Generalization of the Fahraeus principle for microvessel networks
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Microvessel hematocrits and diameters were determined in each vessel segment between bifurcations of three complete microvascular networks in rat mesentery. Classification of the segments as arteriolar, venular, or arteriovenular (av) was based on flow direction at branch points. Photographic and videomicroscopic mapping was used to obtain quantitative information on the architecture and topology of the networks. This topological information allowed the analysis of hematocrit distribution within a series of consecutive-flow cross sections, each of which carried the total flow through the network. The observed reduction of mean hematocrit in the more peripheral cross sections is explained by the presence of a “vessel” and a “network” Fahraeus effect. The vessel Fahraeus effect results from velocity difference between red cells and blood within the individual vessel segments due to the existing velocity and cell concentration profiles. The network Fahraeus effect is based on the velocity difference of red cells and blood caused by velocity and hematocrit heterogeneity between the vessels constituting any of the complete-flow cross sections. The network Fahraeus effect is found to account for approximately 20% of the total hematocrit reduction and increases toward the most distal cross sections.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
HORTON, R. E. (1945) · Geological Society of America Bulletin · doi:10.1130/0016-7606(1945)56[275:edosat]2.0.co;2 · Cited by 6,221
Blood flow measurements with radionuclide-labeled particles
Heymann, M. A., Payne, B. D., Hoffman, J. I. E., & Rudolph, A. M. (1977) · Progress in Cardiovascular Diseases · doi:10.1016/s0033-0620(77)80005-4 · Cited by 2,036
HYPSOMETRIC (AREA-ALTITUDE) ANALYSIS OF EROSIONAL TOPOGRAPHY
STRAHLER, A. N. (1952) · Geological Society of America Bulletin · doi:10.1130/0016-7606(1952)63[1117:haaoet]2.0.co;2 · Cited by 1,633
Handbook of Physiology—The Cardiovascular System
Guyton, A. C. (1985) · Critical Care Medicine · doi:10.1097/00003246-198505000-00025 · Cited by 1,147
In vivo measurements of “apparent viscosity” and microvessel hematocrit in the mesentery of the cat
Lipowsky, H. H., Usami, S., & Chien, S. (1980) · Microvascular Research · doi:10.1016/0026-2862(80)90050-3 · Cited by 398
Microvascular hematocrit and red cell flow in resting and contracting striated muscle
Klitzman, B., & Duling, B. R. (1979) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1979.237.4.h481 · Cited by 352
Barbee, J. H., & Cokelet, G. R. (1971) · Microvascular Research · doi:10.1016/0026-2862(71)90002-1 · Cited by 263 · cited 4×
“The velocitv ratio between blood and red cells observed TJ-JR = 5 u’c (2)”
BackgroundInfluentialCell distribution in capillary networks
Schmid-Schönbein, G. W., Skalak, R., Usami, S., & Chien, S. (1980) · Microvascular Research · doi:10.1016/0026-2862(80)90082-5 · Cited by 217
Nonuniform red cell distribution in 20 to 100 μm bifurcations
Fenton, B. M., Carr, R. T., & Cokelet, G. R. (1985) · Microvascular Research · doi:10.1016/0026-2862(85)90010-x · Cited by 180
Effect of velocity distribution on red cell distribution in capillary blood vessels
Yen, R. T., & Fung, Y. C. (1978) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1978.235.2.h251 · Cited by 157
Cited by
The endothelial glycocalyx: composition, functions, and visualization
Reitsma, S., Slaaf, D. W., Vink, H., van Zandvoort, M. A. M. J., & oude Egbrink, M. G. A. (2007) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s00424-007-0212-8 · Cited by 1,980
Pries, A. R., Secomb, T. W., & Gaehtgens, P. (2000) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s004240000307 · Cited by 898
Self-citationBiophysical aspects of blood flow in the microvasculature
Pries, A. R., Secomb, T. W., & Gaehtgens, P. (1996) · Cardiovascular Research · doi:10.1016/s0008-6363(96)00065-x · Cited by 553
Self-citationThe sex difference in haemoglobin levels in adults—mechanisms, causes, and consequences
Murphy, W. G. (2014) · Blood Reviews · doi:10.1016/j.blre.2013.12.003 · Cited by 463
Microvascular Rheology and Hemodynamics
LIPOWSKY, H. H. (2005) · Microcirculation · doi:10.1080/10739680590894966 · Cited by 414
The capillary bed offers the largest hemodynamic resistance to the cortical blood supply
Gould, I. G., Tsai, P., Kleinfeld, D., & Linninger, A. (2017) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1177/0271678x16671146 · Cited by 252
“0 Red Blood Cell Velocity, mm/s Cerebral Blood Perfusion*** mL/100g/min ● 78±16 (19-101) This Work 70-170 Xu(67) ● 142±57 Maeda(73) 40-65 Gertz(89) 0 40 80 120 160 200 Blood Perfusion, mL/100g/min Cerebral Oxygen Metabolism*** μmole/g/min ● 1.”
Koutsiaris, A. G., Tachmitzi, S. V., Batis, N., Kotoula, M. G., Karabatsas, C. H., Tsironi, E., & Chatzoulis, D. Z. (2007) · Biorheology: The Official Journal of the International Society of Biorheology · doi:10.1177/0006355x2007044005006008 · Cited by 244
“It should be noted that the aforementioned hematocrit values are referring to average values since it is clear from the high standard deviations of previous in vivo works [20,32] that instantly these values can be very different (microvascular heterogeneity [27,29]).”
BackgroundPassive blood plasma separation at the microscale: a review of design principles and microdevices
Tripathi, S., Varun Kumar, Y. V. B., Prabhakar, A., Joshi, S. S., & Agrawal, A. (2015) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/25/8/083001 · Cited by 223
Desjardins, C., & Duling, B. R. (1990) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1990.258.3.h647 · Cited by 221
Blood Flow in Microvascular Networks
Pries, A. R., & Secomb, T. W. (2008) · Microcirculation · doi:10.1016/b978-0-12-374530-9.00001-2 · Cited by 213
Self-citationLong, D. S., Smith, M. L., Pries, A. R., Ley, K., & Damiano, E. R. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402937101 · Cited by 210
Self-citationSkeletal muscle capillary hemodynamics from rest to contractions: implications for oxygen transfer
Kindig, C. A., Richardson, T. E., & Poole, D. C. (2002) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01222.2001 · Cited by 200
Geometrical focusing of cells in a microfluidic device: An approach to separate blood plasma
Faivre, M., Abkarian, M., Bickraj, K., & Stone, H. A. (2006) · Biorheology: The Official Journal of the International Society of Biorheology · doi:10.1177/0006355x2006043002001 · Cited by 196
“Indeed, one of the oldest and best known hemodynamic phenomenon of the microcirculation is the Fåhraeus effect [11,19], which refers to the decreased hematocrit concentration in small tubes relative to the larger reservoirs to which they are connected [1].”
Structural Adaptation and Heterogeneity of Normal and Tumor Microvascular Networks
Pries, A. R., Cornelissen, A. J. M., Sloot, A. A., Hinkeldey, M., Dreher, M. R., Höpfner, M., Dewhirst, M. W., & Secomb, T. W. (2009) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1000394 · Cited by 192
“Mesenteric vascular networks of three male wistar rats prepared for intravital microscopy were observed and analyzed as described previously [48].”
MethodSelf-citation
Metadata
- Authors
- Pries, A. R., Ley, K., & Gaehtgens, P.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1986-12-01
- Volume
- 251
- Issue
- 6
- Pages
- H1324-H1332
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W1496914563
- Cited by
- 198
- References
- 19
- FWCI
- 5.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.