The DOI matches its Crossref record.
THE RANGE AND VARIABILITY OF THE BLOOD FLOW IN THE HUMAN FINGERS AND THE VASOMOTOR REGULATION OF BODY TEMPERATURE
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The variation in the quasi-DC component is due to many factors: the optical properties of the tissue, average blood volume, respiration, vasomotor activity, vasoconstrictor waves, Traube Hering Meyer waves, and thermoregulation [4,5,6,7,8,9,10,11,12,13,14].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [5]
Citations
Cited by
Sorted by citations
Items 301–332 of 332
Intra-Arterial Injection of Dextropropoxyphene into Hand Arteries
Siana, J. E., & Støvring, J. (1989) · Journal of Hand Surgery (European Volume) · doi:10.1016/0266-7681(89)90012-0
“The flow in the superficial and the deep palmar arterial arch is established at 200 ml/minute and in the common palmar digital arteries and the proper digital artery at 40 ml/minute (Burton, 1939).”
BackgroundIntrathecal phentolamine increases blood flow and skin temperature in the hind limbs of dogs
Sato, S., Okubo, N., & Naito, H. (1994) · Journal of Anesthesia · doi:10.1007/bf02514713
“Increased blood flow can be explained by a diminished sympathetic tone, and elevated P-skin temperature in a sign of increased blood flow in arteriovenous anastomosis at the tips of the extremities [9].”
BackgroundEvans (1966) Exchange and the Skin in the Light of Vacuum-Assisted Closure, Yoga, and Maggots
Ryan, T. J. (2004) · The International Journal of Lower Extremity Wounds · doi:10.1177/1534734604268011
“5-1 ml per minute per 100 ml tissue.(2) Studies of healthy skin showed that it could survive oxygen deprivation for hours.”
BackgroundSCUPHAM, G. W. (1940) · Archives of Internal Medicine · doi:10.1001/archinte.1940.00190150178013
Kondrat’ev, E. N. (1960) · Bulletin of Experimental Biology and Medicine · doi:10.1007/bf00780352
Spectral Analysis of Cardiorespiratory Signals
Risk, M. R., Sobh, J. F., Armentano, R. L., Ramirez, A. J., & Saul, J. P. (1997) · Birkhäuser Boston eBooks · doi:10.1007/978-1-4612-2010-7_8
Assessment of the viability of skin grafts
Wahner, H. W. (1988) · Seminars in Nuclear Medicine · doi:10.1016/s0001-2998(88)80033-3
Prevention of Peri-Anesthetic Hypothermia by Regulating Cutaneous Micro-Circulation: a Rodent Model
Nesher, N., Frolkis, I., Ganiel, A., Ben‐Gal, Y., Paz, Y., Kramer, A., & Pevni, D. (2015) · Journal of Applied Pharmaceutical Science · doi:10.7324/japs.2015.50617
“These anastomoses play an important role in temperature regulation, since their synchronous closing, caused by efferent sympathetic impulse bursts (Hensel 1981, Roddie 2003), is linked to heat balance (Burton 1939).”
BackgroundResultMerla, A., Donato, L., Luzio, S. D., et al. (2002)
Chen, Y. (2012) · doi:10.32657/10356/50792
“vasomotor activity, body movement and body temperature [143-156].”
BackgroundA. Assessment of Antianginal Drugs Through Studies of the Peripheral Circulation
Roddie, I. C., & Wallace, W. F. M. (1985)
Noordergraaf, A. (1978) · Elsevier eBooks · doi:10.1016/b978-0-12-520950-2.50008-7
Thermal Entrainment of Peripheral Blood Flow
Mearns, A. J., & Harness, J. B. (1981) · Springer eBooks · doi:10.1007/978-3-642-68172-1_135
A relationship between cardiac sinus arrhythmia blood pressure and skin vasomotor activity in man
Stefánsson, S. B. (1986) · Spiral (Imperial College London)
Performance Analysis of an Activity Based Measurement of Blood Flow Using Impedance Plethysmography
Kumar, R. H., Babu, C. G., Sampath, P., & Ramkumar, M. (2013) · Lecture notes in electrical engineering · doi:10.1007/978-81-322-1000-9_4
Ramkumar, M., & Babu, C. G. (2017) · SSRN Electronic Journal · doi:10.2139/ssrn.2942416
Blažek, V. (2021) · Biological and medical physics, biomedical engineering · doi:10.1007/978-981-15-5449-0_1 · Cited by 1
McNabb, L. J. (2021) · Brock University Digital Repository (Brock University)
Shitzer, A., Bellomo, S., Stroschein, L. A., et al. (2003) · Springer eBooks · doi:10.1007/0-306-48329-7_13
(1957) · Acta Medica Scandinavica · doi:10.1111/j.0954-6820.1957.tb04568.x
(1972) · Acta Medica Scandinavica · doi:10.1111/j.0954-6820.1972.tb03610.x
Roddie, I. C., & Wallace, W. F. M. (1985) · Handbook of experimental pharmacology · doi:10.1007/978-3-642-69524-7_6
WOLLHEIM, E., & Zissler, J. (1960) · Springer eBooks · doi:10.1007/978-3-662-36544-1_1
Adolfson, J., Sperling, L., & Gustavsson, M. (1985) · Springer eBooks · doi:10.1007/978-94-011-9655-0_21
(1975) · Elsevier eBooks · doi:10.1016/b978-0-407-41280-4.50024-4
Standardization of Finger Systolic Blood Pressure (FSBP) Cooling Tests
Olsen, N. V. (2005) · Environmental Health and Preventive Medicine · doi:10.1265/ehpm.10.360
Photoplethysmogram Parameters Change Depending on Sensor Positioning
Kolokolnikov, I., Savchenko, E. A., & Nepomnyaschaya, E. (2022) · International Conference on Electrical Engineering and Photonics (EExPolytech) · doi:10.1109/eexpolytech56308.2022.9950818
Jabri, M., Masoumi, S., Kandukuri, T. R., et al. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4796750
Interactions Between Respiration and Circulation
Daly, M. D. B. (1986) · Comprehensive physiology · doi:10.1002/j.2040-4603.1986.tb01066.x
Circulation to Skin and Adipose Tissue
Roddie, I. C. (1983) · Comprehensive physiology · doi:10.1002/j.2040-4603.1983.tb00990.x
A thermal peripheral blood flowmeter with contact force compensation
Sim, J. K., Youn, S., & Cho, Y.-H. (2012) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/22/12/125014 · Cited by 10
Metadata
- Authors
- Burton, A. C.
- Affiliations
- University of Pennsylvania (US)
- Corresponding author
- Burton, A. C.
- ORCID
- Burton, A. C.
- Venue
- American Journal of Physiology-Legacy Content
- Publisher
- American Physiological Society
- Published
- 1939-09-30
- Volume
- 127
- Issue
- 3
- Pages
- 437-453
- ISSN
- 0002-9513 (ISSN-L)
- OpenAlex
- W2214038234
- Cited by
- 333
- References
- 0
- Citations by year
- 2025: 1 · 2024: 3 · 2023: 2 · 2022: 2 · 2021: 9 · 2020: 2 · 2019: 3 · 2018: 7 · 2017: 5 · 2016: 7 · 2015: 6 · 2014: 8 · 2013: 8 · 2012: 5
- FWCI
- 10.87
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Journal of Physiology-Legacy Content (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Thermoregulation and physiological responses
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- finger blood flow, regional blood flow, vasomotor control, thermoregulation, skin blood flow, finger
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review