CoChat

Concurrent duodenal manometric and impedance recording to evaluate the effects of hyoscine on motility and flow events, glucose absorption, and incretin release

Chaikomin, Reawika, Wu, Keng Liang, Doran, Selena, Jones, Karen L., Smout, Andre J. P. M., Renooij, Willem, Holloway, Richard H., Meyer, James H., Horowitz, Michael, Rayner, Christopher K. · 2007 · American Journal of Physiology-Gastrointestinal and Liver Physiology
Cited by 47

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Upper gastrointestinal motor function and incretin hormone secretion are major determinants of postprandial glycemia and insulinemia. However, the impact of small intestinal flow events on glucose absorption and incretin release is poorly defined. Intraluminal impedance monitoring is a novel technique that allows flow events to be quantified. Eight healthy volunteers were studied twice, in random order. A catheter incorporating six pairs of electrodes at 3-cm intervals, and six corresponding manometry sideholes, was positioned in the duodenum. Hyoscine butylbromide (20 mg) or saline was given as an intravenous bolus, followed by a continuous intravenous infusion of either hyoscine (20 mg/h) or saline over 60 min. Concurrently, glucose and 3- O-methylglucose (3-OMG) were infused into the proximal duodenum (3 kcal/min), with frequent blood sampling to measure glucose, 3-OMG, insulin, glucagon-like peptide-1 (GLP-1) and glucose-dependent insulinotropic polypeptide (GIP). The frequency of duodenal pressure waves and propagated pressure wave sequences was reduced by hyoscine in the first 10 min ( P < 0.01 for both), but not after that time. In contrast, there were markedly fewer duodenal flow events throughout 60 min with hyoscine ( P < 0.005). Overall, blood glucose ( P < 0.01) and plasma 3-OMG concentrations ( P < 0.05) were lower during hyoscine than saline, whereas plasma insulin, GLP-1, and GIP concentrations were initially ( t = 20 min) lower during hyoscine ( P < 0.05). In conclusion, intraluminal impedance measurement may be more sensitive than manometry in demonstrating alterations in duodenal motor function. A reduction in the frequency of duodenal flow events is associated with a decreased rate of glucose absorption and incretin release in healthy subjects.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajpgi.00519.2006

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 47

Metadata

Authors
Chaikomin, R., Wu, K. L., Doran, S., Jones, K. L., Smout, A. J. P. M., Renooij, W., Holloway, R. H., Meyer, J. H., Horowitz, M., & Rayner, C. K.
Venue
American Journal of Physiology-Gastrointestinal and Liver Physiology
Published
2007-04
Volume
292
Issue
4
Pages
G1099-G1104
ISSN
  • 0193-1857 (ISSN-L)
  • 1522-1547
OpenAlex
W2105460592
Cited by
47
References
5
FWCI
3.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.