Formation of Peripheral Pulse Contour in Man
The DOI matches its Crossref record.
Abstract
The changes in pulse contour attending outward propagation were mapped through subclavian-brachial-radial and aorta-upper femoral artery systems. These changes could be placed into three categories. a) In elastic aorta and upper subclavian artery, the anacrotic slope was transmitted intact, that is, with little evidence of damping and with a delayed summation with a reflected wave. Pulse pressure increased, in relatively small amounts, probably because of a fusion between the primary and the reflected wave. This reflected component consisted of the first part of the primary form only. Unlike the dog, the human being did not show simultaneous pressure peaks in the aorta, nor was there clear evidence of later reciprocal oscillations. b) There were transition regions where the anacrotic slope steepened immediately, pulse pressure was clearly augmented, and, in the subclavian-upper arm system, a simultaneous pressure peak was developed. The amount of augmentation could not be explained on the basis of a single reflected wave, and if it is attributed to multiple reflections, the summed pressure height must have been propagated into the next segment of artery. c) In the muscular brachial-radial system, and upper femoral, anacrotic steepening and peak augmentation usually continued, but the peaks appeared propagated. The pulse contour of the arm system showed three pressure waves. Only the first showed simultaneous timing. Its size seemed to reflect the speed of anacrotic pressure rise of the central pulse. The second wave was dependent in part on maintenance of high pressure values in late systole in the central pulse. The third wave followed the incisural trough. If these waves represented wave reflections, the site of these reflections is not constant. It remains possible that these waves mark separate surges of blood into the arm and are thus propagated rather than 'resonating' waves. Only two waves were seen in the aorta, the first being the systolic peak of the central pulse as it was propagated outward, and the second following the incisura. Submitted on May 21, 1956
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pauca, A. L., O’Rourke, M. F., & Kon, N. D. (2001) · Hypertension · doi:10.1161/hy1001.096106 · Cited by 1,179
KARAMANOGLU, M., O'ROURKE, M. F., AVOLIO, A. P., & KELLY, R. P. (1993) · European Heart Journal · doi:10.1093/eurheartj/14.2.160 · Cited by 873
Mitchell, G. F., Moyé, L. A., Braunwald, E., Rouleau, J.-L., Bernstein, V., Geltman, E. M., Flaker, G. C., Pfeffer, M. A., & Investigators, F. T. S. (1997) · Circulation · doi:10.1161/01.cir.96.12.4254 · Cited by 531
Avolio, A. P., Van Bortel, L. M., Boutouyrie, P., Cockcroft, J. R., McEniery, C. M., Protogerou, A. D., Roman, M. J., Safar, M. E., Segers, P., & Smulyan, H. (2009) · Hypertension · doi:10.1161/hypertensionaha.109.134379 · Cited by 521
Structured tree outflow condition for blood flow in larger systemic arteries
Olufsen, M. S. (1999) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1999.276.1.h257 · Cited by 439
Kelly, R., & Fitchett, D. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90198-v · Cited by 361
Avolio, A. P., Butlin, M., & Walsh, A. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/1/r01 · Cited by 310
Indirect Systolic Pressures and Pulse Waves in Arterial Occlusive Disease of the Lower Extremities
CARTER, S. A. (1968) · Circulation · doi:10.1161/01.cir.37.4.624 · Cited by 308
Saba, P. S., Roman, M. J., Pini, R., Spitzer, M., Ganau, A., & Devereux, R. B. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90772-s · Cited by 266
The association between preeclampsia and arterial stiffness
Hausvater, A., Giannone, T., Sandoval, Y.-H. G., Doonan, R. J., Antonopoulos, C. N., Matsoukis, I. L., Petridou, E. T., & Daskalopoulou, S. S. (2012) · Journal of Hypertension · doi:10.1097/hjh.0b013e32834e4b0f · Cited by 195
Dorman, T., Breslow, M. J., Lipsett, P. A., Rosenberg, J. M., Balser, J. R., Almog, Y., & Rosenfeld, B. A. (1998) · Critical Care Medicine · doi:10.1097/00003246-199810000-00014 · Cited by 189
DHAKAM, Z., MCENIERY, C., YASMIN, COCKCROFT, J., BROWN, M., & WILKINSON, I. (2006) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2005.08.007 · Cited by 169
Arterial dilation and reduced wave reflection. Benefit of dilevalol in hypertension.
Kelly, R., Daley, J., Avolio, A., & O'Rourke, M. (1989) · Hypertension · doi:10.1161/01.hyp.14.1.14 · Cited by 166
“It was first described by Salans et al(34) and is apparent in the data of Remington et al.(35) There is a type of "standing wave" of pressure in the upper limb of human subjects such that pressure wavelets are reciprocal above and below a "node" of pressure in the proximal upper limb.”
Genesis of the normal and abnormal arterial pulse
Vlachopoulos, C., & O'Rourke, M. (2000) · Current Problems in Cardiology · doi:10.1067/mcd.2000.104057 · Cited by 125
Manisty, C. H., & Hughes, A. D. (2013) · British Journal of Clinical Pharmacology · doi:10.1111/j.1365-2125.2012.04342.x · Cited by 99
Armstrong, M. K., Schultz, M. G., Picone, D. S., Black, J. A., Dwyer, N., Roberts-Thomson, P., & Sharman, J. E. (2019) · Hypertension · doi:10.1161/hypertensionaha.119.12674 · Cited by 59
Metadata
- Authors
- Remington, J. W., & Wood, E. H.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1956-11
- Volume
- 9
- Issue
- 3
- Pages
- 433-442
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2246900510
- Cited by
- 129
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.