Three-dimensional Systolic Strain Patterns in the Normal Human Left Ventricle: Characterization with Tagged MR Imaging
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
PURPOSE: To present a database of systolic three-dimensional (3D) strain evolution throughout the normal left ventricle (LV) in humans. MATERIALS AND METHODS: In 31 healthy volunteers, magnetic resonance (MR) tissue tagging and breath-hold MR imaging were used to generate and then detect the motion of transient fiducial markers (ie, tags) in the heart every 32 msec. Strain and motion were calculated from a 3D displacement field that was fit to the tag data. Special indexes of contraction and thickening that were based on multiple strain components also were evaluated. RESULTS: The temporal evolution of local strains was linear during the first half of systole. The peak shortening and thickening strain components were typically greatest in the anterolateral wall, increased toward the apex, and increased toward the endocardium. Shears and displacements were more spatially variable. The two specialized indexes of contraction and thickening had higher measurement precision and tighter normal ranges than did the traditional strain components. CONCLUSION: In this study, the authors noninvasively characterized the normal systolic ranges of 3D displacement and strain evolution throughout the human LV. Comparison against this multidimensional database may permit sensitive detection of systolic LV dysfunction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Human heart: tagging with MR imaging--a method for noninvasive assessment of myocardial motion.
Zerhouni, E. A., Parish, D. M., Rogers, W. J., Yang, A., & Shapiro, E. P. (1988) · Radiology · doi:10.1148/radiology.169.1.3420283 · Cited by 1,430
Self-citationMR imaging of motion with spatial modulation of magnetization.
Axel, L., & Dougherty, L. (1989) · Radiology · doi:10.1148/radiology.171.3.2717762 · Cited by 1,150
Mathematical model of geometry and fibrous structure of the heart
Nielsen, P. M., Le Grice, I. J., Smaill, B. H., & Hunter, P. J. (1991) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1991.260.4.h1365 · Cited by 657
Heart wall motion: improved method of spatial modulation of magnetization for MR imaging.
Axel, L., & Dougherty, L. (1989) · Radiology · doi:10.1148/radiology.172.2.2748813 · Cited by 597
Three-dimensional left ventricular deformation in hypertrophic cardiomyopathy.
Young, A. A., Kramer, C. M., Ferrari, V. A., Axel, L., & Reichek, N. (1994) · Circulation · doi:10.1161/01.cir.90.2.854 · Cited by 401
Waldman, L. K., Fung, Y. C., & Covell, J. W. (1985) · Circulation Research · doi:10.1161/01.res.57.1.152 · Cited by 363
Buchalter, M. B., Weiss, J. L., Rogers, W. J., Zerhouni, E. A., Weisfeldt, M. L., Beyar, R., & Shapiro, E. P. (1990) · Circulation · doi:10.1161/01.cir.81.4.1236 · Cited by 360
Self-citationIngels, N. B., Hansen, D. E., Daughters, G. T., Stinson, E. B., Alderman, E. L., & Miller, D. C. (1989) · Circulation Research · doi:10.1161/01.res.64.5.915 · Cited by 249
Ingels, N. B., Daughters, G. T., Stinson, E. B., & Alderman, E. L. (1975) · Circulation · doi:10.1161/01.cir.52.5.859 · Cited by 248
Palmon, L. C., Reichek, N., Yeon, S. B., Clark, N. R., Brownson, D., Hoffman, E., & Axel, L. (1994) · Circulation · doi:10.1161/01.cir.89.1.122 · Cited by 213
Cited by
Mor-Avi, V., Lang, R. M., Badano, L. P., Belohlavek, M., Cardim, N. M., Derumeaux, G., Galderisi, M., Marwick, T., Nagueh, S. F., Sengupta, P. P., et al. (2011) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2011.01.015 · Cited by 1,254
Mor-Avi, V., Lang, R. M., Badano, L. P., Belohlavek, M., Cardim, N. M., Derumeaux, G., Galderisi, M., Marwick, T., Nagueh, S. F., Sengupta, P. P., et al. (2011) · European Journal of Echocardiography · doi:10.1093/ejechocard/jer021 · Cited by 1,080
Measurement of Ventricular Torsion by Two-Dimensional Ultrasound Speckle Tracking Imaging
Notomi, Y., Shiota, T., Popović, Z. B., Weaver, J. A., Oryszak, S. J., Greenberg, N. L., White, R. D., Thomas, J. D., Setser, R. M., White, R. D., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.02.082 · Cited by 767
Normal values for cardiovascular magnetic resonance in adults and children
Kawel-Boehm, N., Maceira, A., Valsangiacomo-Buechel, E. R., Vogel-Claussen, J., Turkbey, E. B., Williams, R., Plein, S., Tee, M., Eng, J., & Bluemke, D. A. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0111-7 · Cited by 746
Global longitudinal strain: a novel index of left ventricular systolic function
Reisner, S. A., Lysyansky, P., Agmon, Y., Mutlak, D., Lessick, J., & Friedman, Z. (2004) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2004.02.011 · Cited by 735
Helle-Valle, T., Crosby, J., Edvardsen, T., Lyseggen, E., Amundsen, B. H., Smith, H.-J., Rosen, B. D., Lima, J. A. C., Torp, H., Ihlen, H., et al. (2005) · Circulation · doi:10.1161/circulationaha.104.531558 · Cited by 705
Xu, L., Gutbrod, S. R., Bonifas, A. P., Su, Y., Sulkin, M. S., Lu, N., Chung, H.-J., Jang, K.-I., Liu, Z., Ying, M., et al. (2014) · Nature Communications · doi:10.1038/ncomms4329 · Cited by 634
Kawel-Boehm, N., Hetzel, S. J., Ambale-Venkatesh, B., Captur, G., Francois, C. J., Jerosch-Herold, M., Salerno, M., Teague, S. D., Valsangiacomo-Buechel, E., van der Geest, R. J., et al. (2020) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-020-00683-3 · Cited by 610
Pedrizzetti, G., Claus, P., Kilner, P. J., & Nagel, E. (2016) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-016-0269-7 · Cited by 416
Ventricular untwisting: a temporal link between left ventricular relaxation and suction
Notomi, Y., Popović, Z. B., Yamada, H., Wallick, D. W., Martin, M. G., Oryszak, S. J., Shiota, T., Greenberg, N. L., & Thomas, J. D. (2008) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00975.2007 · Cited by 307
Reeder, S. B., Wintersperger, B. J., Dietrich, O., Lanz, T., Greiser, A., Reiser, M. F., Glazer, G. M., & Schoenberg, S. O. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20636 · Cited by 302
Spatio-temporal nonrigid registration for ultrasound cardiac motion estimation
Ledesma-Carbayo, M. J., Kybic, J., Desco, M., Santos, A., Suhling, M., Hunziker, P., & Unser, M. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.852050 · Cited by 290
Augustine, D., Lewandowski, A. J., Lazdam, M., Rai, A., Francis, J., Myerson, S., Noble, A., Becher, H., Neubauer, S., Petersen, S. E., et al. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-8 · Cited by 285
Chan, J., Hanekom, L., Wong, C., Leano, R., Cho, G.-Y., & Marwick, T. H. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.07.050 · Cited by 281
Ibrahim, E.-S. H. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-36 · Cited by 274
Corridor4DM: The Michigan method for quantitative nuclear cardiology
Ficaro, E. P., Lee, B. C., Kritzman, J. N., & Corbett, J. R. (2007) · Journal of Nuclear Cardiology · doi:10.1016/j.nuclcard.2007.06.006 · Cited by 255
Popović, Z. B., Kwon, D. H., Mishra, M., Buakhamsri, A., Greenberg, N. L., Thamilarasan, M., Flamm, S. D., Thomas, J. D., Lever, H. M., & Desai, M. Y. (2008) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2008.09.011 · Cited by 252
Myocardial strain measurement with feature-tracking cardiovascular magnetic resonance: normal values
Taylor, R. J., Moody, W. E., Umar, F., Edwards, N. C., Taylor, T. J., Stegemann, B., Townend, J. N., Hor, K. N., Steeds, R. P., Mazur, W., et al. (2015) · European Heart Journal – Cardiovascular Imaging · doi:10.1093/ehjci/jev006 · Cited by 251
Notomi, Y., Setser, R. M., Shiota, T., Martin-Miklovic, M. G., Weaver, J. A., Popović, Z. B., Yamada, H., Greenberg, N. L., White, R. D., & Thomas, J. D. (2005) · Circulation · doi:10.1161/01.cir.0000157151.10971.98 · Cited by 235
Myocardial Strain and Torsion Quantified by Cardiovascular Magnetic Resonance Tissue Tagging
Götte, M. J. W., Germans, T., Rüssel, I. K., Zwanenburg, J. J. M., Marcus, J. T., van Rossum, A. C., & van Veldhuisen, D. J. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.07.048 · Cited by 222
Contactless Electrocardiogram Monitoring With Millimeter Wave Radar
Chen, J., Zhang, D., Wu, Z., Zhou, F., Sun, Q., & Chen, Y. (2024) · IEEE Transactions on Mobile Computing · doi:10.1109/tmc.2022.3214721 · Cited by 210
“Many techniques have been investigated to study this motion directly, including tagged magnetic resonance imaging (tagged MRI) [11], tissue Doppler imaging (TDI) [12], speckle tracking imaging [13], seismocardiography (SCG) [14] and gyrocar-diography (GCG) [15].”
MethodWeidemann, F., Eyskens, B., Jamal, F., Mertens, L., Kowalski, M., D'Hooge, J., Bijnens, B., Gewillig, M., Rademakers, F., Hatle, L., et al. (2002) · Journal of the American Society of Echocardiography · doi:10.1067/mje.2002.116532 · Cited by 207
Myocardial tissue tagging with cardiovascular magnetic resonance
Shehata, M. L., Cheng, S., Osman, N. F., Bluemke, D. A., & Lima, J. A. (2009) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-11-55 · Cited by 193
Sun, J. P., Popović, Z. B., Greenberg, N. L., Xu, X.-F., Asher, C. R., Stewart, W. J., & Thomas, J. D. (2004) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2003.10.001 · Cited by 178
Jafari Tadi, M., Lehtonen, E., Saraste, A., Tuominen, J., Koskinen, J., Teräs, M., Airaksinen, J., Pänkäälä, M., & Koivisto, T. (2017) · Scientific Reports · doi:10.1038/s41598-017-07248-y · Cited by 174
Mansi, T., Pennec, X., Sermesant, M., Delingette, H., & Ayache, N. (2011) · International Journal of Computer Vision · doi:10.1007/s11263-010-0405-z · Cited by 174
“The amplitude of the radial strain was more plausible and the temporal variation patterns of the circumferential and longitudinal strains were consistent with the clinical literature (Moore et al, 2000).”
Benchmarking framework for myocardial tracking and deformation algorithms: An open access database
Tobon-Gomez, C., De Craene, M., McLeod, K., Tautz, L., Shi, W., Hennemuth, A., Prakosa, A., Wang, H., Carr-White, G., Kapetanakis, S., et al. (2013) · Medical Image Analysis · doi:10.1016/j.media.2013.03.008 · Cited by 171
“Finally, according to reported measurements (Moore et al., 2000), peak values of strain curves should reach up to 45% for radial strain, -20% for circumferential strain and -16% for longitudinal strain.”
BackgroundResultInfluentialAge-related Changes in Left Ventricular Twist Assessed by Two-dimensional Speckle-tracking Imaging
Takeuchi, M., Nakai, H., Kokumai, M., Nishikage, T., Otani, S., & Lang, R. M. (2006) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2006.04.011 · Cited by 167
Takeuchi, M., Nishikage, T., Nakai, H., Kokumai, M., Otani, S., & Lang, R. M. (2007) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2006.06.019 · Cited by 163
Does subclinical hypothyroidism affect cardiac pump performance?
Ripoli, A., Pingitore, A., Favilli, B., Bottoni, A., Turchi, S., Osman, N. F., De Marchi, D., Lombardi, M., L'Abbate, A., & Iervasi, G. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.10.044 · Cited by 157
Fibrous scaffolds for building hearts and heart parts
Capulli, A. K., MacQueen, L. A., Sheehy, S. P., & Parker, K. K. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.11.020 · Cited by 130
Løgstrup, B. B., Nielsen, J. M., Kim, W. Y., & Poulsen, S. H. (2016) · European Heart Journal – Cardiovascular Imaging · doi:10.1093/ehjci/jev302 · Cited by 105
Metadata
- Authors
- Moore, C. C., Lugo-Olivieri, C. H., McVeigh, E. R., & Zerhouni, E. A.
- Venue
- Radiology
- Published
- 2000-02
- Volume
- 214
- Issue
- 2
- Pages
- 453-466
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W1999522789
- Cited by
- 421
- References
- 23
- FWCI
- 8.46
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.