Left ventricular torsion is equal in mice and humans
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Global cardiac function has been studied in small animals with methods such as echocardiography, cine-magnetic resonance imaging (MRI), and cardiac catheterization. However, these modalities make little impact on delineation of pathophysiology at the tissue level. The advantage of tagged cine-MRI technique is that the twisting motion of the ventricle, referred to as torsion, can be measured noninvasively, reflecting the underlying shearing motion of individual planes of myofibrils that generate wall thickening and ventricular ejection. Thus we sought to determine whether the mechanism of ventricular ejection, as measured by torsion, was the same in both humans and mice. Nine mice and ten healthy humans were studied with tagged cine-MRI. The magnitude and systolic time course of ventricular torsion were equivalent in mouse and humans, when normalized for heart rate and ventricular length. The end-systolic torsion angle was 12.7 ± 1.7° in humans vs. 2.0 ± 1.5° in mice unnormalized and 1.9 ± 0.3°/cm vs. 2.7 ± 2.3°/cm when normalized for ventricular length). These results support the premise that ventricular torsion may be a uniform measure of normal ventricular ejection across mammalian species and heart sizes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fiber Orientation in the Canine Left Ventricle during Diastole and Systole
STREETER, D. D., SPOTNITZ, H. M., PATEL, D. P., ROSS, J., & SONNENBLICK, E. H. (1969) · Circulation Research · doi:10.1161/01.res.24.3.339 · Cited by 1,454
Human heart: tagging with MR imaging--a method for noninvasive assessment of myocardial motion.
Zerhouni, E. A., Parish, D. M., Rogers, W. J., Yang, A., & Shapiro, E. P. (1988) · Radiology · doi:10.1148/radiology.169.1.3420283 · Cited by 1,430
Lorenz, C., Walker, E., Morgan, V., Klein, S., & Graham, T. (1999) · Journal of Cardiovascular Magnetic Resonance · doi:10.3109/10976649909080829 · Cited by 717
Self-citationHeart wall motion: improved method of spatial modulation of magnetization for MR imaging.
Axel, L., & Dougherty, L. (1989) · Radiology · doi:10.1148/radiology.172.2.2748813 · Cited by 597
DENSE: Displacement Encoding with Stimulated Echoes in Cardiac Functional MRI
Aletras, A. H., Ding, S., Balaban, R. S., & Wen, H. (1999) · Journal of Magnetic Resonance · doi:10.1006/jmre.1998.1676 · Cited by 526 · cited 1×
“Torsion may be measured using tagging as demonstrated here or with phase contrast MRI to measure myocardial velocities or displacements (1, 11, 46).”
MethodLitwin, S. E., Katz, S. E., Morgan, J. P., & Douglas, P. S. (1994) · Circulation · doi:10.1161/01.cir.89.1.345 · Cited by 421
Stuber, M., Scheidegger, M. B., Fischer, S. E., Nagel, E., Steinemann, F., Hess, O. M., & Boesiger, P. (1999) · Circulation · doi:10.1161/01.cir.100.4.361 · Cited by 368
Transthoracic Echocardiography in Models of Cardiac Disease in the Mouse
Tanaka, N., Dalton, N., Mao, L., Rockman, H. A., Peterson, K. L., Gottshall, K. R., Hunter, J. J., Chien, K. R., & Ross, J. (1996) · Circulation · doi:10.1161/01.cir.94.5.1109 · Cited by 364
Buchalter, M. B., Weiss, J. L., Rogers, W. J., Zerhouni, E. A., Weisfeldt, M. L., Beyar, R., & Shapiro, E. P. (1990) · Circulation · doi:10.1161/01.cir.81.4.1236 · Cited by 360
LeGrice, I. J., Takayama, Y., & Covell, J. W. (1995) · Circulation Research · doi:10.1161/01.res.77.1.182 · Cited by 314
Cited by
Helle-Valle, T., Crosby, J., Edvardsen, T., Lyseggen, E., Amundsen, B. H., Smith, H.-J., Rosen, B. D., Lima, J. A. C., Torp, H., Ihlen, H., et al. (2005) · Circulation · doi:10.1161/circulationaha.104.531558 · Cited by 705
Twist Mechanics of the Left Ventricle
Sengupta, P. P., Tajik, A. J., Chandrasekaran, K., & Khandheria, B. K. (2008) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2008.02.006 · Cited by 604
Left Ventricular Structure and Function
Sengupta, P. P., Korinek, J., Belohlavek, M., Narula, J., Vannan, M. A., Jahangir, A., & Khandheria, B. K. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.08.030 · Cited by 505
Sengupta, P. P., Krishnamoorthy, V. K., Korinek, J., Narula, J., Vannan, M. A., Lester, S. J., Tajik, J. A., Seward, J. B., Khandheria, B. K., & Belohlavek, M. (2007) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2006.10.013 · Cited by 323
Mizuguchi, Y., Oishi, Y., Miyoshi, H., Iuchi, A., Nagase, N., & Oki, T. (2008) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2008.07.016 · Cited by 248
“Therefore, torsion is defined as the difference between the basal and the apical rotation, and was divided by end-diastolic LV longitudinal length between the LV apex and the mitral plane.(11,12) We recorded LV rotation and rotational velocity profiles during a cardiac cycle at the base and apex using the software pac…”
MethodKim, H.-K., Sohn, D.-W., Lee, S.-E., Choi, S.-Y., Park, J.-S., Kim, Y.-J., Oh, B.-H., Park, Y.-B., & Choi, Y.-S. (2007) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2006.07.007 · Cited by 201
Left Ventricular Rotation and Twist: Why Should We Learn?
Nakatani, S. (2011) · Journal of Cardiovascular Ultrasound · doi:10.4250/jcu.2011.19.1.1 · Cited by 190
Rüssel, I. K., Götte, M. J. W., Bronzwaer, J. G., Knaapen, P., Paulus, W. J., & van Rossum, A. C. (2009) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2009.03.001 · Cited by 183
Notomi, Y., Srinath, G., Shiota, T., Martin-Miklovic, M. G., Beachler, L., Howell, K., Oryszak, S. J., Deserranno, D. G., Freed, A. D., Greenberg, N. L., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.537639 · Cited by 176
Jung, B., Odening, K. E., Dall'Armellina, E., Föll, D., Menza, M., Markl, M., & Schneider, J. E. (2012) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-14-87 · Cited by 44
“Furthermore, the lower spatial resolution provided by the tag grid pattern may limit the detection of these subtle short-range differences in the rotational motion pattern [32,33].”
BackgroundResultSmall animal cardiovascular MR imaging and spectroscopy
Bakermans, A. J., Abdurrachim, D., Moonen, R. P. M., Motaal, A. G., Prompers, J. J., Strijkers, G. J., Vandoorne, K., & Nicolay, K. (2015) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2015.03.001 · Cited by 35
Metadata
- Authors
- Henson, R. E., Song, S. K., Pastorek, J. S., Ackerman, J. J. H., & Lorenz, C. H.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2000-04-01
- Volume
- 278
- Issue
- 4
- Pages
- H1117-H1123
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2154748735
- Cited by
- 178
- References
- 30
- FWCI
- 3.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.