Computation of aortic flow from pressure in humans using a nonlinear, three-element model
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
We computed aortic flow pulsations from arterial pressure by simulating a nonlinear, time-varying three-element model of aortic input impedance. The model elements represent aortic characteristic impedance, arterial compliance, and systemic vascular resistance. Parameter values for the first two elements were computed from a published, age-dependent, aortic pressure-area relationship (G. J. Langewouters et al. J. Biomech. 17:425–435, 1984). Peripheral resistance was predicted from mean pressure and model mean flow. Model flow pulsations from aortic pressure showed the visual aspects of an aortic flow curve. For evaluation we compared model mean flow from radial arterial pressure with thermodilution cardiac output estimations, 76 times, in eight open heart surgical patients. The pooled mean difference was +7%, the SD 22%. After using one comparison per patient to calibrate the model, however, we followed quantitative changes in cardiac output that occurred either during changes in the state of the patient or subsequent to vasoactive drugs. The mean deviation from thermodilution cardiac output was +2%, the SD 8%. Given these small errors the method could monitor cardiac output continuously.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Langewouters, G. J., Wesseling, K. H., & Goedhard, W. J. A. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90034-4 · Cited by 544
Self-citationSprangers, R. L., Wesseling, K. H., Imholz, A. L., Imholz, B. P., & Wieling, W. (1991) · Journal of Applied Physiology · doi:10.1152/jappl.1991.70.2.523 · Cited by 179
Self-citationGrundlagen der Dynamik des Arterienpulses.
(1968) · Annals of Internal Medicine · doi:10.7326/0003-4819-69-6-1344_6 · Cited by 167
McDonald's blood flow in arteries, 3rd ed.
Bush, A. (1991) · International Journal of Cardiology · doi:10.1016/0167-5273(91)90372-v · Cited by 78
Cited by
Westerhof, N., Lankhaar, J.-W., & Westerhof, B. E. (2009) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-008-0359-2 · Cited by 1,181
Kass, D. A., Chen, C.-H., Curry, C., Talbot, M., Berger, R., Fetics, B., & Nevo, E. (1999) · Circulation · doi:10.1161/01.cir.99.12.1567 · Cited by 972
Fifteen years experience with finger arterial pressure monitoring: assessment of the technology
Imholz, B. (1998) · Cardiovascular Research · doi:10.1016/s0008-6363(98)00067-4 · Cited by 834
Assessment of cardiac output from systemic arterial pressure in humans
Romano, S. M., & Pistolesi, M. (2002) · Critical Care Medicine · doi:10.1097/00003246-200208000-00027 · Cited by 616
Jansen, J. R. C., Schreuder, J. J., Mulier, J. P., Smith, N. T., Settels, J. J., & Wesseling, K. H. (2001) · British Journal of Anaesthesia · doi:10.1093/bja/87.2.212 · Cited by 583
Self-citation
Metadata
- Authors
- Wesseling, K. H., Jansen, J. R., Settels, J. J., & Schreuder, J. J.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1993-05-01
- Volume
- 74
- Issue
- 5
- Pages
- 2566-2573
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2096774244
- Cited by
- 1,137
- References
- 4
- FWCI
- 5.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.