The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Dynamic restitution of action potential duration during electrical alternans and ventricular fibrillation
Abstract
The restitution kinetics of action potential duration (APD) were investigated in paced canine Purkinje fibers (P; n = 9) and endocardial muscle (M; n = 9), in isolated, perfused canine left ventricles during ventricular fibrillation (VF; n = 4), and in endocardial muscle paced at VF cycle lengths (simulated VF; n = 4). Restitution was assessed with the use of two protocols: delivery of a single extrastimulus after a train of stimuli at cycle length = 300 ms (standard protocol), and fixed pacing at short cycle lengths (100–300 ms) that induced APD alternans (dynamic protocol). The dynamic protocol yielded a monotone increasing restitution function with a maximal slope of 1.13 ± 0.13 in M and 1.14 ± 0.17 in P. Iteration of this function reproduced the APD dynamics found experimentally, including persistent APD alternans. In contrast, the standard protocol yielded a restitution relation with a maximal slope of 0.57 ± 0.18 in M and 0.84 ± 0.20 in P, and iteration of this function did not reproduce the APD dynamics. During VF, the restitution kinetics at short diastolic interval were similar to those determined with the dynamic protocol (maximal slope: 1.72 ± 0.47 in VF and 1.44 ± 0.49 in simulated VF). Thus APD dynamics at short coupling intervals during fixed pacing and during VF were accounted for by the dynamic, but not the standard, restitution relation. These results provide further evidence for a strong relationship among the kinetics of electrical restitution, the occurrence of APD alternans, and complex APD dynamics during VF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrical Alternans and Vulnerability to Ventricular Arrhythmias
Rosenbaum, D. S., Jackson, L. E., Smith, J. M., Garan, H., Ruskin, J. N., & Cohen, R. J. (1994) · New England Journal of Medicine · doi:10.1056/nejm199401273300402 · Cited by 1,143
A graphic method for the study of alternation in cardiac action potentials.
Nolasco, J. B., & Dahlen, R. W. (1968) · Journal of Applied Physiology · doi:10.1152/jappl.1968.25.2.191 · Cited by 483
Electrical alternans and spiral wave breakup in cardiac tissue
Karma, A. (1994) · Chaos: An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/1.166024 · Cited by 479
Franz, M. R., Swerdlow, C. D., Liem, L. B., & Schaefer, J. (1988) · Journal of Clinical Investigation · doi:10.1172/jci113706 · Cited by 457
Analysis of the effects of changes in rate and rhythm upon electrical activity in the heart
Boyet, M. R., & Jewell, B. R. (1981) · Progress in Biophysics and Molecular Biology · doi:10.1016/0079-6107(81)90003-1 · Cited by 279
Low dimensional chaos in cardiac tissue
Chialvo, D. R., Gilmour Jr, R. F., & Jalife, J. (1990) · Nature · doi:10.1038/343653a0 · Cited by 232
Boyett, M. R., & Jewell, B. R. (1978) · The Journal of Physiology · doi:10.1113/jphysiol.1978.sp012576 · Cited by 217
Strydom, N. B., Graan, C. H. V., Morrison, J. F., Viljoen, J. H., & Heyns, A. (1968) · European Journal of Applied Physiology · doi:10.1007/bf00697663 · Cited by 187
Cycle length effect on restitution of action potential duration in dog cardiac fibers
Elharrar, V., & Surawicz, B. (1983) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1983.244.6.h782 · Cited by 184
Verrier, R. L., & Nearing, B. D. (1994) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1994.tb01184.x · Cited by 139
Cited by
A model for human ventricular tissue
ten Tusscher, K. H. W. J., Noble, D., Noble, P. J., & Panfilov, A. V. (2004) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00794.2003 · Cited by 1,416
Alternans and spiral breakup in a human ventricular tissue model
ten Tusscher, K. H. W. J., & Panfilov, A. V. (2006) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00109.2006 · Cited by 1,122
Basic Mechanisms of Cardiac Impulse Propagation and Associated Arrhythmias
KLÉBER, A. G., & RUDY, Y. (2004) · Physiological Reviews · doi:10.1152/physrev.00025.2003 · Cited by 1,083
Multiple mechanisms of spiral wave breakup in a model of cardiac electrical activity
Fenton, F. H., Cherry, E. M., Hastings, H. M., & Evans, S. J. (2002) · Chaos: An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/1.1504242 · Cited by 559
Preventing ventricular fibrillation by flattening cardiac restitution
Garfinkel, A., Kim, Y.-H., Voroshilovsky, O., Qu, Z., Kil, J. R., Lee, M.-H., Karagueuzian, H. S., Weiss, J. N., & Chen, P.-S. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.090492697 · Cited by 530
Metadata
- Authors
- Koller, M. L., Riccio, M. L., & Jr., R. F. G.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1998-11-01
- Volume
- 275
- Issue
- 5
- Pages
- H1635-H1642
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2101482473
- Cited by
- 358
- References
- 15
- FWCI
- 5.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dynamic restitution of action potential duration during electrical alternans and ventricular fibrillation. https://app.cochat.ai/papers/10.1152/ajpheart.1998.275.5.h1635
- The paper
- Koller, M. L., Riccio, M. L., & Jr., R. F. G. (1998). Dynamic restitution of action potential duration during electrical alternans and ventricular fibrillation. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1998.275.5.h1635
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.