Alterations in wall shear stress predict sites of neointimal hyperplasia after stent implantation in rabbit iliac arteries
The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
Restenosis resulting from neointimal hyperplasia (NH) limits the effectiveness of intravascular stents. Rates of restenosis vary with stent geometry, but whether stents affect spatial and temporal distributions of wall shear stress (WSS) in vivo is unknown. We tested the hypothesis that alterations in spatial WSS after stent implantation predict sites of NH in rabbit iliac arteries. Antegrade iliac artery stent implantation was performed under angiography, and blood flow was measured before casting 14 or 21 days after implantation. Iliac artery blood flow domains were obtained from three-dimensional microfocal X-ray computed tomography imaging and reconstruction of the arterial casts. Indexes of WSS were determined using three-dimensional computational fluid dynamics. Vascular histology was unchanged proximal and distal to the stent. Time-dependent NH was localized within the stented region and was greatest in regions exposed to low WSS and acute elevations in spatial WSS gradients. The lowest values of WSS spatially localized to the stented area of a theoretical artery progressively increased after 14 and 21 days as NH occurred within these regions. This NH abolished spatial disparity in distributions of WSS. The results suggest that stents may introduce spatial alterations in WSS that modulate NH in vivo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Feldkamp, L. A., Davis, L. C., & Kress, J. W. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000612 · Cited by 6,319 · cited 1×
“Geometrically accurate reconstruction volumes were generated using the Feldcamp cone-beam reconstruction algorithm (7).”
MethodFischman, D. L., Leon, M. B., Baim, D. S., Schatz, R. A., Savage, M. P., Penn, I., Detre, K., Veltri, L., Ricci, D., Nobuyoshi, M., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310802 · Cited by 4,271 · cited 2×
“The rigid framework of the stent causes differences in compliance between the stented and native regions of the artery, but this stent rigidity provides structural scaffolding that is associated with reduced restenosis rates compared with angioplasty alone (4, 8).”
BackgroundMorice, M.-C., Serruys, P. W., Sousa, J. E., Fajadet, J., Ban Hayashi, E., Perin, M., Colombo, A., Schuler, G., Barragan, P., Guagliumi, G., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012843 · Cited by 4,033
Ku, D. N., Giddens, D. P., Zarins, C. K., & Glagov, S. (1985) · Arteriosclerosis: An Official Journal of the American Heart Association, Inc. · doi:10.1161/01.atv.5.3.293 · Cited by 2,707 · cited 1×
“Previous studies have suggested that there may be a correlation between stent-induced alterations in WSS and neointimal hyperplasia during pathological processes including primary atherogenesis and restenosis after angioplasty (17, 18, 20, 21, 30).”
BackgroundMcDonald's blood flow in arteries; theoretical, experimental and clinical principles
(1992) · General Pharmacology: The Vascular System · doi:10.1016/0306-3623(92)90079-y · Cited by 2,388
Introduction to fluid mechanics
(2013) · Engineering Science · doi:10.4324/9780203114964-25 · Cited by 1,957
Ku, D. N. (1997) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.29.1.399 · Cited by 1,477
Pathology of Acute and Chronic Coronary Stenting in Humans
Farb, A., Sangiorgi, G., Carter, A. J., Walley, V. M., Edwards, W. D., Schwartz, R. S., & Virmani, R. (1999) · Circulation · doi:10.1161/01.cir.99.1.44 · Cited by 871 · cited 1×
“stent implantation is located in regions where the stent lies in apposition to the intima (5, 6), suggesting that the present histological results from normal rabbit iliac arteries also differ from human lesions, which are typically eccentric in shape and place the stent in only partial contact with the calcified athe…”
BackgroundKornowski, R., Hong, M. K., Tio, F. O., Bramwell, O., Wu, H., & Leon, M. B. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00450-6 · Cited by 844
Inflammation and Restenosis in the Stent Era
Welt, F. G. P., & Rogers, C. (2002) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.0000037100.44766.5b · Cited by 628
Morphological Predictors of Restenosis After Coronary Stenting in Humans
Farb, A., Weber, D. K., Kolodgie, F. D., Burke, A. P., & Virmani, R. (2002) · Circulation · doi:10.1161/01.cir.0000019071.72887.bd · Cited by 593
Endovascular Stent Design Dictates Experimental Restenosis and Thrombosis
Rogers, C., & Edelman, E. R. (1995) · Circulation · doi:10.1161/01.cir.91.12.2995 · Cited by 543 · cited 2×
“Rabbits received antibiotic prophylaxis (5 mg/kg enrofloxacin) for 4 days after stent implantation and aspirin in their drinking water (20 mg/day) for the duration of the experimental protocol (43).”
MethodGallo, R., Padurean, A., Jayaraman, T., Marx, S., Roque, M., Adelman, S., Chesebro, J., Fallon, J., Fuster, V., Marks, A., et al. (1999) · Circulation · doi:10.1161/01.cir.99.16.2164 · Cited by 490
MOOREJR, J., XU, C., GLAGOV, S., ZARINS, C., & KU, D. (1994) · Atherosclerosis · doi:10.1016/0021-9150(94)90207-0 · Cited by 425
Grewe, P. H., Deneke, T., Machraoui, A., Barmeyer, J., & Müller, K.-M. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00486-6 · Cited by 401
Robb, R. A., Hanson, D. P., Karwoski, R. A., Larson, A. G., Workman, E. L., & Stacy, M. C. (1989) · Computerized Medical Imaging and Graphics · doi:10.1016/0895-6111(89)90285-1 · Cited by 315 · cited 1×
“Reconstructed vascular volumes were rendered using commercially available software (42) (Analyze 5.”
MethodDrug eluting stents: are human and animal studies comparable?
Virmani, R., Kolodgie, F. D., Farb, A., & Lafont, A. (2003) · Heart · doi:10.1136/heart.89.2.133 · Cited by 300 · cited 2×
“Reendothelialization of a stented artery in an experimental animal occurs between 21 and 56 days after deployment, but this process may not begin for several months in humans (37, 48).”
BackgroundFactors Influencing Blood Flow Patterns in the Human Right Coronary Artery
Myers, J. G., Moore, J. A., Ojha, M., Johnston, K. W., & Ethier, C. R. (2001) · Annals of Biomedical Engineering · doi:10.1114/1.1349703 · Cited by 240 · cited 1×
“The stent was removed, and small branches were removed using a deformable 300-grit sanding pad (33), revealing the flow domain in the distal descending aorta and iliac arteries (Fig.”
MethodRogers, C., Edelman, E. R., & Simon, D. I. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.17.10134 · Cited by 239 · cited 2×
“The mechanisms of restenosis are incompletely understood, but direct endothelial and smooth muscle cell damage, reduced compliance, and alterations in the distributions of wall shear stress (WSS) within the stented region have been implicated as potential triggering events that stimulate neointimal hyperplasia (11, 19…”
BackgroundMethodLaDisa, J. F., Guler, I., Olson, L. E., Hettrick, D. A., Kersten, J. R., Warltier, D. C., & Pagel, P. S. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1588654 · Cited by 213 · cited 4×
“by the CFD-ACE software package using the second invariant of the rate of deformation tensor as discussed previously (18) and shown below”
BackgroundMethodResultInfluentialSelf-citationAkt signaling in skeletal muscle: regulation by exercise and passive stretch
Sakamoto, K., Aschenbach, W. G., Hirshman, M. F., & Goodyear, L. J. (2003) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00228.2003 · Cited by 208
LaDisa, J. F., Olson, L. E., Guler, I., Hettrick, D. A., Audi, S. H., Kersten, J. R., Warltier, D. C., & Pagel, P. S. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01329.2003 · Cited by 179
Self-citationMechanisms of angioplasty and stent restenosis: implications for design of rational therapy
Bennett, M. R., & O'Sullivan, M. (2001) · Pharmacology & Therapeutics · doi:10.1016/s0163-7258(01)00153-x · Cited by 175 · cited 3×
“Studies in animal models have shown that neointimal hyperplasia is composed primarily of migrating and proliferating smooth muscle cells with some extracellular matrix (1).”
BackgroundMethodLihn, A. S., Richelsen, B., Pedersen, S. B., Haugaard, S. B., Rathje, G. S., Madsbad, S., & Andersen, O. (2003) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00206.2003 · Cited by 173
Requirements for Mesh Resolution in 3D Computational Hemodynamics
Prakash, S., & Ethier, C. R. (2000) · Journal of Biomechanical Engineering · doi:10.1115/1.1351807 · Cited by 172 · cited 1×
“Guidelines establishing adequate computational mesh densities required to obtain WSS determinations have been previously validated (38) and were followed in the current investigation.”
MethodAnimal Models for Atherosclerosis, Restenosis, and Endovascular Graft Research
Narayanaswamy, M., Wright, K. C., & Kandarpa, K. (2000) · Journal of Vascular and Interventional Radiology · doi:10.1016/s1051-0443(07)61271-8 · Cited by 154 · cited 1×
“Thus the rabbit iliac artery model used in the current investigation is considered to be appropriate for examining vascular responses to stent deployment (1, 34, 37).”
MethodThe comparative pathobiology of atherosclerosis and restenosis
Orford, J. L., Selwyn, A. P., Ganz, P., Popma, J. J., & Rogers, C. (2000) · The American Journal of Cardiology · doi:10.1016/s0002-9149(00)01094-8 · Cited by 149 · cited 2×
“Reendothelialization of a stented artery in an experimental animal occurs between 21 and 56 days after deployment, but this process may not begin for several months in humans (37, 48).”
BackgroundMethodCoronary restenosis: a review of mechanisms and management
Rajagopal, V., & Rockson, S. G. (2003) · The American Journal of Medicine · doi:10.1016/s0002-9343(03)00477-7 · Cited by 139 · cited 1×
“RESTENOSIS after stent implantation remains a persistent clinical problem (1, 6, 8, 28, 40, 45).”
BackgroundLaDisa, J. F., Olson, L. E., Guler, I., Hettrick, D. A., Kersten, J. R., Warltier, D. C., & Pagel, P. S. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00872.2004 · Cited by 135 · cited 1×
“We have previously shown that a steady-state inlet boundary condition corresponding to mean blood flow velocity reasonably approximated the average distributions of WSS in a stented artery (22).”
BackgroundSelf-citationHemodynamics and Wall Mechanics of a Compliance Matching Stent: In Vitro and In Vivo Analysis
Berry, J. L., Manoach, E., Mekkaoui, C., Rolland, P. H., Moore, J. E., & Rachev, A. (2002) · Journal of Vascular and Interventional Radiology · doi:10.1016/s1051-0443(07)60015-3 · Cited by 130 · cited 1×
“Novel stent designs that reduce compliance mismatch at the proximal and distal edges of the stent have also been developed (2).”
BackgroundRogers, C. (1998) · Medical Entomology and Zoology · Cited by 129
Danenberg, H. D., Welt, F. G. P., Walker, M. A., Seifert, P. A., Toegel, G. S., & Edelman, E. R. (2002) · Circulation · doi:10.1161/01.cir.0000018168.15904.bb · Cited by 120
Computational Blood Flow Modeling Based on In Vivo Measurements
Moore, J. A., Rutt, B. K., Karlik, S. J., Yin, K., & Ethier, C. R. (1999) · Annals of Biomedical Engineering · doi:10.1114/1.221 · Cited by 77 · cited 1×
“A 50:50 flow split was assumed for all computational arteries (29) and was confirmed from in vivo blood flow measurements (data not shown).”
BackgroundLaDisa, J. F., Hettrick, D. A., Olson, L. E., Guler, I., Gross, E. R., Kress, T. T., Kersten, J. R., Warltier, D. C., & Pagel, P. S. (2002) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00544.2002 · Cited by 66 · cited 2×
“Representative blood flow waveforms in the descending aorta and proximal iliac arteries during a single cardiac cycle were then constructed using a previously designed Matlab program to spatially align, segment, and ensemble average the collected data (19).”
BackgroundMethodSelf-citationNumerical Simulation of Oxygen Mass Transfer in a Compliant Curved Tube Model of a Coronary Artery
Qiu, Y., & Tarbell, J. M. (2000) · Annals of Biomedical Engineering · doi:10.1114/1.251 · Cited by 66 · cited 1×
“Neointimal hyperplasia is most prevalent in regions where the native blood flow environment is disturbed as these regions are susceptible to altered mass transport of oxygen, lowdensity lipoproteins, and cytokines traveling in the blood (39).”
BackgroundMagnetic resonance image processing and structured grid generation of a human abdominal bifurcation
Long, Q., Xu, X. Y., Collins, M. W., Bourne, M. W., & Griffith, T. M. (1998) · Computer Methods and Programs in Biomedicine · doi:10.1016/s0169-2607(98)00008-x · Cited by 61 · cited 1×
“Circumferential and axial smoothing was performed according to previously described methods (27).”
MethodMicrofocal X-ray CT imaging and pulmonary arterial distensibility in excised rat lungs
Karau, K. L., Johnson, R. H., Molthen, R. C., Dhyani, A. H., Haworth, S. T., Hanger, C. C., Roerig, D. L., & DAWSON, C. A. (2001) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2001.281.3.h1447 · Cited by 56 · cited 3×
“Data acquisition, preprocessing, and reconstruction were implemented as previously described (13, 14).”
MethodSelf-citationPulmonary arterial morphometry from microfocal X-ray computed tomography
Karau, K. L., Molthen, R. C., Dhyani, A. H., Haworth, S. T., Hanger, C. C., Roerig, D. L., Johnson, R. H., & DAWSON, C. A. (2001) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2001.281.6.h2747 · Cited by 53 · cited 3×
“Data acquisition, preprocessing, and reconstruction were implemented as previously described (13, 14).”
MethodSelf-citationClinical and angiographic predictors of restenosis following renal artery stenting.
Shammas, N. W., Kapalis, M. J., Dippel, E. J., Jerin, M. J., Lemke, J. H., Patel, P. J., & Harris, M. (2004) · PubMed · Cited by 49
Liu, S. Q., Tang, D., Tieché, C., & Alkema, P. K. (2003) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01009.2002 · Cited by 28 · cited 1×
“In contrast, these findings were absent in areas of elevated shear stress along the cylinder and after pharmacological inhibition of cellular proliferation (24, 25).”
BackgroundLiu, S. Q., Tieché, C., Tang, D., & Alkema, P. K. (2003) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00434.2003 · Cited by 21
Cited by
Computational fluid dynamics modelling in cardiovascular medicine
Morris, P. D., Narracott, A., von Tengg-Kobligk, H., Silva Soto, D. A., Hsiao, S., Lungu, A., Evans, P., Bressloff, N. W., Lawford, P. V., Hose, D. R., et al. (2016) · Heart · doi:10.1136/heartjnl-2015-308044 · Cited by 495
Patient-Specific Modeling of Cardiovascular Mechanics
Taylor, C. A., & Figueroa, C. A. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160521 · Cited by 451
Role of Endothelial Shear Stress in Stent Restenosis and Thrombosis
Koskinas, K. C., Chatzizisis, Y. S., Antoniadis, A. P., & Giannoglou, G. D. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.10.903 · Cited by 347
Bioresorbable Electronic Stent Integrated with Therapeutic Nanoparticles for Endovascular Diseases
Son, D., Lee, J., Lee, D. J., Ghaffari, R., Yun, S., Kim, S. J., Lee, J. E., Cho, H. R., Yoon, S., Yang, S., et al. (2015) · ACS Nano · doi:10.1021/acsnano.5b00651 · Cited by 239
Assessment of vascular wall shear stress and implications for atherosclerotic disease
Papaioannou, T. G., Karatzis, E. N., Vavuranakis, M., Lekakis, J. P., & Stefanadis, C. (2006) · International Journal of Cardiology · doi:10.1016/j.ijcard.2006.03.035 · Cited by 126
Metadata
- Authors
- LaDisa, J. F., Olson, L. E., Molthen, R. C., Hettrick, D. A., Pratt, P. F., Hardel, M. D., Kersten, J. R., Warltier, D. C., & Pagel, P. S.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2005-05
- Volume
- 288
- Issue
- 5
- Pages
- H2465-H2475
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2041119324
- Cited by
- 185
- References
- 41
- FWCI
- 6.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.