Impact of anesthesia on cardiac function during echocardiography in mice
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Anesthetics provide sedation and immobility facilitating echocardiography in mice, but influence cardiac function. We studied the effects of intraperitoneal and inhaled anesthetic agents on echocardiographic measurements. Mice were anesthetized with intraperitoneal tribromoethanol (TBE), ketamine-midazolam (K/M), ketamine-xylazine (K/X), or inhaled isoflurane (Isf), and echocardiographic parameters were assessed at 5, 10, 15, and 20 min. In C57BL/6N mice, Isf produced high initial heart rates (HR) that decreased to levels comparable to TBE at 15–20 min (∼450 beats/min) and the most stable percent fractional shortening (%FS) and end-diastolic dimension (EDD). With TBE, %FS initially was low, but increased comparable to Isf (∼45%) at 15 min. K/M produced similar time trends but lower absolute values compared with TBE for all parameters. K/X produced cardiac depression evidenced by low HR and %FS, and increased EDD. Isf was the most reproducible in repeat studies at 12 days. In C57BL/6J compared with C57BL/6N mice, K/M produced higher HR, and %FS and TBE produced smaller EDD. In conclusion, anesthetic agent, timing of echocardiographic measurements, and genetic background are all critical variables during echocardiography in mice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistical principles in experimental design.
Winer, B. J. (1962) · McGraw-Hill Book Company · doi:10.1037/11774-000 · Cited by 26,755
Some statistical methods useful in circulation research.
Wallenstein, S., Zucker, C. L., & Fleiss, J. L. (1980) · Circulation Research · doi:10.1161/01.res.47.1.1 · Cited by 3,886
Minamisawa, S., Hoshijima, M., Chu, G., Ward, C. A., Frank, K., Gu, Y., Martone, M. E., Wang, Y., Ross, J., Kranias, E. G., et al. (1999) · Cell · doi:10.1016/s0092-8674(00)81662-1 · Cited by 506
Self-citationCardiovascular Control Mechanisms in the Conscious State
Vatner, S. F., & Braunwald, E. (1975) · New England Journal of Medicine · doi:10.1056/nejm197511062931906 · Cited by 390
Echocardiographic assessment of cardiac function in conscious and anesthetized mice
Yang, X.-P., Liu, Y.-H., Rhaleb, N.-E., Kurihara, N., Kim, H. E., & Carretero, O. A. (1999) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1999.277.5.h1967 · Cited by 365
Transthoracic Echocardiography in Models of Cardiac Disease in the Mouse
Tanaka, N., Dalton, N., Mao, L., Rockman, H. A., Peterson, K. L., Gottshall, K. R., Hunter, J. J., Chien, K. R., & Ross, J. (1996) · Circulation · doi:10.1161/01.cir.94.5.1109 · Cited by 364
Self-citationFentzke, R. C., Korcarz, C. E., Lang, R. M., Lin, H., & Leiden, J. M. (1998) · Journal of Clinical Investigation · doi:10.1172/jci2950 · Cited by 246
Takeishi, Y., Ping, P., Bolli, R., Kirkpatrick, D. L., Hoit, B. D., & Walsh, R. A. (2000) · Circulation Research · doi:10.1161/01.res.86.12.1218 · Cited by 239
Efficacy of tribromoethanol anesthesia in mice.
Papaioannou, V. E., & Fox, J. G. (1993) · PubMed · Cited by 201
Cardiac-Directed Adenylyl Cyclase Expression Improves Heart Function in Murine Cardiomyopathy
Roth, D. M., Gao, M. H., Lai, N. C., Drumm, J., Dalton, N., Zhou, J. Y., Zhu, J., Entrikin, D., & Hammond, H. K. (1999) · Circulation · doi:10.1161/01.cir.99.24.3099 · Cited by 176
Self-citation
Cited by
Genetic Differences among C57BL/6 Substrains
MEKADA, K., ABE, K., MURAKAMI, A., NAKAMURA, S., NAKATA, H., MORIWAKI, K., OBATA, Y., & YOSHIKI, A. (2009) · Experimental Animals · doi:10.1538/expanim.58.141 · Cited by 358
Guidelines for measuring cardiac physiology in mice
Lindsey, M. L., Kassiri, Z., Virag, J. A. I., de Castro Brás, L. E., & Scherrer-Crosbie, M. (2018) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00339.2017 · Cited by 349
Altered blood pressure responses and normal cardiac phenotype in ACE2-null mice
Gurley, S. B., Allred, A., Le, T. H., Griffiths, R., Mao, L., Philip, N., Haystead, T. A., Donoghue, M., Breitbart, R. E., Acton, S. L., et al. (2006) · Journal of Clinical Investigation · doi:10.1172/jci16980 · Cited by 334
Effects of anesthetics on systemic hemodynamics in mice
Janssen, B. J. A., De Celle, T., Debets, J. J. M., Brouns, A. E., Callahan, M. F., & Smith, T. L. (2004) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01192.2003 · Cited by 318
Gao, S., Ho, D., Vatner, D. E., & Vatner, S. F. (2011) · Current Protocols in Mouse Biology · doi:10.1002/9780470942390.mo100130 · Cited by 273
LIAO, Y., TAKASHIMA, S., MAEDA, N., OUCHI, N., KOMAMURA, K., SHIMOMURA, I., HORI, M., MATSUZAWA, Y., FUNAHASHI, T., & KITAKAZE, M. (2005) · Cardiovascular Research · doi:10.1016/j.cardiores.2005.04.018 · Cited by 236
“Because anesthesia has a significant influence on echocardiography data in mice [25] and most of the KO TAC mice were too weak for anesthesia at 3 weeks after TAC, we developed a method of performing echocardiographic examination in conscious mice.”
MethodEchocardiographic evaluation of diastolic function in mouse models of heart disease
Schnelle, M., Catibog, N., Zhang, M., Nabeebaccus, A. A., Anderson, G., Richards, D. A., Sawyer, G., Zhang, X., Toischer, K., Hasenfuss, G., et al. (2018) · Journal of Molecular and Cellular Cardiology · doi:10.1016/j.yjmcc.2017.10.006 · Cited by 169
“A consistent measurement of E/A ratio in the mouse heart is probably only feasible if heart rate is artificially reduced, for example with deeper anesthesia, but this is undesirable due to the likelihood of associated cardiac depression.[28] Therefore, the routine assessment of these parameters is unlikely to be usefu…”
BackgroundHadi, T., Boytard, L., Silvestro, M., Alebrahim, D., Jacob, S., Feinstein, J., Barone, K., Spiro, W., Hutchison, S., Simon, R., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-07495-1 · Cited by 168
Development of dilated cardiomyopathy in Bmal1-deficient mice
Lefta, M., Campbell, K. S., Feng, H.-Z., Jin, J.-P., & Esser, K. A. (2012) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00238.2012 · Cited by 158
New approaches in small animal echocardiography: imaging the sounds of silence
Ram, R., Mickelsen, D. M., Theodoropoulos, C., & Blaxall, B. C. (2011) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00559.2011 · Cited by 142
Diabetic cardiomyopathy: recent evidence from mouse models of type 1 and type 2 diabetes
Severson, D. L. (2004) · Canadian Journal of Physiology and Pharmacology · doi:10.1139/y04-065 · Cited by 111
Metadata
- Authors
- Roth, D. M., Swaney, J. S., Dalton, N. D., Gilpin, E. A., & Ross, J.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2002-06-01
- Volume
- 282
- Issue
- 6
- Pages
- H2134-H2140
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W1971972136
- Cited by
- 346
- References
- 22
- FWCI
- 27.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.