Electrochemical Conversion of Carbon Dioxide to Formate in Alkaline Polymer Electrolyte Membrane Cells
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper is about the continuous electrochemical conversion of carbon dioxide to formate in a polymer electrolyte membrane cell using an alkaline ion-exchange membrane sandwiched between two catalyzed electrodes.This type of cell configuration allows carbon dioxide conversion to occur at high efficiencies and is particularly attractive for large-scale implementation.Formate was produced at high efficiency, and hydrogen evolution was suppressed with lead and indium as catalysts.The production of formate was monitored by UV-visible spectroscopy.During short experimental runs, the faradaic efficiency of formate production was as high as 80%.The faradaic efficiency was strongly dependent on the concentrations of carbon dioxide, bicarbonate, and carbonate at the surface of the electrodes.Low concentrations of carbon dioxide in the reactant feed led to the mass transport limitations and hence low faradaic efficiencies.The results show that mass transport limitations can be mitigated and high efficiencies can be realized by conducting the electrolysis in a pulsed mode.An alkaline membrane-based flow cell that ensures abundant availability of carbon dioxide to the electrodes can be a cost-effective and efficient approach for the continuous production of fuels from sunlight, storing of renewable energy, and lowering carbon dioxide levels in the atmosphere.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Delacourt, C., Ridgway, P. L., Kerr, J. B., & Newman, J. (2008) · Journal of The Electrochemical Society · doi:10.1149/1.2801871 · Cited by 442
Cited by
A review of catalysts for the electroreduction of carbon dioxide to produce low-carbon fuels
Qiao, J., Liu, Y., Hong, F., & Zhang, J. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60323g · Cited by 2,990
Kondratenko, E. V., Mul, G., Baltrusaitis, J., Larrazábal, G. O., & Pérez-Ramírez, J. (2013) · Energy & Environmental Science · doi:10.1039/c3ee41272e · Cited by 1,802
Electrocatalysis for CO 2 conversion: from fundamentals to value-added products
Wang, G., Chen, J., Ding, Y., Cai, P., Yi, L., Li, Y., Tu, C., Hou, Y., Wen, Z., & Dai, L. (2021) · Chemical Society Reviews · doi:10.1039/d0cs00071j · Cited by 1,295
Min, X., & Kanan, M. W. (2015) · Journal of the American Chemical Society · doi:10.1021/ja511890h · Cited by 541
Designing anion exchange membranes for CO2 electrolysers
Salvatore, D. A., Gabardo, C. M., Reyes, A., O’Brien, C. P., Holdcroft, S., Pintauro, P., Bahar, B., Hickner, M., Bae, C., Sinton, D., et al. (2021) · Nature Energy · doi:10.1038/s41560-020-00761-x · Cited by 477
Towards membrane-electrode assembly systems for CO2 reduction: a modeling study
Weng, L.-C., Bell, A. T., & Weber, A. Z. (2019) · Energy & Environmental Science · doi:10.1039/c9ee00909d · Cited by 452
Electrochemical CO2 Reduction: Recent Advances and Current Trends
Jones, J., Prakash, G. K. S., & Olah, G. A. (2014) · Israel Journal of Chemistry · doi:10.1002/ijch.201400081 · Cited by 425
Continuous-flow electroreduction of carbon dioxide
Endrődi, B., Bencsik, G., Darvas, F., Jones, R., Rajeshwar, K., & Janáky, C. (2017) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2017.05.005 · Cited by 386
Electrolytic cell design for electrochemical CO2 reduction
Liang, S., Altaf, N., Huang, L., Gao, Y., & Wang, Q. (2020) · Journal of CO2 Utilization · doi:10.1016/j.jcou.2019.09.007 · Cited by 362
Electrochemical conversion of CO2 to formic acid utilizing Sustainion™ membranes
Yang, H., Kaczur, J. J., Sajjad, S. D., & Masel, R. I. (2017) · Journal of CO2 Utilization · doi:10.1016/j.jcou.2017.04.011 · Cited by 357
Controlling H+ vs CO2 Reduction Selectivity on Pb Electrodes
Lee, C. H., & Kanan, M. W. (2015) · ACS Catalysis · doi:10.1021/cs5017672 · Cited by 341
Current technology development for CO2 utilization into solar fuels and chemicals: A review
Mustafa, A., Lougou, B. G., Shuai, Y., Wang, Z., & Tan, H. (2020) · Journal of Energy Chemistry · doi:10.1016/j.jechem.2020.01.023 · Cited by 336
Electroreduction of CO 2 : Advances in the Continuous Production of Formic Acid and Formate
Fernández-Caso, K., Díaz-Sainz, G., Alvarez-Guerra, M., & Irabien, A. (2023) · ACS Energy Letters · doi:10.1021/acsenergylett.3c00489 · Cited by 329
Recent progress in the electrochemical conversion and utilization of CO2
Spinner, N. S., Vega, J. A., & Mustain, W. E. (2012) · Catal. Sci. Technol. · doi:10.1039/c1cy00314c · Cited by 311
The Drive to Life on Wet and Icy Worlds
Russell, M. J., Barge, L. M., Bhartia, R., Bocanegra, D., Bracher, P. J., Branscomb, E., Kidd, R., McGlynn, S., Meier, D. H., Nitschke, W., et al. (2014) · Astrobiology · doi:10.1089/ast.2013.1110 · Cited by 288
“The abiotic reduction of CO2 to formaldehyde in aqueous solution is stymied by thermodynamic barriers so steep that even electrochemical efforts have failed the ascent (Maden, 2000; Vladimirov et al., 2004; Narayanan et al., 2011; cf. Schoonen et al., 1999).”
Wu, J., Risalvato, F. G., Ke, F.-S., Pellechia, P. J., & Zhou, X.-D. (2012) · Journal of The Electrochemical Society · doi:10.1149/2.049207jes · Cited by 216
Rational Design of Ag‐Based Catalysts for the Electrochemical CO2 Reduction to CO: A Review
Sun, D., Xu, X., Qin, Y., Jiang, S. P., & Shao, Z. (2020) · ChemSusChem · doi:10.1002/cssc.201902061 · Cited by 204
Lv, W., Zhang, R., Gao, P., & Lei, L. (2014) · Journal of Power Sources · doi:10.1016/j.jpowsour.2013.12.063 · Cited by 200
Electrochemical reduction of CO2 into formate/formic acid: A review of cell design and operation
Ewis, D., Arsalan, M., Khaled, M., Pant, D., Ba-Abbad, M. M., Amhamed, A., & El-Naas, M. H. (2023) · Separation and Purification Technology · doi:10.1016/j.seppur.2023.123811 · Cited by 197
The inevitable journey to being
Russell, M. J., Nitschke, W., & Branscomb, E. (2013) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2012.0254 · Cited by 174
“Moreover, laboratory experiments involving the reduction of carbon dioxide in aqueous conditions, evenwhen driven electrochemically, normally stall at formate [149].”
BackgroundElectrochemical reduction of CO2 over Sn-Nafion® coated electrode for a fuel-cell-like device
Prakash, G. K. S., Viva, F. A., & Olah, G. A. (2013) · Journal of Power Sources · doi:10.1016/j.jpowsour.2012.09.036 · Cited by 172
Aeshala, L. M., Uppaluri, R. G., & Verma, A. (2013) · Journal of CO2 Utilization · doi:10.1016/j.jcou.2013.09.004 · Cited by 99
Effect of solid polymer electrolyte on electrochemical reduction of CO2
Aeshala, L. M., Rahman, S. U., & Verma, A. (2012) · Separation and Purification Technology · doi:10.1016/j.seppur.2011.12.030 · Cited by 89
“[18] studied the continuous electrochemical reduction of carbon dioxide to formate in a polymer electrolyte membrane cell using an alkaline ion-exchange membrane.”
BackgroundMethodWang, G., Pan, J., Jiang, S. P., & Yang, H. (2018) · Journal of CO2 Utilization · doi:10.1016/j.jcou.2017.11.010 · Cited by 84
Sebastián, D., Palella, A., Baglio, V., Spadaro, L., Siracusano, S., Negro, P., Niccoli, F., & Aricò, A. S. (2017) · Electrochimica Acta · doi:10.1016/j.electacta.2017.04.119 · Cited by 52
Electrochemical approach for biogas upgrading
Pasternak, G. (2021) · Emerging Technologies and Biological Systems for Biogas Upgrading · doi:10.1016/b978-0-12-822808-1.00009-x · Cited by 12
Metadata
- Authors
- Narayanan, S. R., Haines, B., Soler, J., & Valdez, T. I.
- Venue
- Journal of The Electrochemical Society
- Publisher
- The Electrochemical Society
- Published
- 2011
- Volume
- 158
- Issue
- 2
- Pages
- A167
- ISSN
- 0013-4651 (ISSN-L)
- OpenAlex
- W1999702197
- Cited by
- 145
- References
- 1
- FWCI
- 2.52
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.