Correlation between heart valve interstitial cell stiffness and transvalvular pressure: implications for collagen biosynthesis
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
It has been speculated that heart valve interstitial cells (VICs) maintain valvular tissue homeostasis through regulated extracellular matrix (primarily collagen) biosynthesis. VICs appear to be phenotypically plastic, inasmuch as they transdifferentiate into myofibroblasts during valve development, disease, and remodeling. Under normal physiological conditions, transvalvular pressures (TVPs) on the right and left side of the heart are vastly different. Hence, we hypothesize that higher left-side TVPs impose larger local tissue stress on VICs, which increases their stiffness through cytoskeletal composition, and that this relation affects collagen biosynthesis. To evaluate this hypothesis, isolated ovine VICs from the four heart valves were subjected to micropipette aspiration to assess cellular stiffness, and cytoskeletal composition and collagen biosynthesis were quantified by using the surrogates smooth muscle α-actin (SMA) and heat shock protein 47 (HSP47), respectively. VICs from the aortic and mitral valves were significantly stiffer ( P < 0.001) than those from the pulmonary and tricuspid valves. Left-side isolated VICs contained significantly more ( P < 0.001) SMA and HSP47 than right-side VICs. Mean VIC stiffness correlated well ( r = 0.973) with TVP; SMA and HSP47 also correlated well ( r = 0.996) with one another. Assays were repeated for VICs in situ, and, as with in vitro results, left-side VIC protein levels were significantly greater ( P < 0.05). These findings suggest that VICs respond to local tissue stress by altering cellular stiffness (through SMA content) and collagen biosynthesis. This functional VIC stress-dependent biosynthetic relation may be crucial in maintaining valvular tissue homeostasis and also prove useful in understanding valvular pathologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Textbook of Medical Physiology
(1966) · Annals of Internal Medicine · doi:10.7326/0003-4819-64-6-1363_2 · Cited by 9,749
Micropipette aspiration of living cells
Hochmuth, R. M. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00175-x · Cited by 1,423 · cited 2×
“For each population, 80 l of cell-suspended medium were aspirated and placed in a chamber that allows entry of a pipette from the side (13).”
BackgroundMethodApparent viscosity and cortical tension of blood granulocytes determined by micropipet aspiration
Evans, E., & Yeung, A. (1989) · Biophysical Journal · doi:10.1016/s0006-3495(89)82660-8 · Cited by 788 · cited 1×
“Micropipette aspiration has been used to determine the mechanical response of multiple cell types (4, 6, 9, 13, 28, 30), and the experimental setup has been described previously (35).”
MethodGuilak, F., & Mow, V. C. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00105-6 · Cited by 471 · cited 9×
“In the AV, TVPs above 5 mmHg predominantly result in ECM compaction as the collagen fibers become uncrimped and taut (27).”
BackgroundInfluentialSelf-citationBilliar, K. L., & Sacks, M. S. (2000) · Journal of Biomechanical Engineering · doi:10.1115/1.429624 · Cited by 441
Self-citationPassive mechanical properties of human leukocytes
Schmid-Schönbein, G. W., Sung, K. L., Tözeren, H., Skalak, R., & Chien, S. (1981) · Biophysical Journal · doi:10.1016/s0006-3495(81)84726-1 · Cited by 417 · cited 1×
“Micropipette aspiration has been used to determine the mechanical response of multiple cell types (4, 6, 9, 13, 28, 30), and the experimental setup has been described previously (35).”
MethodTheret, D. P., Levesque, M. J., Sato, M., Nerem, R. M., & Wheeler, L. T. (1988) · Journal of Biomechanical Engineering · doi:10.1115/1.3108430 · Cited by 382 · cited 1×
“The effective stiffness (E) of the cell was determined with a half-space model, referred to as the punch model, which assumes that the cell is an isotropic, elastic, incompressible, half-space material (34).”
MethodSato, M., Theret, D. P., Wheeler, L. T., Ohshima, N., & Nerem, R. M. (1990) · Journal of Biomechanical Engineering · doi:10.1115/1.2891183 · Cited by 373 · cited 1×
“Micropipette aspiration has been used to determine the mechanical response of multiple cell types (4, 6, 9, 13, 28, 30), and the experimental setup has been described previously (35).”
MethodDynamic and reversible changes of interstitial cell phenotype during remodeling of cardiac valves.
Aikawa, E. R., Farber, M., Aikawa, M., & Schöen, F. J. (2004) · PubMed · Cited by 354
The cardiac valve interstitial cell
Taylor, P. M., Batten, P., Brand, N. J., Thomas, P. S., & Yacoub, M. H. (2003) · The International Journal of Biochemistry & Cell Biology · doi:10.1016/s1357-2725(02)00100-0 · Cited by 290 · cited 1×
“The majority of heart valve interstitial cells (VICs) within mammalian heart valve leaflets can be categorized as myofibroblasts because of their dual phenotypic characteristics of fibroblast and smooth muscle-like cells (7, 19, 21, 33).”
Background
Cited by
The Emerging Role of Valve Interstitial Cell Phenotypes in Regulating Heart Valve Pathobiology
Liu, A. C., Joag, V. R., & Gotlieb, A. I. (2007) · The American Journal of Pathology · doi:10.2353/ajpath.2007.070251 · Cited by 632
Mikos, A. G., Herring, S. W., Ochareon, P., Elisseeff, J., Lu, H. H., Kandel, R., Schoen, F. J., Toner, M., Mooney, D., Atala, A., et al. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.3307 · Cited by 598
Atala, A., Kasper, F. K., & Mikos, A. G. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3004890 · Cited by 544
Duan, B., Kapetanovic, E., Hockaday, L. A., & Butcher, J. T. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.12.005 · Cited by 436
Schoen, F. J. (2008) · Circulation · doi:10.1161/circulationaha.108.805911 · Cited by 421
Heart valve function: a biomechanical perspective
Sacks, M. S., & Yoganathan, A. P. (2007) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2007.2122 · Cited by 387
Self-citationOn the biomechanics of heart valve function
Sacks, M. S., David Merryman, W., & Schmidt, D. E. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.05.015 · Cited by 372
Self-citationYutzey, K. E., Demer, L. L., Body, S. C., Huggins, G. S., Towler, D. A., Giachelli, C. M., Hofmann-Bowman, M. A., Mortlock, D. P., Rogers, M. B., Sadeghi, M. M., et al. (2014) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvbaha.114.302523 · Cited by 371
Valve Interstitial Cells: The Key to Understanding the Pathophysiology of Heart Valve Calcification
Rutkovskiy, A., Malashicheva, A., Sullivan, G., Bogdanova, M., Kostareva, A., Stensløkken, K., Fiane, A., & Vaage, J. (2017) · Journal of the American Heart Association · doi:10.1161/jaha.117.006339 · Cited by 358
Heart Valve Tissue Engineering: Concepts, Approaches, Progress, and Challenges
Mendelson, K., & Schoen, F. J. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9163-z · Cited by 328
Serotonin receptors and heart valve disease—It was meant 2B
Hutcheson, J. D., Setola, V., Roth, B. L., & Merryman, W. D. (2011) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2011.03.008 · Cited by 252
Self-citationBalachandran, K., Sucosky, P., Jo, H., & Yoganathan, A. P. (2009) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00900.2008 · Cited by 201
“(19) reported that valve interstitial cells respond to local tissue stresses by altering cellular stiffness via collagen biosynthesis.”
Hemodynamics and Mechanobiology of Aortic Valve Inflammation and Calcification
Balachandran, K., Sucosky, P., & Yoganathan, A. P. (2011) · International Journal of Inflammation · doi:10.4061/2011/263870 · Cited by 168
“reported that valve interstitial cells respond to local tissue stresses by altering cellular stiffness via collagen biosynthesis [82].”
BackgroundYang, X., Fullerton, D. A., Su, X., Ao, L., Cleveland, J. C., & Meng, X. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.09.052 · Cited by 162
Mechanobiology of myofibroblast adhesion in fibrotic cardiac disease
Schroer, A. K., & Merryman, W. D. (2015) · Journal of Cell Science · doi:10.1242/jcs.162891 · Cited by 127
“Conditions that favor increased local tissue strains and stresses increase the risk of developing fibrotic disease in affected structures by altering the behavior and phenotype of cardiac cells, which contributes to maladaptive tissue remodeling (Cuniberti et al., 2006; Merryman et al., 2006).”
BackgroundSelf-citationRecellularization of decellularized heart valves: Progress toward the tissue-engineered heart valve
VeDepo, M. C., Detamore, M. S., Hopkins, R. A., & Converse, G. L. (2017) · Journal of Tissue Engineering · doi:10.1177/2041731417726327 · Cited by 117
Self-citationJetValve: Rapid manufacturing of biohybrid scaffolds for biomimetic heart valve replacement
Capulli, A. K., Emmert, M. Y., Pasqualini, F. S., Kehl, D., Caliskan, E., Lind, J. U., Sheehy, S. P., Park, S. J., Ahn, S., Weber, B., et al. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.04.033 · Cited by 112
Non-physiologic Bioreactor Processing Conditions for Heart Valve Tissue Engineering
VeDepo, M. C., Buse, E. E., Paul, A., Converse, G. L., & Hopkins, R. A. (2019) · Cardiovascular Engineering and Technology · doi:10.1007/s13239-019-00438-x · Cited by 10
Self-citation
Metadata
- Authors
- Merryman, W. D., Youn, I., Lukoff, H. D., Krueger, P. M., Guilak, F., Hopkins, R. A., & Sacks, M. S.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2006-01
- Volume
- 290
- Issue
- 1
- Pages
- H224-H231
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2148318841
- Cited by
- 225
- References
- 29
- FWCI
- 6.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.