The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Radiation Dose Modulation Techniques in the Multidetector CT Era: From Basics to Practice
Abstract
Radiation exposure to the patient has become a concern for the radiologist in the multidetector computed tomography (CT) era. With the introduction of faster multidetector CT scanners, various techniques have been developed to reduce the radiation dose to the patient; one method is automatic exposure control (AEC). AEC systems make use of different types of control, including patient-size AEC, z-axis AEC, rotational or angular AEC, or a combination of two or more of these types. AEC systems operate on the basis of several methods: standard deviation, noise index, reference milliamperage, and reference image. A clear understanding of how to use different AEC systems on different multidetector CT scanners will allow users to modulate radiation dose, reduce photon starvation artifacts, and maintain image quality throughout the body. Further development of AEC systems and their successful introduction into clinical practice will require user education and good communication between users and manufacturers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760289 · Cited by 3,222
American College of Radiology White Paper on Radiation Dose in Medicine
Amis, E. S., Butler, P. F., Applegate, K. E., Birnbaum, S. B., Brateman, L. F., Hevezi, J. M., Mettler, F. A., Morin, R. L., Pentecost, M. J., Smith, G. G., et al. (2007) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2007.03.002 · Cited by 902
Techniques and Applications of Automatic Tube Current Modulation for CT
Kalra, M. K., Maher, M. M., Toth, T. L., Schmidt, B., Westerman, B. L., Morgan, H. T., & Saini, S. (2004) · Radiology · doi:10.1148/radiol.2333031150 · Cited by 725
A method for describing the doses delivered by transmission x-ray computed tomography
Shope, T. B., Gagne, R. M., & Johnson, G. C. (1981) · Medical Physics · doi:10.1118/1.594995 · Cited by 435
Mulkens, T. H., Bellinck, P., Baeyaert, M., Ghysen, D., Van Dijck, X., Mussen, E., Venstermans, C., & Termote, J.-L. (2005) · Radiology · doi:10.1148/radiol.2363041220 · Cited by 354
Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurements
Kalender, W. A., Wolf, H., & Suess, C. (1999) · Medical Physics · doi:10.1118/1.598738 · Cited by 345
Dose reduction in CT by anatomically adapted tube current modulation. I. Simulation studies
Gies, M., Kalender, W. A., Wolf, H., Suess, C., & Madsen, M. T. (1999) · Medical Physics · doi:10.1118/1.598779 · Cited by 306
McCollough, C. H., & Schueler, B. A. (2000) · Medical Physics · doi:10.1118/1.598948 · Cited by 291
Influence of patient age on normalized effective doses calculated for CT examinations
Khursheed, A., Hillier, M. C., Shrimpton, P. C., & Wall, B. F. (2002) · The British Journal of Radiology · doi:10.1259/bjr.75.898.750819 · Cited by 191
(1991) · Annals of the ICRP · doi:10.1016/0146-6453(91)90065-o · Cited by 189
Cited by
Han, B. K., Rigsby, C. K., Hlavacek, A., Leipsic, J., Nicol, E. D., Siegel, M. J., Bardo, D., Abbara, S., Ghoshhajra, B., Lesser, J. R., et al. (2015) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2015.07.004 · Cited by 211
Han, B. K., Rigsby, C. K., Leipsic, J., Bardo, D., Abbara, S., Ghoshhajra, B., Lesser, J. R., Raman, S. V., Crean, A. M., Nicol, E. D., et al. (2015) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2015.07.007 · Cited by 158
Relationships of radiation dose indices with body size indices in adult body computed tomography
Inoue, Y., Itoh, H., Nagahara, K., Hata, H., & Mitsui, K. (2023) · Tomography · doi:10.3390/tomography9040110 · Cited by 16
Metadata
- Authors
- Lee, C. H., Goo, J. M., Ye, H. J., Ye, S.-J., Park, C. M., Chun, E. J., & Im, J.-G.
- Venue
- RadioGraphics
- Published
- 2008-09
- Volume
- 28
- Issue
- 5
- Pages
- 1451-1459
- ISSN
- 0271-5333 (ISSN-L)
- 1527-1323
- OpenAlex
- W1997587561
- Cited by
- 314
- References
- 11
- FWCI
- 12.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Radiation Dose Modulation Techniques in the Multidetector CT Era: From Basics to Practice. https://app.cochat.ai/papers/10.1148/rg.285075075
- The paper
- Lee, C. H., Goo, J. M., Ye, H. J., Ye, S.-J., Park, C. M., Chun, E. J., & Im, J.-G. (2008). Radiation Dose Modulation Techniques in the Multidetector CT Era: From Basics to Practice. RadioGraphics. https://doi.org/10.1148/rg.285075075
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.