The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Tissue-engineered microvessels on three-dimensional biodegradable scaffolds using human endothelial progenitor cells
Abstract
Tissue engineering may offer patients new options when replacement or repair of an organ is needed. However, most tissues will require a microvascular network to supply oxygen and nutrients. One strategy for creating a microvascular network would be promotion of vasculogenesis in situ by seeding vascular progenitor cells within the biopolymeric construct. To pursue this strategy, we isolated CD34(+)/CD133(+) endothelial progenitor cells (EPC) from human umbilical cord blood and expanded the cells ex vivo as EPC-derived endothelial cells (EC). The EPC lost expression of the stem cell marker CD133 but continued to express the endothelial markers KDR/VEGF-R2, VE-cadherin, CD31, von Willebrand factor, and E-selectin. The cells were also shown to mediate calcium-dependent adhesion of HL-60 cells, a human promyelocytic leukemia cell line, providing evidence for a proinflammatory endothelial phenotype. The EPC-derived EC maintained this endothelial phenotype when expanded in roller bottles and subsequently seeded on polyglycolic acid-poly-l-lactic acid (PGA-PLLA) scaffolds, but microvessel formation was not observed. In contrast, EPC-derived EC seeded with human smooth muscle cells formed capillary-like structures throughout the scaffold (76.5 +/- 35 microvessels/mm(2)). These results indicate that 1) EPC-derived EC can be expanded in vitro and seeded on biodegradable scaffolds with preservation of endothelial phenotype and 2) EPC-derived EC seeded with human smooth muscle cells form microvessels on porous PGA-PLLA scaffolds. These properties indicate that EPC may be well suited for creating microvascular networks within tissue-engineered constructs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomaterial–microvasculature interactions
Sieminski, A. L., & Gooch, K. J. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00149-6 · Cited by 155
Cited by
Tumour stem cells and drug resistance
Dean, M., Fojo, T., & Bates, S. (2005) · Nature reviews. Cancer · doi:10.1038/nrc1590 · Cited by 3,668
In vivo vasculogenic potential of human blood-derived endothelial progenitor cells
Melero-Martin, J. M., Khan, Z. A., Picard, A., Wu, X., Paruchuri, S., & Bischoff, J. (2007) · Blood · doi:10.1182/blood-2006-12-062471 · Cited by 501
Self-citationMelero-Martin, J. M., De Obaldia, M. E., Kang, S.-Y., Khan, Z. A., Yuan, L., Oettgen, P., & Bischoff, J. (2008) · Circulation Research · doi:10.1161/circresaha.108.178590 · Cited by 488
Self-citationSantos, M. I., & Reis, R. L. (2010) · Macromolecular Bioscience · doi:10.1002/mabi.200900107 · Cited by 443
Cellular and Molecular Dynamics in the Foreign Body Reaction
Luttikhuizen, D. T., Harmsen, M. C., & Luyn, M. J. A. V. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.1955 · Cited by 396
Metadata
- Authors
- Wu, X., Rabkin-Aikawa, E., Guleserian, K. J., Perry, T. E., Masuda, Y., Sutherland, F. W. H., Schoen, F. J., Mayer, J. E., & Bischoff, J.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2004-08
- Volume
- 287
- Issue
- 2
- Pages
- H480-H487
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W1974895114
- Cited by
- 231
- References
- 1
- FWCI
- 19.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.