Introduction to the Language of Three-dimensional Imaging with Multidetector CT
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
The recent proliferation of multi-detector row computed tomography (CT) has led to an increase in the creation and interpretation of images in planes other than the traditional axial plane. Powerful three-dimensional (3D) applications improve the utility of detailed CT data but also create confusion among radiologists, technologists, and referring clinicians when trying to describe a particular method or type of image. Designing examination protocols that optimize data quality and radiation dose to the patient requires familiarity with the concepts of beam collimation and section collimation as they apply to multi-detector row CT. A basic understanding of the time-limited nature of projection data and the need for thin-section axial reconstruction for 3D applications is necessary to use the available data effectively in clinical practice. The axial reconstruction data can be used to create nonaxial two-dimensional images by means of multiplanar reformation. Multiplanar images can be thickened into slabs with projectional techniques such as average, maximum, and minimum intensity projection; ray sum; and volume rendering. By assigning a full spectrum of opacity values and applying color to the tissue classification system, volume rendering provides a robust and versatile data set for advanced imaging applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Display of surfaces from volume data
Levoy, M. (1988) · IEEE Computer Graphics and Applications · doi:10.1109/38.511 · Cited by 2,446
Drebin, R. A., Carpenter, L., & Hanrahan, P. (1988) · ACM SIGGRAPH Computer Graphics · doi:10.1145/378456.378484 · Cited by 1,612
Strategies for CT Radiation Dose Optimization
Kalra, M. K., Maher, M. M., Toth, T. L., Hamberg, L. M., Blake, M. A., Shepard, J.-A., & Saini, S. (2004) · Radiology · doi:10.1148/radiol.2303021726 · Cited by 1,080
Multi‐slice helical CT: Scan and reconstruction
Hu, H. (1999) · Medical Physics · doi:10.1118/1.598470 · Cited by 563
Three-dimensional Volume Rendering of Spiral CT Data: Theory and Method
Calhoun, P. S., Kuszyk, B. S., Heath, D. G., Carley, J. C., & Fishman, E. K. (1999) · RadioGraphics · doi:10.1148/radiographics.19.3.g99ma14745 · Cited by 550
Four Multidetector-Row Helical CT: Image Quality and Volume Coverage Speed
Hu, H., He, H. D., Foley, W. D., & Fox, S. H. (2000) · Radiology · doi:10.1148/radiology.215.1.r00ap3755 · Cited by 509
Perspective volume rendering of CT and MR images: applications for endoscopic imaging.
Rubin, G. D., Beaulieu, C. F., Argiro, V., Ringl, H., Norbash, A., Feller, J. F., Dake, M. D., Jeffrey, R. B., & Napel, S. A. (1996) · Radiology · doi:10.1148/radiology.199.2.8668772 · Cited by 397
Performance evaluation of a multi-slice CT system
McCollough, C. H., & Zink, F. E. (1999) · Medical Physics · doi:10.1118/1.598777 · Cited by 386
CT angiography with spiral CT and maximum intensity projection.
Napel, S. A., Marks, M. P., Rubin, G. D., et al. (1992) · Radiology · doi:10.1148/radiology.185.2.1410382 · Cited by 364
Three-dimensional spiral CT angiography of the abdomen: initial clinical experience.
Rubin, G. D., Dake, M. D., Napel, S. A., McDonnell, C. H., & Jeffrey, R. B. (1993) · Radiology · doi:10.1148/radiology.186.1.8416556 · Cited by 362
Cited by
Dual-Energy CT for the Musculoskeletal System
Mallinson, P. I., Coupal, T. M., McLaughlin, P. D., Nicolaou, S., Munk, P. L., & Ouellette, H. A. (2016) · Radiology · doi:10.1148/radiol.2016151109 · Cited by 242
Metadata
- Authors
- Dalrymple, N. C., Prasad, S. R., Freckleton, M. W., & Chintapalli, K. N.
- Venue
- RadioGraphics
- Published
- 2005-09
- Volume
- 25
- Issue
- 5
- Pages
- 1409-1428
- ISSN
- 0271-5333 (ISSN-L)
- 1527-1323
- OpenAlex
- W2170925826
- Cited by
- 218
- References
- 22
- FWCI
- 9.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).