Schoffelen, Paul F. M., Klaas R. Westerterp, Wim H. M. Saris, and Foppe Ten Hoor. A dual-respiration chamber system with automated calibration. J. Appl. Physiol. 83(6): 2064–2072, 1997.—This study characterizes respiration chambers with fully automated calibration. The system consists of two 14-m 3 pull-type chambers. Care was taken to provide a friendly environment for the subjects, with the possibility of social contact during the experiment. Gas analysis was automated to correct for analyzer drift and barometric pressure variations and to provide ease of use. Methods used for checking the system’s performance are described. The gas-analysis repeatability was within 0.002%. Results of alcohol combustion (50–350 ml/min CO 2) show an accuracy of 0.5 ± 2.0 (SD) % for O 2 consumption and −0.3 ± 1.6% for CO 2 production for 2- to 24-h experiments. It is concluded that response time is not the main factor with respect to the smallest practical measurement interval (duration); volume, mixing, gas-analysis accuracy, and levels of O 2 consumption and CO 2 production are at least equally important. The smallest practical interval was 15–25 min, as also found with most chamber systems described in the literature. We chose to standardize 0.5 h as the minimum measurement interval.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Determinants of 24-hour energy expenditure in man. Methods and results using a respiratory chamber.
Ravussin, E., Lillioja, S., Anderson, T. E., Christin, L., & Bogardus, C. (1986) · Journal of Clinical Investigation · doi:10.1172/jci112749 · Cited by 1,166
Cited by
Timmers, S., Konings, E., Bilet, L., Houtkooper, R. H., van de Weijer, T., Goossens, G. H., Hoeks, J., van der Krieken, S., Ryu, D., Kersten, S., et al. (2011) · Cell Metabolism · doi:10.1016/j.cmet.2011.10.002 · Cited by 1,320
van Can, J., Sloth, B., Jensen, C. B., Flint, A., Blaak, E. E., & Saris, W. H. M. (2014) · International Journal of Obesity · doi:10.1038/ijo.2013.162 · Cited by 537
Self-citationDirks, M. L., Wall, B. T., van de Valk, B., Holloway, T. M., Holloway, G. P., Chabowski, A., Goossens, G. H., & van Loon, L. J. C. (2016) · Diabetes · doi:10.2337/db15-1661 · Cited by 391
Lejeune, M. P., Westerterp, K. R., Adam, T. C., Luscombe-Marsh, N. D., & Westerterp-Plantenga, M. S. (2006) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/83.1.89 · Cited by 363
Self-citationReijnders, D., Goossens, G. H., Hermes, G. D. A., Neis, E. P. J. G., van der Beek, C. M., Most, J., Holst, J. J., Lenaerts, K., Kootte, R. S., Nieuwdorp, M., et al. (2016) · Cell Metabolism · doi:10.1016/j.cmet.2016.06.016 · Cited by 348
Metadata
- Authors
- Schoffelen, P. F. M., Westerterp, K. R., Saris, W. H. M., & Ten Hoor, F.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1997-12-01
- Volume
- 83
- Issue
- 6
- Pages
- 2064-2072
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2168684133
- Cited by
- 252
- References
- 1
- FWCI
- 4.62
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A dual-respiration chamber system with automated calibration. https://app.cochat.ai/papers/10.1152/jappl.1997.83.6.2064
- The paper
- Schoffelen, P. F. M., Westerterp, K. R., Saris, W. H. M., & Ten Hoor, F. (1997). A dual-respiration chamber system with automated calibration. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1997.83.6.2064
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.