The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Mathematical model of oxygen distribution in engineered cardiac tissue with parallel channel array perfused with culture medium containing oxygen carriers
Abstract
A steady-state model of oxygen distribution in a cardiac tissue construct with a parallel channel array was developed and solved for a set of parameters using the finite element method and commercial software (FEMLAB). The effects of an oxygen carrier [Oxygent; 32% volume perfluorocarbon (PFC) emulsion] were evaluated. The parallel channel array mimics the in vivo capillary tissue bed, and the PFC emulsion has a similar role as the natural oxygen carrier hemoglobin in increasing total oxygen content. The construct was divided into an array of cylindrical domains with a channel in the center and tissue space surrounding the channel. In the channel, the main modes of mass transfer were axial convection and radial diffusion. In the tissue region, mass transfer was by axial and radial diffusion, and the consumption of oxygen was by Michaelis-Menten kinetics. Neumann boundary conditions were imposed at the channel centerline and the half distance between the domains. Supplementation of culture medium by PFC emulsion improved mass transport by increasing convective term and effective diffusivity of culture medium. The model was first implemented for the following set of experimentally obtained parameters: construct thickness of 0.2 cm, channel diameter of 330 μm, channel center-to-center spacingof 700 μm, and average linear velocity per channel of 0.049 cm/s, in conjunction with PFC supplemented and unsupplemented culture medium. Subsequently, the model was used to define favorable scaffold geometry and flow conditions necessary to cultivate cardiac constructs of high cell density (10 8 cells/ml) and clinically relevant thickness (0.5 cm). In future work, the model can be utilized as a tool for optimization of scaffold geometry and flow conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transport Processes and Unit Operations
(1994) · Chemical Engineering Science · doi:10.1016/0009-2509(94)85079-8 · Cited by 1,563
A tough biodegradable elastomer
Wang, Y., Ameer, G. A., Sheppard, B. J., & Langer, R. (2002) · Nature Biotechnology · doi:10.1038/nbt0602-602 · Cited by 1,314 · cited 1×
“Porous poly(glycerolsebacate) scaffolds were fabricated by means of a salt-leaching technique, as previously described (32).”
MethodSelf-citationAnalysis of transport phenomena
Deen, W. M. (1998) · Cited by 1,237
Self-citationBancroft, G. N., Sikavitsas, V. I., van den Dolder, J., Sheffield, T. L., Ambrose, C. G., Jansen, J. A., & Mikos, A. G. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.202296599 · Cited by 693
Carrier, R. L., Papadaki, M., Rupnick, M., Schoen, F. J., Bursac, N., Langer, R., Freed, L. E., & Vunjak-Novakovic, G. (1999) · Biotechnology and Bioengineering · doi:10.1002/(sici)1097-0290(19990905)64:5<580::aid-bit8>3.0.co;2-x · Cited by 540
Self-citationSikavitsas, V. I., Bancroft, G. N., Holtorf, H. L., Jansen, J. A., & Mikos, A. G. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2434367100 · Cited by 472
Effects of Medium Perfusion Rate on Cell-Seeded Three-Dimensional Bone Constructs in Vitro
Cartmell, S. H., Porter, B. D., García, A. J., & Guldberg, R. E. (2003) · Tissue Engineering · doi:10.1089/10763270360728107 · Cited by 387
Cardiac muscle tissue engineering: toward an in vitro model for electrophysiological studies
Bursac, N., Papadaki, M., Cohen, R. J., Schoen, F. J., Eisenberg, S. R., Carrier, R., Vunjak-Novakovic, G., & Freed, L. E. (1999) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1999.277.2.h433 · Cited by 366
Self-citationMedium perfusion enables engineering of compact and contractile cardiac tissue
Radisic, M., Yang, L., Boublik, J., Cohen, R. J., Langer, R., Freed, L. E., & Vunjak-Novakovic, G. (2004) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00171.2003 · Cited by 332
Self-citationPerfusion Improves Tissue Architecture of Engineered Cardiac Muscle
Carrier, R. L., Rupnick, M., Langer, R., Schoen, F. J., Freed, L. E., & Vunjak-Novakovic, G. (2002) · Tissue Engineering · doi:10.1089/107632702753724950 · Cited by 323
Self-citationHigh‐density seeding of myocyte cells for cardiac tissue engineering
Radisic, M., Euloth, M., Yang, L., Langer, R., Freed, L. E., & Vunjak‐Novakovic, G. (2003) · Biotechnology and Bioengineering · doi:10.1002/bit.10594 · Cited by 288
Self-citationComparison of Chondrogensis in Static and Perfused Bioreactor Culture
Pazzano, D., Mercier, K. A., Moran, J. M., Fong, S. S., DiBiasio, D. D., Rulfs, J. X., Kohles, S. S., & Bonassar, L. J. (2000) · Biotechnology Progress · doi:10.1021/bp000082v · Cited by 266
Perfusion Increases Cell Content and Matrix Synthesis in Chondrocyte Three-Dimensional Cultures
Davisson, T., Sah, R. L., & Ratcliffe, A. (2002) · Tissue Engineering · doi:10.1089/10763270260424169 · Cited by 213
The leukocyte response to fluid stress
Moazzam, F., DeLano, F. A., Zweifach, B. W., & Schmid-Schönbein, G. W. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.10.5338 · Cited by 209
Shear stress effects on human embryonic kidney cells in Vitro
Stathopoulos, N. A., & Hellums, J. D. (1985) · Biotechnology and Bioengineering · doi:10.1002/bit.260270713 · Cited by 169
Effects of oxygen on engineered cardiac muscle
Carrier, R. L., Rupnick, M. A., Langer, R., Schöen, F. J., Freed, L. E., & Vunjak‐Novakovic, G. (2002) · Biotechnology and Bioengineering · doi:10.1002/bit.10245 · Cited by 141
Self-citationModel of oxygen transport limitations in hollow fiber bioreactors
Piret, J. M., & Cooney, C. L. (1991) · Biotechnology and Bioengineering · doi:10.1002/bit.260370112 · Cited by 114
Mechanisms for Regulation of Fluid Shear Stress Response in Circulating Leukocytes
Fukuda, S., Yasu, T., Predescu, D. N., & Schmid‐Schönbein, G. W. (2000) · Circulation Research · doi:10.1161/01.res.86.1.e13 · Cited by 102
Chromiak, J., Shansky, J., Perrone, C. E., & Vandenburgh, H. (1998) · In vitro Cellular & Developmental Biology-Animal · doi:10.1007/s11626-998-0065-2 · Cited by 76
Functional capillary density in normal and transplanted rat hearts
KORECKY, B., Hai, C. M., & Rakusan, K. (1982) · Canadian Journal of Physiology and Pharmacology · doi:10.1139/y82-003 · Cited by 67
Hibernation in Noncontracting Mammalian Cardiomyocytes
Casey, T. M., & Arthur, P. G. (2000) · Circulation · doi:10.1161/01.cir.102.25.3124 · Cited by 50
Yamada, T., Yang, J. J., Ricchiuti, N. V., & Seraydarian, M. W. (1985) · Analytical Biochemistry · doi:10.1016/0003-2697(85)90365-3 · Cited by 38
The effect of growth and aging on functional capillary supply of the rat heart.
Rakusan, K., & KORECKY, B. (1982) · PubMed · Cited by 37
Hyaluronate‐alginate gel as a novel biomaterial: Mechanical properties and formation mechanism
Oerther, S., Gall, H. L., Payan, E., Lapicque, F., Presle, N., Hubert, P., Dexheimer, J., Netter, P., & Lapicque, F. (1999) · Biotechnology and Bioengineering · doi:10.1002/(sici)1097-0290(19990420)63:2<197::aid-bit8>3.0.co;2-2 · Cited by 2
Cited by
Bhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
Perfusion-decellularized matrix: using nature's platform to engineer a bioartificial heart
Ott, H. C., Matthiesen, T. S., Goh, S.-K., Black, L. D., Kren, S. M., Netoff, T. I., & Taylor, D. A. (2008) · Nature Medicine · doi:10.1038/nm1684 · Cited by 2,650
“The creation of 'thick' (>100–200 μm) cardiac patches has been limited by an inability to create the geometry necessary to support the high oxygen and energy demands of cardiomyocytes at a depth greater than ∼100 μm from the surfac”
BackgroundBioprinting 3D microfibrous scaffolds for engineering endothelialized myocardium and heart-on-a-chip
Zhang, Y. S., Arneri, A., Bersini, S., Shin, S.-R., Zhu, K., Goli-Malekabadi, Z., Aleman, J., Colosi, C., Busignani, F., Dell'Erba, V., et al. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.09.003 · Cited by 951
Vascularization Strategies for Tissue Engineering
Lovett, M., Lee, K., Edwards, A., & Kaplan, D. L. (2009) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2009.0085 · Cited by 923
Proangiogenic scaffolds as functional templates for cardiac tissue engineering
Madden, L. R., Mortisen, D. J., Sussman, E. M., Dupras, S. K., Fugate, J. A., Cuy, J. L., Hauch, K. D., Laflamme, M. A., Murry, C. E., & Ratner, B. D. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1006442107 · Cited by 662
Metadata
- Authors
- Radisic, M., Deen, W., Langer, R., & Vunjak-Novakovic, G.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2005-03
- Volume
- 288
- Issue
- 3
- Pages
- H1278-H1289
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2113738161
- Cited by
- 269
- References
- 24
- FWCI
- 9.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.