, R. R., Demos, S. G., & Gayen, S. K. (1997) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1997.tb46200.x · Cited by 64
Long-circulating blood pool imaging agents
Bogdanov, A. A., Jr., Weissleder, R., & Brady, T. J. (1995) · Advanced Drug Delivery Reviews · doi:10.1016/0169-409x(95)00034-5 · Cited by 62
Self-citationAntibody-Mediated versus Nontargeted Delivery in a Human Small Cell Lung Carcinoma Model
Marecos, E., Weissleder, R., & Bogdanov, A. A., Jr. (1998) · Bioconjugate Chemistry · doi:10.1021/bc970146w · Cited by 58
Self-citationHebden, J. C., & Delpy, D. T. (1997) · British Journal of Radiology · doi:10.1259/bjr.1997.0026 · Cited by 54
Control of breast tumor cell growth using a targeted cysteine protease inhibitor.
Xing, R., Wu, F., & Mason, R. W. (1998) · PubMed · Cited by 28
Cited by
Molecular imaging in living subjects: seeing fundamental biological processes in a new light
Massoud, T. F., & Gambhir, S. S. (2003) · Genes & Development · doi:10.1101/gad.1047403 · Cited by 2,216
Shedding light onto live molecular targets
Weissleder, R., & Ntziachristos, V. (2003) · Nature Medicine · doi:10.1038/nm0103-123 · Cited by 1,909
Self-citationLooking and listening to light: the evolution of whole-body photonic imaging
Ntziachristos, V., Ripoll, J., Wang, L. V., & Weissleder, R. (2005) · Nature Biotechnology · doi:10.1038/nbt1074 · Cited by 1,557
Self-citationWeissleder, R., & Mahmood, U. (2001) · Radiology · doi:10.1148/radiology.219.2.r01ma19316 · Cited by 1,315
Self-citationAdvances in In Vivo Bioluminescence Imaging of Gene Expression
Contag, C. H., & Bachmann, M. H. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.111901.093336 · Cited by 870
Metadata
- Authors
- Mahmood, U., Tung, C.-H., Bogdanov, A., & Weissleder, R.
- Venue
- Radiology
- Published
- 1999-12
- Volume
- 213
- Issue
- 3
- Pages
- 866-870
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2050014887
- Cited by
- 301
- References
- 24
- FWCI
- 14.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.