Echocardiographic assessment of cardiac function in conscious and anesthetized mice
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Using a high-frequency linear transducer (15L8), we studied 1) the feasibility of performing echocardiography in nonanesthetized mice compared with mice given pentobarbital sodium (Pento) or a mixture of ketamine and xylazine and 2) the feasibility of echocardiographic evaluation of left ventricular (LV) hypertrophy, dilatation, and function in mice with two-kidney, one-clip hypertension or myocardial infarction (MI). Heart rate (HR) in awake mice was 658 ± 9 beats/min; Pento and ketamine plus xylazine reduced HR to 377 ± 11 and 293 ± 19 beats/min, respectively, associated with a significant decrease in shortening fraction (SF), ejection fraction (EF), and cardiac output (CO) and an increase in LV end-diastolic (LVEDD) and end-systolic dimensions (LVESD). Mice with 4 wk of two-kidney, one-clip hypertension had increased LV mass (15.62 ± 0.62 vs. 22.17 ± 1.79 mg) without altered LV dimensions, SF, EF, or CO. Mice studied 4 wk post-MI exhibited obvious LV dilatation and systolic dysfunction, as evidenced by increased LVEDD and LVESD and decreased SF, EF, and CO. Our findings clearly show the adverse impact of anesthesia on basal cardiac function and the difficulty in interpreting data obtained from anesthetized mice. We believe this is the first study to demonstrate the feasibility of using echocardiography to assess cardiovascular function in the nonanesthetized mouse.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sahn, D. J., DeMaria, A., Kisslo, J., & Weyman, A. (1978) · Circulation · doi:10.1161/01.cir.58.6.1072 · Cited by 7,430
Enhanced Myocardial Function in Transgenic Mice Overexpressing the β 2 -Adrenergic Receptor
Milano, C. A., Allen, L. F., Rockman, H. A., Dolber, P. C., McMinn, T. R., Chien, K. R., Johnson, T. D., Bond, R. A., & Lefkowitz, R. J. (1994) · Science · doi:10.1126/science.8160017 · Cited by 740
Liu, Y. H., Yang, X. P., Sharov, V. G., Nass, O., Sabbah, H. N., Peterson, E., & Carretero, O. A. (1997) · Journal of Clinical Investigation · doi:10.1172/jci119360 · Cited by 603
Self-citationA Noninvasive Computerized Tail-Cuff System for Measuring Blood Pressure in Mice
Krege, J. H., Hodgin, J. B., Hagaman, J. R., & Smithies, O. (1995) · Hypertension · doi:10.1161/01.hyp.25.5.1111 · Cited by 587
Transthoracic Echocardiography in Models of Cardiac Disease in the Mouse
Tanaka, N., Dalton, N., Mao, L., Rockman, H. A., Peterson, K. L., Gottshall, K. R., Hunter, J. J., Chien, K. R., & Ross, J. (1996) · Circulation · doi:10.1161/01.cir.94.5.1109 · Cited by 364
Hoit, B. D., Khoury, S. F., Kranias, E. G., Ball, N., & Walsh, R. A. (1995) · Circulation Research · doi:10.1161/01.res.77.3.632 · Cited by 241
Echocardiographic Assessment of Left Ventricular Mass and Systolic Function in Mice
Gardin, J. M., Siri, F. M., Kitsis, R. N., Edwards, J. G., & Leinwand, L. A. (1995) · Circulation Research · doi:10.1161/01.res.76.5.907 · Cited by 220
Two-Kidney, One Clip and One-Kidney, One Clip Hypertension in Mice
Wiesel, P., Mazzolai, L., Nussberger, J., & Pedrazzini, T. (1997) · Hypertension · doi:10.1161/01.hyp.29.4.1025 · Cited by 179
Effect of High Salt Intake in Mutant Mice Lacking Bradykinin-B 2 Receptors
Alfie, M. E., Sigmon, D. H., Pomposiello, S. I., & Carretero, O. A. (1997) · Hypertension · doi:10.1161/01.hyp.29.1.483 · Cited by 154
Self-citationYang, X.-P., Liu, Y.-H., Shesely, E. G., Bulagannawar, M., Liu, F., & Carretero, O. A. (1999) · Hypertension · doi:10.1161/01.hyp.34.1.24 · Cited by 150
Self-citationBarbee, R. W., Perry, B. D., Re, R. N., & Murgo, J. P. (1992) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1992.263.3.r728 · Cited by 131
Echocardiographic and cardiac doppler assessment of mice
Pollick, C., Hale, S. L., & Kloner, R. A. (1995) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(05)80373-6 · Cited by 126
Chronic heart failure induced by coronary artery ligation in Lewis inbred rats
Liu, Y., Yang, X. P., Nass, O., Sabbah, H. N., Peterson, E. L., & Carretero, O. A. (1997) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1997.272.2.h722 · Cited by 124
Self-citationRole of Kinins in the Cardioprotective Effect of Preconditioning
Yang, X.-P., Liu, Y.-H., Scicli, G. M., Webb, C. R., & Carretero, O. A. (1997) · Hypertension · doi:10.1161/01.hyp.30.3.735 · Cited by 110
Self-citationLorenz, J. N., & Robbins, J. M. (1997) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1997.272.3.h1137 · Cited by 106
Çakır, B., Yönem, A., Güler, S., Odabaşı, E., Demi̇rbaş, B., Gürsoy, G., & Aral, Y. (1999) · Hormone Research in Paediatrics · doi:10.1159/000023495 · Cited by 43
Effect of Anesthetics on the Heart
Merin, R. G. (1975) · Surgical Clinics of North America · doi:10.1016/s0039-6109(16)40679-1 · Cited by 36
Pharmacology of Injectable Anesthetics
Fish, R. E. (1997) · Elsevier eBooks · doi:10.1016/b978-012417570-9/50004-0 · Cited by 35
SIMONE, G. D., Devereux, R. B., Volpe, M., Camargo, M. J. F., Wallerson, D. C., & Laragh, J. H. (1996) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1996.270.2.h628 · Cited by 19
Cited by
Shiojima, I. (2005) · Journal of Clinical Investigation · doi:10.1172/jci24682 · Cited by 939
Allometric Scaling of M-Mode Cardiac Measurements in Normal Adult Dogs
Cornell, C. C., Kittleson, M. D., Torre, P. D., Häggström, J., Lombard, C. W., Pedersen, H. D., Vollmar, A., & Wey, A. (2004) · Journal of Veterinary Internal Medicine · doi:10.1111/j.1939-1676.2004.tb02551.x · Cited by 811
Bøtker, H. E., Hausenloy, D., Andreadou, I., Antonucci, S., Boengler, K., Davidson, S. M., Deshwal, S., Devaux, Y., Di Lisa, F., Di Sante, M., et al. (2018) · Basic Research in Cardiology · doi:10.1007/s00395-018-0696-8 · Cited by 423
Guidelines for measuring cardiac physiology in mice
Lindsey, M. L., Kassiri, Z., Virag, J. A. I., de Castro Brás, L. E., & Scherrer-Crosbie, M. (2018) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00339.2017 · Cited by 349
Impact of anesthesia on cardiac function during echocardiography in mice
Roth, D. M., Swaney, J. S., Dalton, N. D., Gilpin, E. A., & Ross, J. (2002) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00845.2001 · Cited by 346
Metadata
- Authors
- Yang, X.-P., Liu, Y.-H., Rhaleb, N.-E., Kurihara, N., Kim, H. E., & Carretero, O. A.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1999-11-01
- Volume
- 277
- Issue
- 5
- Pages
- H1967-H1974
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W1825664270
- Cited by
- 365
- References
- 19
- FWCI
- 9.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.