CoChat

Cardiac muscle tissue engineering: toward an in vitro model for electrophysiological studies

Bursac, N., Papadaki, M., Cohen, R. J., Schoen, F. J., Eisenberg, S. R., Carrier, R., Vunjak-Novakovic, G., Freed, L. E. · 1999 · American Journal of Physiology-Heart and Circulatory Physiology
Cited by 366

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Abstract

The objective of this study was to establish a three-dimensional (3-D) in vitro model system of cardiac muscle for electrophysiological studies. Primary neonatal rat ventricular cells containing lower or higher fractions of cardiac myocytes were cultured on polymeric scaffolds in bioreactors to form regular or enriched cardiac muscle constructs, respectively. After 1 wk, all constructs contained a peripheral tissue-like region (50–70 μm thick) in which differentiated cardiac myocytes were organized in multiple layers in a 3-D configuration. Indexes of cell size (protein/DNA) and metabolic activity (tetrazolium conversion/DNA) were similar for constructs and neonatal rat ventricles. Electrophysiological studies conducted using a linear array of extracellular electrodes showed that the peripheral region of constructs exhibited relatively homogeneous electrical properties and sustained macroscopically continuous impulse propagation on a centimeter-size scale. Electrophysiological properties of enriched constructs were superior to those of regular constructs but inferior to those of native ventricles. These results demonstrate that 3-D cardiac muscle constructs can be engineered with cardiac-specific structural and electrophysiological properties and used for in vitro impulse propagation studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajpheart.1999.277.2.h433

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 17

  1. 10.1109/10.16473 · doi:10.1109/10.16473
  2. Freed L. E., 1994, Biotechnology, 12, 689
  3. 10.1111/j.1540-8167.1996.tb00478.x · doi:10.1111/j.1540-8167.1996.tb00478.x
  4. Kunysz A., 1995, Am. J. Physiol., 269, H1153
  5. Leor J., 1996, Circulation, 94, II-322
  6. 10.1253/jcj.57.912 · doi:10.1253/jcj.57.912
  7. 10.1109/51.646223 · doi:10.1109/51.646223
  8. 10.1002/jcp.1041170307 · doi:10.1002/jcp.1041170307
  9. 10.1016/S0022-2828(87)80356-5 · doi:10.1016/s0022-2828(87)80356-5
  10. 10.1002/bit.260430817 · doi:10.1002/bit.260430817
  11. 10.1111/j.1749-6632.1990.tb15081.x · doi:10.1111/j.1749-6632.1990.tb15081.x
  12. 10.1093/cvr/27.3.459 · DOI
  13. 10.1292/jvms.54.711 · doi:10.1292/jvms.54.711
  14. 10.1016/S0008-6363(97)00076-X · doi:10.1016/s0008-6363(97)00076-x
  15. 10.1111/j.1749-6632.1990.tb15083.x · doi:10.1111/j.1749-6632.1990.tb15083.x
  16. Xie L., 1997, Am. J. Physiol., 272, H1741
  17. Yin H., 1997, Am. J. Physiol., 272, H299

Cited by

See all 366

Metadata

Authors
Bursac, N., Papadaki, M., Cohen, R. J., Schoen, F. J., Eisenberg, S. R., Carrier, R., Vunjak-Novakovic, G., & Freed, L. E.
Venue
American Journal of Physiology-Heart and Circulatory Physiology
Published
1999-08-01
Volume
277
Issue
2
Pages
H433-H444
ISSN
  • 0363-6135 (ISSN-L)
  • 1522-1539
OpenAlex
W2134053621
Cited by
366
References
29
FWCI
7.46
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).