Changes in airway resistance induced by nasal inhalation of cold dry, dry, or moist air in normal individuals
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Fontanari, Pierre, Henri Burnet, Marie Caroline Zattara-Hartmann, and Yves Jammes. Changes in airway resistance induced by nasal inhalation of cold dry, dry, or moist air in normal individuals. J. Appl. Physiol. 81(4): 1739–1743, 1996.—Nasopulmonary bronchomotor reflexes elicited by mechanical or irritant stimulation of the nose have been described in animals and asthmatic patients. However, few studies were devoted to the consequences of nasal breathing of cold and dry air or of only dry or only moist air on the bronchomotor control in normal individuals. The present study reported changes in interruption resistance (Rint) measured during eupneic breathing of moderately cold (−4 or −10°C) and dry [0.3% relative humidity (RH)] air or of room air at 23°C that is either dry (0.3% RH) or moist (97% RH). Nasal inhalation of cold (−4°C) dry air or of only dry air significantly increased baseline Rint value (17 and 21%, respectively) throughout the 15-min test periods. The response to cold was significantly accentuated when the air temperature was lowered to −10°C (42%). After nasal anesthesia or inhalation of a cholinergic antagonist, cold air did not induce a change in Rint. Nasal inhalation of moist room air had no effect. No Rint changes were measured during oral breathing of the three test agents. It is concluded that the activation of cold receptors or osmoreceptors in the nasal mucosa induces protective bronchoconstrictor responses in normal individuals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DuBois, A. B., Botelho, S. Y., & Comroe, J. H. (1956) · Journal of Clinical Investigation · doi:10.1172/jci103282 · Cited by 1,277
The effect of nasal and nasopharyngeal irritation on airway resistance in man.
Kaufman, J., & Wright, G. W. (1969) · PubMed · doi:10.1164/arrd.1969.100.5.626 · Cited by 134 · cited 1×
“The existence of nasopulmonary reflexes elicited by nasal irritation is suspected in normal subjects (5, 9, 10, 17) as well as in patients suffering from asthma and/or rhinitis (14, 18, 21).”
BackgroundA physiological stimulus to upper airway receptors in humans
McBride, B., & Whitelaw, W. A. (1981) · Journal of Applied Physiology · doi:10.1152/jappl.1981.51.5.1189 · Cited by 125 · cited 1×
“Fresh air (2 or 25 °C) inhalation through the nose changed the ventilatory pattern with decreased minute ventilation, whereas warm air breathing had no effect (1, 13, 15).”
BackgroundSluder, G. (1919) · JAMA · doi:10.1001/jama.1919.02610340021006 · Cited by 85 · cited 1×
“The existence of nasopulmonary reflexes elicited by nasal irritation is suspected in normal subjects (5, 9, 10, 17) as well as in patients suffering from asthma and/or rhinitis (14, 18, 21).”
BackgroundKaufman, J., Chen, J. C., & Wright, G. W. (1970) · PubMed · doi:10.1164/arrd.1970.101.5.768 · Cited by 83 · cited 1×
“The existence of nasopulmonary reflexes elicited by nasal irritation is suspected in normal subjects (5, 9, 10, 17) as well as in patients suffering from asthma and/or rhinitis (14, 18, 21).”
BackgroundThe response of the airways to nasal stimulation in asthmatics with rhinitis.
Ke, Y., & SALOME, C. M. (1983) · PubMed · Cited by 78
Effects of nasal cold receptors on pattern of breathing
Burgess, K. R., & Whitelaw, W. A. (1988) · Journal of Applied Physiology · doi:10.1152/jappl.1988.64.1.371 · Cited by 73 · cited 1×
“Fresh air (2 or 25 °C) inhalation through the nose changed the ventilatory pattern with decreased minute ventilation, whereas warm air breathing had no effect (1, 13, 15).”
BackgroundTrigeminal nasal receptors related to respiration and to various stimuli in cats
Wallois, F., Macron, J. M., Jounieaux, V., & Duron, B. (1991) · Respiration Physiology · doi:10.1016/0034-5687(91)90010-g · Cited by 70 · cited 2×
“Animal studies suggest the presence of cold receptors in the nasal mucosa (12, 20), and the existence of nasal osmoreceptors is evoked in humans (19).”
BackgroundOn vagal bronchoconstriction in asthmatic patients by nasal irritation.
Nolte, D., & Berger, D. (1983) · PubMed · Cited by 67
Changes in activity of vagal bronchopulmonary C fibres by chemical and physical stimuli in the cat.
Delpierre, S., Grimaud, C., Jammes, Y., & Mei, N. (1981) · The Journal of Physiology · doi:10.1113/jphysiol.1981.sp013772 · Cited by 55 · cited 1×
“It has been previously shown in cats that cold-sensitive units were present in the superior laryngeal nerve innervating the larynx and the cervical trachea (7), but these receptors were not found in pulmonary vagal branches innervating intrapulmonary airways (3).”
BackgroundSelf-citation
Cited by
Research in high flow therapy: Mechanisms of action
Dysart, K., Miller, T. L., Wolfson, M. R., & Shaffer, T. H. (2009) · Respiratory Medicine · doi:10.1016/j.rmed.2009.04.007 · Cited by 742
Nishimura, M. (2016) · Respiratory Care · doi:10.4187/respcare.04577 · Cited by 476
Rhinitis and asthma: Evidence for respiratory system integration
Togias, A. (2003) · Journal of Allergy and Clinical Immunology · doi:10.1067/mai.2003.1592 · Cited by 471
Nguyen, J. L., Schwartz, J., & Dockery, D. W. (2014) · Indoor Air · doi:10.1111/ina.12052 · Cited by 410
“In fact, increasing the water vapor content in inspired gas has the same biophysical consequences as warming of the airway mucosa (Fontanari et al., 1996).”
BackgroundHigh-flow nasal cannula oxygen therapy in adults
Nishimura, M. (2015) · Journal of Intensive Care · doi:10.1186/s40560-015-0084-5 · Cited by 332
Allergic rhinobronchitis: The asthma–allergic rhinitis link
Simons, F. E. R. (1999) · Journal of Allergy and Clinical Immunology · doi:10.1016/s0091-6749(99)70320-9 · Cited by 289
United airway disease: current perspectives
Giavina-Bianchi, P., Aun, M., Takejima, P., Kalil, J., & Agondi, R. (2016) · Journal of Asthma and Allergy · doi:10.2147/jaa.s81541 · Cited by 247
“35,36 Another important study showed an increase in AHR after a nasal allergen provocation in asthmatics who had reported worsening of asthma symptoms following seasonal exacerbations of rhinitis.”
Reflex regulation of airway smooth muscle tone
Canning, B. J. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00313.2006 · Cited by 246
“Extrapulmonary afferents, including vagal afferents innervating the heart, arterial baroreceptors and chemoreceptors, esophagus and larynx, and nonvagal afferents innervating the upper airways, nose, and perhaps the face can also initiate reflex bronchospasm upon activation (20, 42, 43, 50, 65, 66, 102, 108, 117, 123,…”
BackgroundThe role of the nervous system in rhinitis
Sarin, S., Undem, B., Sanico, A., & Togias, A. (2006) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2006.09.013 · Cited by 245
Burgess, J. A., Walters, E. H., Byrnes, G. B., Matheson, M. C., Jenkins, M. A., Wharton, C. L., Johns, D. P., Abramson, M. J., Hopper, J. L., & Dharmage, S. C. (2007) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2007.07.020 · Cited by 239
Rhinitis therapy and the prevention of hospital care for asthma
Corren, J., Manning, B. E., Thompson, S. F., Hennessy, S., & Strom, B. L. (2004) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2003.11.034 · Cited by 213
for the Spanish Multidisciplinary Group of High Flow Supportive Therapy in Adults (HiSpaFlow), Roca, O., Hernández, G., Díaz-Lobato, S., Carratalá, J. M., Gutiérrez, R. M., & Masclans, J. R. (2016) · Critical Care · doi:10.1186/s13054-016-1263-z · Cited by 210
“In fact, while it has been shown that airway resistance increases during nasal breathing of room air at 24 °C in 12 healthy subjects, no changes were observed during inhalation of moist air [20].”
BackgroundPhysiologic Effects of High-Flow Nasal Cannula Oxygen in Critical Care Subjects
Vargas, F., Saint-Leger, M., Boyer, A., Bui, N. H., & Hilbert, G. (2015) · Respiratory Care · doi:10.4187/respcare.03814 · Cited by 199
“The difference between HFNC and CPAP was not significant (23 [18–25] breaths/min versus 21 [21–32] breaths/min, P .”
BackgroundThe nose-lung interaction in allergic rhinitis and asthma: united airways disease
Passalacqua, G., Ciprandi, G., & Canonica, G. W. (2001) · Current Opinion in Allergy and Clinical Immunology · doi:10.1097/00130832-200102000-00003 · Cited by 195
Cuquemelle, E., Pham, T., Papon, J.-F., Louis, B., Danin, P.-E., & Brochard, L. (2012) · Respiratory Care · doi:10.4187/respcare.01681 · Cited by 182
Perceiving Nasal Patency through Mucosal Cooling Rather than Air Temperature or Nasal Resistance
Zhao, K., Blacker, K., Luo, Y., Bryant, B., & Jiang, J. (2011) · PLoS ONE · doi:10.1371/journal.pone.0024618 · Cited by 151
“Previous studies [10] have suggested that prolonged exposure to either colder or hotter environment would change nasal volume and submucosal blood circulation, presumably due to sympathetic nervous system activation.”
BackgroundThomas, M., Kocevar, V. S., Zhang, Q., Yin, D. D., & Price, D. (2005) · Pediatrics · doi:10.1542/peds.2004-0067 · Cited by 145
Krouse, J. H., Brown, R. W., Fineman, S. M., Han, J. K., Heller, A. J., Joe, S., Krouse, H. J., Pillsbury, H. C., Ryan, M. W., & Veling, M. C. (2007) · Otolaryngology–Head and Neck Surgery · doi:10.1016/j.otohns.2007.02.019 · Cited by 132
Surgery of the turbinates and “empty nose” syndrome
Scheithauer, M. O. (2010) · German Medical Science GMS Publishing House · doi:10.3205/cto000067 · Cited by 121
“The existence of a naso-pulmonary reflex was first suspected in asthmatics and patients suffering from rhinitis [226].”
BackgroundSystemic immunologic and inflammatory aspects of allergic rhinitis
Togias, A. G. (2000) · Journal of Allergy and Clinical Immunology · doi:10.1067/mai.2000.110157 · Cited by 114
Systemic effects of local allergic disease
Togias, A. (2004) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2003.09.051 · Cited by 102
Metadata
- Authors
- Fontanari, P., Burnet, H., Zattara-Hartmann, M. C., & Jammes, Y.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1996-10-01
- Volume
- 81
- Issue
- 4
- Pages
- 1739-1743
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1854847211
- Cited by
- 239
- References
- 12
- FWCI
- 4.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.