The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Increased levels of circulating ICAM-1, VCAM-1, and L-selectin in obstructive sleep apnea syndrome
Abstract
Obstructive sleep apnea syndrome (OSAS) may be one of the most important risk factors of cardiovascular disorders, although the exact mechanism remains to be elucidated. In the present study, we hypothesized that OSAS-induced hypoxic stress might be involved in the etiology of cardiovascular disorders by activating adhesion molecules, including intercellular adhesion molecule 1 (ICAM-1), vascular cell adhesion molecule 1 (VCAM-1), and L-selectin. To examine this hypothesis, we measured circulating ICAM-1, VCAM-1, and L-selectin levels before and after sleep in OSAS patients and age-matched controls. The circulating ICAM-1, VCAM-1, and L-selectin levels increased in the OSAS patients before sleep compared with the normal subjects (ICAM-1: 392.9 ± 48.5 vs. 201.2 ± 55.0 ng/ml, P < 0.05; VCAM-1: 811.0 ± 87.8 vs. 574.2 ± 42.7 ng/ml, P < 0.05; L-selectin: 1,386.6 ± 77.9 vs. 1,038.8 ± 78.6 ng/ml, P< 0.01, respectively). After sleep, significantly greater levels of ICAM-1 and L-selectin, but not VCAM-1, were observed in the OSAS group. These observations suggest that OSAS-induced hypoxia activates adhesion molecules, resulting in the important risk factor of cardiovascular disorders. Treatment of OSAS can be, therefore, a potential approach to prevention of cardiovascular events.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adhesion receptors of the immune system
Springer, T. A. (1990) · Nature · doi:10.1038/346425a0 · Cited by 6,477
Marlin, S. D., & Springer, T. A. (1987) · Cell · doi:10.1016/0092-8674(87)90104-8 · Cited by 1,674
Mortality and Apnea Index in Obstructive Sleep Apnea
He, J., Kryger, M. H., Zorick, F. J., Conway, W., & Roth, T. (1988) · Chest · doi:10.1378/chest.94.1.9 · Cited by 1,514
Ridker, P. M., Hennekens, C. H., Roitman-Johnson, B., Stampfer, M. J., & Allen, J. (1998) · The Lancet · doi:10.1016/s0140-6736(97)09032-6 · Cited by 1,229 · cited 1×
“Moreover, the circulating ICAM-1 level may indicate a risk of future myocardial infarction, suggesting that antiadhesion therapies can be considered as a novel therapeutic means to treat cardiovascular disease (22).”
BackgroundAssociation of sleep apnoea with myocardial infarction in men
Hung, J., Whitford, E. G., Hillman, D. R., & Parsons, R. W. (1990) · The Lancet · doi:10.1016/0140-6736(90)91799-g · Cited by 907
Intercellular Adhesion Molecule-1 (ICAM-1) in the Pathogenesis of asthma
Wegner, C. D., Gundel, R. H., Reilly, P., Haynes, N., Letts, L. G., & Rothlein, R. (1990) · Science · doi:10.1126/science.1967851 · Cited by 898
A form of circulating ICAM-1 in human serum
Rothlein, R., Mainolfi, E. A., Czajkowski, M., & Marlin, S. D. (1991) · The Journal of Immunology · doi:10.4049/jimmunol.147.11.3788 · Cited by 678
Long-term Outcome for Obstructive Sleep Apnea Syndrome Patients
Partinen, M., Jamieson, A., & Guilleminault, C. (1988) · Chest · doi:10.1378/chest.94.6.1200 · Cited by 661
Smith, C. W., Rothlein, R., Hughes, B. J., Mariscalco, M. M., Rudloff, H. E., Schmalstieg, F. C., & Anderson, D. C. (1988) · Journal of Clinical Investigation · doi:10.1172/jci113788 · Cited by 599
Soluble L-selectin is present in human plasma at high levels and retains functional activity.
Schleiffenbaum, B., Spertini, O., & Tedder, T. F. (1992) · The Journal of cell biology · doi:10.1083/jcb.119.1.229 · Cited by 408
Cited by
Free Radicals in the Physiological Control of Cell Function
Dröge, W. (2002) · Physiological Reviews · doi:10.1152/physrev.00018.2001 · Cited by 9,855
Obstructive Sleep Apnea: Implications for Cardiac and Vascular Disease
Shamsuzzaman, A. S. M., Gersh, B. J., & Somers, V. K. (2003) · JAMA · doi:10.1001/jama.290.14.1906 · Cited by 1,188
Obstructive sleep apnoea syndrome – an oxidative stress disorder
Lavie, L. (2003) · Sleep Medicine Reviews · doi:10.1053/smrv.2002.0261 · Cited by 993
Ryan, S., Taylor, C. T., & McNicholas, W. T. (2005) · Circulation · doi:10.1161/circulationaha.105.556746 · Cited by 970
McNicholas, W. T., Bonsignore, M. R., & the Management Committee of EU COST ACTION B26 (2007) · European Respiratory Journal · doi:10.1183/09031936.00027406 · Cited by 911
Metadata
- Authors
- Ohga, E., Nagase, T., Tomita, T., Teramoto, S., Matsuse, T., Katayama, H., & Ouchi, Y.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1999-07-01
- Volume
- 87
- Issue
- 1
- Pages
- 10-14
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1888630264
- Cited by
- 266
- References
- 26
- FWCI
- 1.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Increased levels of circulating ICAM-1, VCAM-1, and L-selectin in obstructive sleep apnea syndrome. https://app.cochat.ai/papers/10.1152/jappl.1999.87.1.10
- The paper
- Ohga, E., Nagase, T., Tomita, T., Teramoto, S., Matsuse, T., Katayama, H., & Ouchi, Y. (1999). Increased levels of circulating ICAM-1, VCAM-1, and L-selectin in obstructive sleep apnea syndrome. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1999.87.1.10
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.