The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Reliability and validity of body composition measures in female athletes
Abstract
The purpose of this investigation was to determine the reliability and validity of bioelectrical impedance (BIA) and near-infrared interactance (NIR) for estimating body composition in female athletes. Dual-energy X-ray absorptiometry was used as the criterion measure for fat-free mass (FFM). Studies were performed in 132 athletes [age = 20.4 ± 1.5 (SD) yr]. Intraclass reliabilities (repeat and single trial) were 0.987–0.997 for BIA (resistance and reactance) and 0.957–0.980 for NIR (optical densities). Validity of BIA and NIR was assessed by double cross-validation. Because correlations were high ( r = 0.969–0.983) and prediction errors low, a single equation was developed by using all 132 subjects for both BIA and NIR. Also, an equation was developed for all subjects by using height and weight only. Results from dual-energy X-ray absorptiometry analysis showed FFM = 49.5 ± 6.0 kg, which corresponded to %body fat (%BF) of 20.4 ± 3.1%. BIA predicted FFM at 49.4 ± 5.9 kg ( r = 0.981, SEE = 1.1), and NIR prediction was 49.5 ± 5.8 kg ( r = 0.975, SEE = 1.2). Height and weight alone predicted FFM at 49.4 ± 5.7 kg ( r = 0.961, SEE = 1.6). When converted to %BF, prediction errors were ∼1.8% for BIA and NIR and 2.9% for height and weight. Results showed BIA and NIR to be extremely reliable and valid techniques for estimating body composition in college-age female athletes.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Concerns with applicability were high in 19 studies [37, 42–59] and unclear [41, 50, 60–69] in 12 studies due to the restricted sample size.”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [62]
In the citing paper
“One study was conducted on USA collegiate female athletes from different sports [62], one on Greek elite female dancers [51], and two studies on elite male soccer players in Taiwan [88] and Italy [31].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [62]
In the citing paper
“Considering the foot to hand technology, 12 equations are suitable for male [31, 39, 48, 69, 84, 85, 87, 104] and eight for female people only [39, 51, 62, 69, 87, 104].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [62]
In the citing paper
“Regarding foot to hand technology, we found an equation for estimating FM in males [48], five equations for estimating FFM in males [31, 69, 84, 85, 104], and four in females only [51, 62, 69, 104].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [62]
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Multiple regression in behavioral research
Kerlinger, F. N., & Pedhazur, E. J. (1973) · Medical Entomology and Zoology · Cited by 4,919
(1982) · Cited by 3,737
Assessment of fat-free mass using bioelectrical impedance measurements of the human body
Lukaski, H., Johnson, P., Bolonchuk, W., & Lykken, G. (1985) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/41.4.810 · Cited by 1,896
The Gross Composition of the Body
Siri, W. E. (1956) · Advances in biological and medical physics · doi:10.1016/b978-1-4832-3110-5.50011-x · Cited by 1,773
Mazess, R., Barden, H. S., Bisek, J., & Hanson, J. (1990) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/51.6.1106 · Cited by 1,465
Lean body mass estimation by bioelectrical impedance analysis: a four-site cross-validation study
Segal, K., Van Loan, M., Fitzgerald, P., Hodgdon, A., & Van Itallie, T. (1988) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/47.1.7 · Cited by 881
Estimation of total body water by bioelectrical impedance analysis
Kushner, R., & Schoeller, D. (1986) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/44.3.417 · Cited by 772
Pace, N., & Rathbun, E. N. (1945) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)51345-x · Cited by 757
Applied body composition assessment
(1996) · Choice Reviews Online · doi:10.5860/choice.34-0910 · Cited by 669
Bioelectrical impedance analysis: a review of principles and applications.
Kushner, R. (1992) · Journal of the American College of Nutrition · doi:10.1080/07315724.1992.12098245 · Cited by 666
Skinfolds and body density and their relation to body fatness: a review.
Tg, L. (1981) · PubMed · Cited by 663
Advances in Body Composition Assessment
Lohman, T. G. (1993) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199306000-00021 · Cited by 641
Dual-energy X-ray absorptiometry body composition model: review of physical concepts
Pietrobelli, A., Formica, C., Wang, Z., & Heymsfield, S. B. (1996) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1996.271.6.e941 · Cited by 594
Correlation of whole-body impedance with total body water volume.
Hoffer, E. C., Meador, C. K., & Simpson, D. C. (1969) · Journal of Applied Physiology · doi:10.1152/jappl.1969.27.4.531 · Cited by 530
Accuracy of measurements of body composition by dual-energy x-ray absorptiometry in vivo
Svendsen, O. L., Haarbo, J., Hassager, C., & Christiansen, C. (1993) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/57.5.605 · Cited by 408
Robinson, T. L., Snow-Harter, C., Taaffe, D. R., Gillis, D., Shaw, J. M., & Marcus, R. (1995) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650100107 · Cited by 325
In vivo validation of whole body composition estimates from dual-energy X-ray absorptiometry
Prior, B. M., Cureton, K. J., Modlesky, C. M., Evans, E. M., Sloniger, M. A., Saunders, M., & Lewis, R. D. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.83.2.623 · Cited by 317
A new approach for the estimation of body composition: infrared interactance
Conway, J., Norris, K., & Bodwell, C. E. (1984) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/40.6.1123 · Cited by 314
Reliability and validity of bioelectrical impedance in determining body composition
Jackson, A. S., Pollock, M. L., GRAVES, J. E., & Mahar, M. T. (1988) · Journal of Applied Physiology · doi:10.1152/jappl.1988.64.2.529 · Cited by 306
Pace, N., Kline, L., Schachman, H. K., & Harfenist, M. (1947) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(17)30906-7 · Cited by 238
Relative body fat and anthropometric prediction of body density of female athletes
Withers, R. T., Whittingham, N. O., Norton, K. I., Laforgia, J., Ellis, M. W., & Crockett, A. J. (1987) · European Journal of Applied Physiology · doi:10.1007/bf00640641 · Cited by 230
The Female Athlete Triad: The Inter-Relatedness of Disordered Eating, Amenorrhea, and Osteoporosis
Nattiv, A., Agostini, R., Drinkwater, B. L., & Yeager, K. K. (1994) · Clinics in Sports Medicine · doi:10.1016/s0278-5919(20)30338-0 · Cited by 218
Detection of small changes in body composition by dual-energy x-ray absorptiometry
Going, S., Massett, M. P., Hall, M., Bare, L., Root, P. A., Williams, D., & Lohman, T. (1993) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/57.6.845 · Cited by 210
Preliminary evidence that DEXA provides an accurate assessment of body composition
Kohrt, W. M. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.84.1.372 · Cited by 186
Body fat from body density: underwater weighing vs. dual-photon absorptiometry
Wang, J., Heymsfield, S. B., Aulet, M., Thornton, J. C., & Pierson, R. N. (1989) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1989.256.6.e829 · Cited by 115
Bone mineral density and dietary intake of female college gymnasts
KIRCHNER, E. M., Lewis, R. D., & CONNOR, P. J. O. (1995) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199504000-00012 · Cited by 108
Research progress in validation of laboratory methods of assessing body composition
Lohman, T. G. (1984) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198412000-00014 · Cited by 81
Physiologic Considerations for Women in Sport
Sanborn, C. F., & Jankowski, C. M. (1994) · Clinics in Sports Medicine · doi:10.1016/s0278-5919(20)30332-x · Cited by 55
The female triad: Eating Disorders, Amenorrhea, and Osteoporosis
Putukian, M. (1994) · Medical Clinics of North America · doi:10.1016/s0025-7125(16)30163-8 · Cited by 54
Validity of “Generalized” Equations for Body Composition Analysis in Women Athletes
Sinning, W. E., & Wilson, J. R. (1984) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.1984.10608392 · Cited by 53
Prediction of body composition in premenopausal females from dual-energy X-ray absorptiometry
Hansen, N. J., Lohman, T. G., Going, S. B., Hall, M. C., Pamenter, R. W., Bare, L. A., Boyden, T. W., & HOUTKOOPER, L. B. (1993) · Journal of Applied Physiology · doi:10.1152/jappl.1993.75.4.1637 · Cited by 52
Lukaski, H. C., & Bolonchuk, W. W. (1987) · Cited by 52
Bonacich, P. (1997) · Rationality and Society · doi:10.1177/104346397009003006 · Cited by 48
SKINFOLD DISTRIBUTIONS IN MIDDLE‐AGED AMERICAN MEN: A CONTRIBUTION TO NORMS OF LEANNESS‐FATNESS*
Brožek, J., Kihlberg, J. K., TAYLOR, H. L., & Keys, A. B. (1963) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1963.tb15776.x · Cited by 47
ANTHROPOMETRIC ESTIMATION OF BODY DENSITY AND LEAN BODY WEIGHT IN WOMEN GYMNASTS
Sinning, W. E. (1976) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-197621000-00065 · Cited by 45
Body composition by x-ray absorptiometry and bioelectrical impedance in female runners
Pichard, C., Kyle, U. G., Gremion, G., Gerbase, M. W., & Slosman, D. O. (1997) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199711000-00021 · Cited by 44
Variation in bone mineral content and estimated body fat in young adult females
Bunt, J. C., Going, S. B., Lohman, T. G., HEINRICH, C. H., PERRY, C. D., & Pamenter, R. W. (1990) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199010000-00004 · Cited by 40
Schreiner, P. J., Pitäniemi, J., Pekkanen, J., & Salomaa, V. V. (1995) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(95)00052-6 · Cited by 37
Dual-photon absorptiometry (spine mineral content measurement)
Mazess, R. B., Peppler, W., Madsen, M. T., & Wilson, C. R. (1983) · Physics in Medicine and Biology · doi:10.1088/0031-9155/28/6/016 · Cited by 33
Body Composition and Menstrual Function in Athletes
Sinning, W. E., & Little, K. D. (1987) · Sports Medicine · doi:10.2165/00007256-198704010-00004 · Cited by 32
Body Composition of Elite Female Distance Runners*
Graves, J., Pollock, M. L., & Sparling, P. B. (1987) · International Journal of Sports Medicine · doi:10.1055/s-2008-1025713 · Cited by 30
Smith, A. D. (1996) · The Physician and Sportsmedicine · doi:10.3810/psm.1996.07.1407 · Cited by 26
Hortobágyi, T., Israel, R. G., Houmard, J. A., McCammon, M. R., & O'Brien, K. F. (1992) · PubMed · Cited by 23
Relationship of Optical Density and Skinfold Measurements: Effects of Age and Level of Body Fatness
Quatrochi, J. A., Hicks, V. L., Heyward, V. H., Colville, B. C., Cook, K. L., Jenkins, K. A., & Wilson, W. L. (1992) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.1992.10608762 · Cited by 9
HOUTKOOPER, L. B., Going, S. B., Westfall, C. H., & Lohman, T. G. (1980) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198004001-00229 · Cited by 6
HOUTKOOPER, L. B., Going, S. B., Westfall, C. H., & Lohman, T. G. (1989) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198904001-00229 · Cited by 6
Research works printed but not linked: 6
- Hortobagyi T., 1992, Eur. J. Clin. Nutr., 46, 205
- Houtkooper L. B., 1994, Sports Sci. Exchange, 7, 116
- Lohman T. G., 1981, Human Biol., 53, 181
- Pietrobelli A., 1996, Am. J. Physiol., 271, E941
- Sinning W. E., 1978, Med. Sci. Sports Exerc., 10, 243
- Wang J., 1989, Am. J. Physiol., 256, E829
Cited by
Sorted by citations
Endocrine Control of Body Composition in Infancy, Childhood, and Puberty
Veldhuis, J. D., Roemmich, J. N., Richmond, E. J., Rogol, A. D., Lovejoy, J. C., Sheffield-Moore, M., Mauras, N., & Bowers, C. Y. (2005) · Endocrine Reviews · doi:10.1210/er.2003-0038 · Cited by 452
Marfell-Jones, M., Stewart, A., & Olds, T. (2006) · Routledge eBooks · doi:10.4324/9780203970157 · Cited by 262
Moon, J. R. (2013) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2012.165 · Cited by 237
Reliability and Validity of Commercially Available Low-Cost Bioelectrical Impedance Analysis
Vasold, K. L., Parks, A. C., Phelan, D. M. L., Pontifex, M. B., & Pivarnik, J. M. (2018) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.2018-0283 · Cited by 175
Self-citationThe accuracy and precision of DXA for assessing body composition in team sport athletes
Bilsborough, J. C., Greenway, K., Opar, D. A., Livingstone, S. G., Cordy, J. T., & Coutts, A. J. (2014) · Journal of Sports Sciences · doi:10.1080/02640414.2014.926380 · Cited by 171
Metadata
- Authors
- Fornetti, W. C., Pivarnik, J. M., Foley, J. M., & Fiechtner, J. J.
- Affiliations
- Departments of Kinesiology and
- Michigan State University (US)
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1999-09-01
- Volume
- 87
- Issue
- 3
- Pages
- 1114-1122
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1961927277
- Cited by
- 120
- References
- 47
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 3 · 2023: 3 · 2022: 3 · 2021: 6 · 2020: 3 · 2019: 6 · 2018: 9 · 2017: 6 · 2016: 3 · 2015: 6 · 2014: 3 · 2013: 8 · 2012: 9
- FWCI
- 0.57
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Applied Physiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Body Composition Measurement Techniques
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Physical Education and Training Studies
- Keywords
- body composition, bioelectrical impedance analysis, near-infrared interactance, fat-free mass, body fat percentage, female athletes, measurement reliability, method validity, dual-energy X-ray absorptiometry, college athletes
- MeSH terms
- Adolescent, Adult, Body Composition, Data Collection, Female, Humans, Sports, Reproducibility of Results, Absorptiometry, Photon, Electric Impedance, Spectroscopy, Near-Infrared
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review