Determinants of valve gating in collecting lymphatic vessels from rat mesentery
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Secondary lymphatic valves are essential for minimizing backflow of lymph and are presumed to gate passively according to the instantaneous trans-valve pressure gradient. We hypothesized that valve gating is also modulated by vessel distention, which could alter leaflet stiffness and coaptation. To test this hypothesis, we devised protocols to measure the small pressure gradients required to open or close lymphatic valves and determine if the gradients varied as a function of vessel diameter. Lymphatic vessels were isolated from rat mesentery, cannulated, and pressurized using a servo-control system. Detection of valve leaflet position simultaneously with diameter and intraluminal pressure changes in two-valve segments revealed the detailed temporal relationships between these parameters during the lymphatic contraction cycle. The timing of valve movements was similar to that of cardiac valves, but only when lymphatic vessel afterload was elevated. The pressure gradients required to open or close a valve were determined in one-valve segments during slow, ramp-wise pressure elevation, either from the input or output side of the valve. Tests were conducted over a wide range of baseline pressures (and thus diameters) in passive vessels as well as in vessels with two levels of imposed tone. Surprisingly, the pressure gradient required for valve closure varied >20-fold (0.1–2.2 cmH 2 O) as a passive vessel progressively distended. Similarly, the pressure gradient required for valve opening varied sixfold with vessel distention. Finally, our functional evidence supports the concept that lymphatic muscle tone exerts an indirect effect on valve gating.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intrinsic contractility of prenodal lymph vessels and lymph flow in human leg
Olszewski, W. L., & Engeset, A. (1980) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1980.239.6.h775 · Cited by 201
Gasheva, O. Y., Zawieja, D. C., & Gashev, A. A. (2006) · The Journal of Physiology · doi:10.1113/jphysiol.2006.115212 · Cited by 181 · cited 1×
“We are able to simulate this condition by setting Pin higher than Pout and thereby imposing a favorable gradient for flow (23, 25).”
MethodSelf-citationMyogenic constriction and dilation of isolated lymphatic vessels
Davis, M. J., Davis, A. M., Ku, C. W., & Gashev, A. A. (2009) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01040.2008 · Cited by 78 · cited 1×
“2%) slightly exceeded the upper limit of basal tone observed under several physiological conditions (11, 13, 22, 23).”
BackgroundSelf-citation
Cited by
Wiig, H., & Swartz, M. A. (2012) · Physiological Reviews · doi:10.1152/physrev.00037.2011 · Cited by 722
Lymphatic pumping: mechanics, mechanisms and malfunction
Scallan, J. P., Zawieja, S. D., Castorena‐Gonzalez, J. A., & Davis, M. J. (2016) · The Journal of Physiology · doi:10.1113/jp272088 · Cited by 424
“Panel B modified from Davis et al. (2011).”
BackgroundMethodInfluentialSelf-citationOpportunities and challenges in the diagnostic utility of dermal interstitial fluid
Friedel, M., Thompson, I. A. P., Kasting, G., Polsky, R., Cunningham, D., Soh, H. T., & Heikenfeld, J. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00998-9 · Cited by 360
Lymphatic Vessel Network Structure and Physiology
Breslin, J. W., Yang, Y., Scallan, J. P., Sweat, R. S., Adderley, S. P., & Murfee, W. L. (2018) · Comprehensive Physiology · doi:10.1002/cphy.c180015 · Cited by 341
Moore, J. E., & Bertram, C. D. (2018) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-122316-045259 · Cited by 340
Self-citationThe lymphatic system: integral roles in immunity
Randolph, G. J., Ivanov, S., Zinselmeyer, B. H., & Scallan, J. P. (2017) · Annual Review of Immunology · doi:10.1146/annurev-immunol-041015-055354 · Cited by 338
The Lymphatic System in Disease Processes and Cancer Progression
Padera, T. P., Meijer, E. F. J., & Munn, L. L. (2016) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-112315-031200 · Cited by 248
“These valves maintain unidirectional proximal lymph flow by preventing flow distally when closed and functioning properly (25).”
BackgroundYao, L.-C., Baluk, P., Srinivasan, R. S., Oliver, G., & McDonald, D. M. (2012) · The American Journal of Pathology · doi:10.1016/j.ajpath.2012.02.019 · Cited by 203
Topical tacrolimus for the treatment of secondary lymphedema
Gardenier, J. C., Kataru, R. P., Hespe, G. E., Savetsky, I. L., Torrisi, J. S., Nores, G. D. G., Jowhar, D. K., Nitti, M. D., Schofield, R. C., Carlow, D. C., et al. (2017) · Nature Communications · doi:10.1038/ncomms14345 · Cited by 137
Intrinsic increase in lymphangion muscle contractility in response to elevated afterload
Davis, M. J., Scallan, J. P., Wolpers, J. H., Muthuchamy, M., Gashev, A. A., & Zawieja, D. C. (2012) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01097.2011 · Cited by 133
Self-citationZawieja, S. D., Castorena-Gonzalez, J. A., Scallan, J. P., & Davis, M. J. (2018) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00499.2017 · Cited by 89
Self-citationScallan, J. P., Wolpers, J. H., Muthuchamy, M., Zawieja, D. C., Gashev, A. A., & Davis, M. J. (2012) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01098.2011 · Cited by 79
Self-citationAno1 mediates pressure-sensitive contraction frequency changes in mouse lymphatic collecting vessels
Zawieja, S. D., Castorena, J. A., Gui, P., Li, M., Bulley, S. A., Jaggar, J. H., Rock, J. R., & Davis, M. J. (2019) · Journal of General Physiology · doi:10.1085/jgp.201812294 · Cited by 70
Self-citationJamalian, S., Jafarnejad, M., Zawieja, S. D., Bertram, C. D., Gashev, A. A., Zawieja, D. C., Davis, M. J., & Moore, J. E. (2017) · Scientific Reports · doi:10.1038/s41598-017-11599-x · Cited by 69
Self-citationScallan, J. P., Wolpers, J. H., & Davis, M. J. (2013) · The Journal of Physiology · doi:10.1113/jphysiol.2012.237909 · Cited by 66
“The Journal of Physiology C© 2012 The Physiological Society 20-fold with increasing vessel diameter (Davis et al. 2011).”
BackgroundMethodSelf-citationTransport and Immune Functions of the Lymphatic System.
Davis, M. J., Zawieja, S. D., & King, P. D. (2025) · Annual Review of Physiology · doi:10.1146/annurev-physiol-022724-104908 · Cited by 42
Self-citationNepiyushchikh, Z. V., Chakraborty, S., Wang, W., Davis, M. J., Zawieja, D. C., & Muthuchamy, M. (2011) · The Journal of Physiology · doi:10.1113/jphysiol.2011.218446 · Cited by 37
Self-citationMaximum shortening velocity of lymphatic muscle approaches that of striated muscle
Zhang, R., Taucer, A. I., Gashev, A. A., Muthuchamy, M., Zawieja, D. C., & Davis, M. J. (2013) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00898.2012 · Cited by 26
Self-citationDavis, M. J., Castorena-Gonzalez, J. A., Kim, H. J., Li, M., Remedi, M., & Nichols, C. G. (2023) · Function · doi:10.1093/function/zqad017 · Cited by 25
Self-citationScallan, J. P., Bouta, E. M., Rahimi, H., Kenney, H. M., Ritchlin, C. T., Davis, M. J., & Schwarz, E. M. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.745096 · Cited by 22
“) of the vessel on the video image and recorded it as a function of time (Davis et al., 2011).”
BackgroundMethodSelf-citation
Metadata
- Authors
- Davis, M. J., Rahbar, E., Gashev, A. A., Zawieja, D. C., & Moore, J. E.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2011-07
- Volume
- 301
- Issue
- 1
- Pages
- H48-H60
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2122048115
- Cited by
- 179
- References
- 3
- FWCI
- 4.27
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.