Computation of aortic flow from pressure in humans using a nonlinear, three-element model
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
We computed aortic flow pulsations from arterial pressure by simulating a nonlinear, time-varying three-element model of aortic input impedance. The model elements represent aortic characteristic impedance, arterial compliance, and systemic vascular resistance. Parameter values for the first two elements were computed from a published, age-dependent, aortic pressure-area relationship (G. J. Langewouters et al. J. Biomech. 17:425–435, 1984). Peripheral resistance was predicted from mean pressure and model mean flow. Model flow pulsations from aortic pressure showed the visual aspects of an aortic flow curve. For evaluation we compared model mean flow from radial arterial pressure with thermodilution cardiac output estimations, 76 times, in eight open heart surgical patients. The pooled mean difference was +7%, the SD 22%. After using one comparison per patient to calibrate the model, however, we followed quantitative changes in cardiac output that occurred either during changes in the state of the patient or subsequent to vasoactive drugs. The mean deviation from thermodilution cardiac output was +2%, the SD 8%. Given these small errors the method could monitor cardiac output continuously.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Langewouters, G. J., Wesseling, K. H., & Goedhard, W. J. A. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90034-4 · Cited by 544
Self-citationSprangers, R. L., Wesseling, K. H., Imholz, A. L., Imholz, B. P., & Wieling, W. (1991) · Journal of Applied Physiology · doi:10.1152/jappl.1991.70.2.523 · Cited by 179
Self-citationGrundlagen der Dynamik des Arterienpulses.
(1968) · Annals of Internal Medicine · doi:10.7326/0003-4819-69-6-1344_6 · Cited by 167
McDonald's blood flow in arteries, 3rd ed.
Bush, A. (1991) · International Journal of Cardiology · doi:10.1016/0167-5273(91)90372-v · Cited by 78
Cited by
Westerhof, N., Lankhaar, J.-W., & Westerhof, B. E. (2009) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-008-0359-2 · Cited by 1,181
Kass, D. A., Chen, C.-H., Curry, C., Talbot, M., Berger, R., Fetics, B., & Nevo, E. (1999) · Circulation · doi:10.1161/01.cir.99.12.1567 · Cited by 972
Fifteen years experience with finger arterial pressure monitoring: assessment of the technology
Imholz, B. (1998) · Cardiovascular Research · doi:10.1016/s0008-6363(98)00067-4 · Cited by 834
Assessment of cardiac output from systemic arterial pressure in humans
Romano, S. M., & Pistolesi, M. (2002) · Critical Care Medicine · doi:10.1097/00003246-200208000-00027 · Cited by 616
Jansen, J. R. C., Schreuder, J. J., Mulier, J. P., Smith, N. T., Settels, J. J., & Wesseling, K. H. (2001) · British Journal of Anaesthesia · doi:10.1093/bja/87.2.212 · Cited by 583
Self-citationCritchley, L. A., Lee, A., & Ho, A. M.-H. (2010) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181f08a5b · Cited by 512
Cerebral blood flow during exercise: mechanisms of regulation
Ogoh, S., & Ainslie, P. N. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00573.2009 · Cited by 502
Non‐invasive pulsatile arterial pressure and stroke volume changes from the human finger
Bogert, L. W. J., & van Lieshout, J. J. (2005) · Experimental Physiology · doi:10.1113/expphysiol.2005.030262 · Cited by 413
Review of Zero-D and 1-D Models of Blood Flow in the Cardiovascular System
Shi, Y., Lawford, P., & Hose, R. (2011) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-10-33 · Cited by 399
Syncope, cerebral perfusion, and oxygenation
Van Lieshout, J. J., Wieling, W., Karemaker, J. M., & Secher, N. H. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00260.2002 · Cited by 365
“As an example, modeling flow from arterial pressure by simulating a nonlinear three-element model of the aortic input impedance (180) has been applied to study changes in cerebral velocity and/or oxygenation and their relationship to changes in systemic hemodynamics (31, 51, 67, 69, 130, 131, 173).”
MethodShort‐term cardiovascular oscillations in man: measuring and modelling the physiologies
Cohen, M. A., & Taylor, J. A. (2002) · The Journal of Physiology · doi:10.1113/jphysiol.2002.017483 · Cited by 362
HARMS, M. P. M., WESSELING, K. H., POTT, F., JENSTRUP, M., VAN GOUDOEVER, J., SECHER, N. H., & VAN LIESHOUT, J. J. (1999) · Clinical Science · doi:10.1042/cs0970291 · Cited by 345
Self-citationHart, E. C., Charkoudian, N., Wallin, B. G., Curry, T. B., Eisenach, J., & Joyner, M. J. (2011) · The Journal of Physiology · doi:10.1113/jphysiol.2011.212753 · Cited by 338
“Beat-to-beat stroke volume was then calculated using Modelflow which computes an aortic waveform based on non-linear pressure–volume, pressure–compliance and pressure–characteristic impedance equations, incorporating age, sex, height and body mass (Wesseling et al. 1993).”
MethodEffect of gravity and microgravity on intracranial pressure
Lawley, J. S., Petersen, L. G., Howden, E. J., Sarma, S., Cornwell, W. K., Zhang, R., Whitworth, L. A., Williams, M. A., & Levine, B. D. (2017) · The Journal of Physiology · doi:10.1113/jp273557 · Cited by 312
Impaired Cerebral Autoregulation in Patients With Malignant Hypertension
Immink, R. V., van den Born, B.-J. H., van Montfrans, G. A., Koopmans, R. P., Karemaker, J. M., & van Lieshout, J. J. (2004) · Circulation · doi:10.1161/01.cir.0000144472.08647.40 · Cited by 243
Randomized Clinical Trial of Dialysate Cooling and Effects on Brain White Matter
Eldehni, M. T., Odudu, A., & McIntyre, C. W. (2015) · Journal of the American Society of Nephrology · doi:10.1681/asn.2013101086 · Cited by 237
Sugawara, J., Tanabe, T., Miyachi, M., Yamamoto, K., Takahashi, K., Iemitsu, M., Otsuki, T., Homma, S., Maeda, S., Ajisaka, R., et al. (2003) · Acta Physiologica Scandinavica · doi:10.1046/j.0001-6772.2003.01211.x · Cited by 230
Effects of hyperthermia on cerebral blood flow and metabolism during prolonged exercise in humans
Nybo, L., Møller, K., Volianitis, S., Nielsen, B., & Secher, N. H. (2002) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00049.2002 · Cited by 222
“In six of the eight subjects, cardiac output was estimated from the arterial pressure wave by a nonlinear, three-element model flow analysis (41).”
MethodFinometer, finger pressure measurements with the possibility to reconstruct brachial pressure
Guelen, I., Westerhof, B. E., van der Sar, G. L., van Montfrans, G. A., Kiemeneij, F., Wesseling, K. H., & Bos, W. J. W. (2003) · Blood Pressure Monitoring · doi:10.1097/00126097-200302000-00006 · Cited by 219
Self-citationPulse contour cardiac output derived from non‐invasive arterial pressure in cardiovascular disease
Bogert, L. W. J., Wesseling, K. H., Schraa, O., Van Lieshout, E. J., De Mol, B. A. J. M., Van Goudoever, J., Westerhof, B. E., & Van Lieshout, J. J. (2010) · Anaesthesia · doi:10.1111/j.1365-2044.2010.06511.x · Cited by 202
Self-citationChase, J. G., Preiser, J.-C., Dickson, J. L., Pironet, A., Chiew, Y. S., Pretty, C. G., Shaw, G. M., Benyo, B., Moeller, K., Safaei, S., et al. (2018) · BioMedical Engineering OnLine · doi:10.1186/s12938-018-0455-y · Cited by 189
“3 shows a specific model and equations for a model-based measure of stroke volume (SV) [161], based on similar prior models [201, 202].”
MethodCuffless Blood Pressure Measurement
Mukkamala, R., Stergiou, G. S., & Avolio, A. P. (2022) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-110220-014644 · Cited by 180
Age dependency of cardiovascular autonomic responses to head-up tilt in healthy subjects
Laitinen, T., Niskanen, L., Geelen, G., Länsimies, E., & Hartikainen, J. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00444.2003 · Cited by 176
“Stroke volume was assessed from the noninvasive blood pressure signal by using the arterial pulse contour method, which is modified from the model flow method (60).”
MethodA Novel Continuous Blood Pressure Estimation Approach Based on Data Mining Techniques
Miao, F., Fu, N., Zhang, Y.-T., Ding, X.-R., Hong, X., He, Q., & Li, Y. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2691715 · Cited by 174
Impaired cardiovascular recovery following stress predicts 3-year increases in blood pressure
Steptoe, A., & Marmot, M. (2005) · Journal of Hypertension · doi:10.1097/01.hjh.0000160208.66405.a8 · Cited by 171
Pearson, J., Low, D. A., Stöhr, E., Kalsi, K., Ali, L., Barker, H., & González-Alonso, J. (2011) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00662.2010 · Cited by 169
“1; Finapress Medical Systems, Amsterdam, Netherlands) (46).”
InfluentialFunctional Hemodynamic Monitoring
Pinsky, M. R. (2015) · Critical Care Clinics · doi:10.1016/j.ccc.2014.08.005 · Cited by 168
Noninvasive continuous hemodynamic monitoring
Truijen, J., van Lieshout, J. J., Wesselink, W. A., & Westerhof, B. E. (2012) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-012-9375-8 · Cited by 161
“Thus, patient data and arterial pressures are both needed to determine these Windkessel parameters [99].”
BackgroundMethodEstimation of changes in cardiac output from the arterial blood pressure waveform in the upper limb,
Linton, N. W. F., & Linton, R. A. F. (2001) · British Journal of Anaesthesia · doi:10.1093/bja/86.4.486 · Cited by 159
van Lieshout, J. J., ten Harkel, A. D. J., & Wieling, W. (2000) · Clinical Autonomic Research · doi:10.1007/bf02291388 · Cited by 144
Verheyden, B., Liu, J., van Dijk, N., Westerhof, B. E., Reybrouck, T., Aubert, A. E., & Wieling, W. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.09.003 · Cited by 101
Casey, D. P., Curry, T. B., Joyner, M. J., Charkoudian, N., & Hart, E. C. (2011) · Hypertension · doi:10.1161/hypertensionaha.110.164517 · Cited by 83
Figueroa, A., Trivino, J. A., Sanchez-Gonzalez, M. A., & Vicil, F. (2010) · American Journal of Hypertension · doi:10.1038/ajh.2009.195 · Cited by 79
Freitas, J., Santos, R., Azevedo, E., Costa, O., Carvalho, M., & Falcão de Freitas, A. (2000) · Clinical Autonomic Research · doi:10.1007/bf02281112 · Cited by 78
“Calculation of noninvasive hemodynamics To estimate cardiac output and total peripheral resistance, we chose a method developed by Wesseling [14] because of its simplicity, low cost, and noninvasive nature.”
MethodGisolf, J., Westerhof, B. E., van Dijk, N., Wesseling, K. H., Wieling, W., & Karemaker, J. M. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.04.038 · Cited by 59
Self-citationVerheyden, B., Gisolf, J., Beckers, F., Karemaker, J. M., Wesseling, K. H., Aubert, A. E., & Wieling, W. (2007) · Clinical Science · doi:10.1042/cs20070042 · Cited by 58
“Blood pressure was measured continuously and non-invasively using the Finapres Model 5 (TNO Biomedical Instrumentation, Amsterdam, the Netherlands).”
MethodSelf-citationNeural circulatory control in vasovagal syncope
VAN LIESHOUT, J. J., WIELING, W., & KAREMAKER, J. M. (1997) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1997.tb03901.x · Cited by 52
Huisman, H. W., Schutte, A. E., Schutte, R., van Rooyen, J. M., Fourie, C. M. T., Mels, C. M. C., Smith, W., Malan, N. T., & Malan, L. (2013) · American Journal of Hypertension · doi:10.1093/ajh/hps007 · Cited by 32
The effects of oral smokeless tobacco administration on endurance performance
Zandonai, T., Tam, E., Bruseghini, P., Pizzolato, F., Franceschi, L., Baraldo, M., Capelli, C., Cesari, P., & Chiamulera, C. (2018) · Journal of Sport and Health Science · doi:10.1016/j.jshs.2016.12.006 · Cited by 15
Uppal, J., Baker, J. R., Hira, R., Karalasingham, K., Ranada, S., Deol, P., Sheldon, R. S., & Raj, S. R. (2025) · Autonomic Neuroscience · doi:10.1016/j.autneu.2025.103281 · Cited by 13
“The beat-to-beat blood pressure waveform was analyzed to obtain estimates of stroke volume (ml), cardiac output (l/min), and systemic vascular resistance (SVR) (dyn*s*cm-5) using Modelflow waveform analysis (Wesseling et al., 1993).”
Evaluation of stroke volume estimation during orthostatic stress: the utility of Modelflow
Lucci, V.-E. M., Parsons, I. T., Hockin, B. C. D., & Claydon, V. E. (2023) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000671 · Cited by 12
Parks, J. C., Joplin, M. C. P., Marshall, E. M., Kearney, S. G., Humm, S. M., Kern, M. A., Pinzone, A. G., Erb, E. K., Smith, T. M., & Kingsley, J. D. (2023) · European Journal of Applied Physiology · doi:10.1007/s00421-023-05260-x · Cited by 8
Uppal, J., Deol, P., Giri, P., Singh, A., Hamzeh, R., Qi, J., Chew, D. S., Runte, M., Sheldon, R. S., & Raj, S. R. (2026) · JACC: Advances · doi:10.1016/j.jacadv.2026.102795 · Cited by 1
Metadata
- Authors
- Wesseling, K. H., Jansen, J. R., Settels, J. J., & Schreuder, J. J.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1993-05-01
- Volume
- 74
- Issue
- 5
- Pages
- 2566-2573
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2096774244
- Cited by
- 1,137
- References
- 4
- FWCI
- 5.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.