The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Twisting integrin receptors increases endothelin-1 gene expression in endothelial cells
Abstract
A magnetic twisting stimulator was developed based on the previously published technique of magnetic twisting cytometry. Using ligand-coated ferromagnetic microbeads, this device can apply mechanical stresses with varying amplitudes, duration, frequencies, and waveforms to specific cell surface receptors. Biochemical and biological responses of the cells to the mechanical stimulation can be assayed. Twisting integrin receptors with RGD (Arg-Gly-Asp)-containing peptide-coated beads increased endothelin-1 (ET-1) gene expression by >100%. In contrast, twisting scavenger receptors with acetylated low-density lipoprotein-coated beads or twisting HLA antigen with anti-HLA antibody-coated beads did not lead to alterations in ET-1 gene expression. In situ hybridization showed that the increase in ET-1 mRNA was localized in the cells that were stressed with the RGD-coated beads. Blocking stretch-activated ion channels with gadolinium, chelating Ca 2+with EGTA, or inhibiting tyrosine phosphorylation with genistein abolished twist-induced ET-1 mRNA elevation. Abolishing cytoskeletal tension with an inhibitor of the myosin ATPase, with an inhibitor of myosin light chain kinase, or with an actin microfilament disrupter blocked twisted-induced increases in ET-1 expression. Our results are consistent with the hypothesis that the molecular structural linkage of integrin-cytoskeleton is an important pathway for stress-induced ET-1 gene expression.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Flow-mediated endothelial mechanotransduction
Davies, P. F. (1995) · Physiological Reviews · doi:10.1152/physrev.1995.75.3.519 · Cited by 2,802
Cited by
Universal physical responses to stretch in the living cell
Trepat, X., Deng, L., An, S. S., Navajas, D., Tschumperlin, D. J., Gerthoffer, W. T., Butler, J. P., & Fredberg, J. J. (2007) · Nature · doi:10.1038/nature05824 · Cited by 699
Ingber, D. E. (2002) · Circulation Research · doi:10.1161/01.res.0000039537.73816.e5 · Cited by 621
Cell mechanics and mechanotransduction: pathways, probes, and physiology
Huang, H., Kamm, R. D., & Lee, R. T. (2004) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00559.2003 · Cited by 548
Mechanotransduction: All Signals Point to Cytoskeleton, Matrix, and Integrins
Alenghat, F. J., & Ingber, D. E. (2002) · Science's STKE · doi:10.1126/stke.2002.119.pe6 · Cited by 494
Tensegrity, cellular biophysics, and the mechanics of living systems
Ingber, D. E., Wang, N., & Stamenović, D. (2014) · Reports on Progress in Physics · doi:10.1088/0034-4885/77/4/046603 · Cited by 485
Self-citation
Metadata
- Authors
- Chen, J., Fabry, B., Schiffrin, E. L., & Wang, N.
- Venue
- American Journal of Physiology-Cell Physiology
- Publisher
- American Physiological Society
- Published
- 2001-06-01
- Volume
- 280
- Issue
- 6
- Pages
- C1475-C1484
- ISSN
- 0363-6143 (ISSN-L)
- 1522-1563
- OpenAlex
- W1849316866
- Cited by
- 200
- References
- 1
- FWCI
- 5.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Twisting integrin receptors increases endothelin-1 gene expression in endothelial cells. https://app.cochat.ai/papers/10.1152/ajpcell.2001.280.6.c1475
- The paper
- Chen, J., Fabry, B., Schiffrin, E. L., & Wang, N. (2001). Twisting integrin receptors increases endothelin-1 gene expression in endothelial cells. American Journal of Physiology-Cell Physiology. https://doi.org/10.1152/ajpcell.2001.280.6.c1475
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.