Advancements in MR Imaging of the Prostate: From Diagnosis to Interventions
Open accessAbstract
Prostate cancer is the most frequently diagnosed cancer in males and the second leading cause of cancer-related death in men. Assessment of prostate cancer can be divided into detection, localization, and staging; accurate assessment is a prerequisite for optimal clinical management and therapy selection. Magnetic resonance (MR) imaging has been shown to be of particular help in localization and staging of prostate cancer. Traditional prostate MR imaging has been based on morphologic imaging with standard T1-weighted and T2-weighted sequences, which has limited accuracy. Recent advances include additional functional and physiologic MR imaging techniques (diffusion-weighted imaging, MR spectroscopy, and perfusion imaging), which allow extension of the obtainable information beyond anatomic assessment. Multiparametric MR imaging provides the highest accuracy in diagnosis and staging of prostate cancer. In addition, improvements in MR imaging hardware and software (3-T vs 1.5-T imaging) continue to improve spatial and temporal resolution and the signal-to-noise ratio of MR imaging examinations. Another recent advancement in the field is MR imaging guidance for targeted prostate biopsy, which is an alternative to the current standard of transrectal ultrasonography-guided systematic biopsy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jemal, A., Siegel, R., Ward, E., Hao, Y., Xu, J., Murray, T., & Thun, M. J. (2008) · CA: A Cancer Journal for Clinicians · doi:10.3322/ca.2007.0010 · Cited by 10,188
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912
Tofts, P. S., Brix, G., Buckley, D. L., Evelhoch, J. L., Henderson, E., Knopp, M. V., Larsson, H. B. W., Lee, T.-Y., Mayr, N. A., Parker, G. J. M., et al. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199909)10:3<223::aid-jmri2>3.0.co;2-s · Cited by 3,143
Thompson, I. M., Pauler, D. K., Goodman, P. J., Tangen, C. M., Lucia, M. S., Parnes, H. L., Minasian, L. M., Ford, L. G., Lippman, S. M., Crawford, E. D., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa031918 · Cited by 2,446
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
Modeling tracer kinetics in dynamic Gd‐DTPA MR imaging
Tofts, P. S. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070113 · Cited by 1,478
Spatial Localization in NMR Spectroscopy in Vivo
BOTTOMLEY, P. A. (1987) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1987.tb32915.x · Cited by 1,378
McNeal, J. E., Redwine, E. A., Freiha, F. S., & Stamey, T. A. (1988) · The American Journal of Surgical Pathology · doi:10.1097/00000478-198812000-00001 · Cited by 1,182
(2024) · American Journal of Neuroradiology · doi:10.3174/ajnr.45-12.s8 · Cited by 890
Stamey, T. A., Freiha, F. S., McNeal, J. E., Redwine, E. A., Whittemore, A. S., & Schmid, H.-P. (1993) · Cancer · doi:10.1002/1097-0142(19930201)71:3+<933::aid-cncr2820711408>3.0.co;2-l · Cited by 799
Imaging Prostate Cancer: A Multidisciplinary Perspective
Hricak, H., Choyke, P. L., Eberhardt, S. C., Leibel, S. A., & Scardino, P. T. (2007) · Radiology · doi:10.1148/radiol.2431030580 · Cited by 601
Tumour phospholipid metabolism
Podo, F. (1999) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199911)12:7<413::aid-nbm587>3.0.co;2-u · Cited by 579
An Update of the Gleason Grading System
Epstein, J. I. (2010) · Journal of Urology · doi:10.1016/j.juro.2009.10.046 · Cited by 533
Kozlowski, P., Chang, S. D., Jones, E. C., Berean, K. W., Chen, H., & Goldenberg, S. L. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20626 · Cited by 267
Prostate Cancer Tumor Volume: Measurement with Endorectal MR and MR Spectroscopic Imaging
Coakley, F. V., Kurhanewicz, J., Lu, Y., Jones, K. D., Swanson, M. G., Chang, S. D., Carroll, P. R., & Hricak, H. (2002) · Radiology · doi:10.1148/radiol.2231010575 · Cited by 258
Tamada, T., Sone, T., Jo, Y., Toshimitsu, S., Yamashita, T., Yamamoto, A., Tanimoto, D., & Ito, K. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21503 · Cited by 258
Jung, J. A., Coakley, F. V., Vigneron, D. B., Swanson, M. G., Qayyum, A., WEINBERG, V. K., Jones, K. D., Carroll, P. R., & Kurhanewicz, J. V. (2004) · Radiology · doi:10.1148/radiol.2333030672 · Cited by 213
Single‐voxel proton MRS of the human brain at 1.5T and 3.0T
Barker, P. B., Hearshen, D. O., & Boska, M. D. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1104 · Cited by 208
Dynamic contrast enhanced MRI in prostate cancer
Alonzi, R., Padhani, A. R., & Allen, C. (2007) · European Journal of Radiology · doi:10.1016/j.ejrad.2007.06.028 · Cited by 204
“MRI Stealth” robot for prostate interventions
Stoianovici, D., Song, D., Petrisor, D., Ursu, D., Mazilu, D., Mutener, M., Schar, M., & Patriciu, A. (2007) · Minimally Invasive Therapy & Allied Technologies · doi:10.1080/13645700701520735 · Cited by 200
Self-citationNoworolski, S. M., Vigneron, D. B., Chen, A. P., & Kurhanewicz, J. V. (2008) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2008.01.033 · Cited by 103
Prostate cancer vs. post‐biopsy hemorrhage: Diagnosis with T2‐ and diffusion‐weighted imaging
Rosenkrantz, A. B., Kopec, M., Kong, X., Melamed, J., Dakwar, G. R., Babb, J. S., & Taouli, B. A. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22172 · Cited by 93
Kim, J. H., Kim, J. K., Park, B., Kim, N., & Cho, K. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21513 · Cited by 88
Angiogenesis imaging in the management of prostate cancer
Padhani, A. R., Harvey, C. J., & Cosgrove, D. O. (2005) · Nature Clinical Practice Urology · doi:10.1038/ncpuro0356 · Cited by 66
Bone imaging in prostate cancer
Dotan, Z. (2008) · Nature Clinical Practice Urology · doi:10.1038/ncpuro1190 · Cited by 30
Slawin, K. M., DiBlasio, C. J., & Kattan, M. W. (2004) · Europe PMC (PubMed Central) · Cited by 6
Optimal cost-effective staging evaluations in prostate cancer
Lacy, G. L., Soderdahl, D. W., & Hernández, J. (2007) · Current Urology Reports · doi:10.1007/s11934-007-0005-9 · Cited by 5
Cited by
Beyond PSA: The Next Generation of Prostate Cancer Biomarkers
Prensner, J. R., Rubin, M. A., Wei, J. T., & Chinnaiyan, A. M. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3003180 · Cited by 472
Metadata
- Authors
- Bonekamp, D., Jacobs, M. A., El-Khouli, R., Stoianovici, D., & Macura, K. J.
- Venue
- RadioGraphics
- Published
- 2011-05
- Volume
- 31
- Issue
- 3
- Pages
- 677-703
- ISSN
- 0271-5333 (ISSN-L)
- 1527-1323
- OpenAlex
- W2150230257
- Cited by
- 254
- References
- 27
- FWCI
- 17.32
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).