The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Improved analysis of brachial artery ultrasound using a novel edge-detection software system
Abstract
Brachial artery ultrasound is commonly employed for noninvasive assessment of endothelial function. However, analysis is observer dependent and susceptible to errors. We describe studies on a computerized edge-detection and wall-tracking software program to allow more accurate and reproducible measurement. In study 1, three purpose-built Perspex phantom arteries, 3.00, 4.00, and 6.00 mm in diameter, were measured with the software. There was a mean bias of 11 μm ( P < 0.001 at each level) between known and measured values; the mean resolving power of the software was estimated as 8.3 μm. In study 2, the mean intraobserver coefficient of variation of repeated measures of flow-mediated dilation (FMD) using the software (6.7%) was significantly lower than that for traditional manual measurements using the intima-lumen interfaces (24.8%, P < 0.05) and intima-media interfaces (32.5%, P < 0.05). In study 3, 24 healthy volunteers underwent repeat testing twice within 1 wk; the coefficients of variation for between-visit reproducibility of FMD and response to glyceryl trinitrate using the software were 14.7 and 17.6%, respectively. Assuming 80% power and an α of 0.05, eight subjects with matched controls would be required, in a parallel designed study, to detect an absolute 2.5% change in FMD. In summary, we have developed a semiautomated computerized vascular ultrasound analysis system that will improve the power of clinical intervention studies to detect small changes in arterial diameter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Non-invasive detection of endothelial dysfunction in children and adults at risk of atherosclerosis
Celermajer, D. S., Sorensen, K. E., Gooch, V. M., Spiegelhalter, D. J., Miller, O. I., Sullivan, I. D., Lloyd, J. K., & Deanfield, J. E. (1992) · The Lancet · doi:10.1016/0140-6736(92)93147-f · Cited by 4,742
Schächinger, V., Britten, M. B., & Zeiher, A. M. (2000) · Circulation · doi:10.1161/01.cir.101.16.1899 · Cited by 2,585
Power and sample size calculations
Dupont, W. D., & Plummer, W. D. (1990) · Controlled Clinical Trials · doi:10.1016/0197-2456(90)90005-m · Cited by 2,092
Long-Term Follow-Up of Patients With Mild Coronary Artery Disease and Endothelial Dysfunction
Suwaidi, J. A., Hamasaki, S., Higano, S. T., Nishimura, R. A., Holmes, D. R., & Lerman, A. (2000) · Circulation · doi:10.1161/01.cir.101.9.948 · Cited by 2,043
Close Relation of Endothelial Function in the Human Coronary and Peripheral Circulations
Anderson, T. J., Uehata, A., Gerhard, M. D., Meredith, I. T., Knab, S., Delagrange, D., Lieberman, E. H., Ganz, P., Creager, M. A., Yeung, A. C., et al. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00327-4 · Cited by 2,033 · cited 1×
“Brachial arterial flow-mediated dilation (FMD), assessed by high-resolution ultrasound, reflects endothelium-dependent vasodilator function (4), which may be used as a surrogate for function of the coronary circulation (2).”
BackgroundCelermajer, D. S., Sorensen, K. E., Bull, C., Robinson, J., & Deanfield, J. E. (1994) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)90141-4 · Cited by 1,229
Statistical Methods in Epidemiology
(2012) · SpringerReference · doi:10.1007/springerreference_205629 · Cited by 1,124
Simvastatin, an HMG–Coenzyme A Reductase Inhibitor, Improves Endothelial Function Within 1 Month
O'Driscoll, G., Green, D., & Taylor, R. R. (1997) · Circulation · doi:10.1161/01.cir.95.5.1126 · Cited by 952
Self-citationMcVeigh, G. E., Brennan, G. M., Johnston, G. D., McDermott, B. J., McGrath, L. T., Henry, W. R., Andrews, J. W., & Hayes, J. R. (1992) · Diabetologia · doi:10.1007/bf00429099 · Cited by 916
Sorensen, K. E., Celermajer, D. S., Spiegelhalter, D. J., Georgakopoulos, D., Robinson, J., Thomas, O., & Deanfield, J. E. (1995) · Heart · doi:10.1136/hrt.74.3.247 · Cited by 694
Late prognostic value of flow-mediated dilation in the brachial artery of patients with chest pain
Neunteufl, T., Heher, S., Katzenschlager, R., Wölfl, G., Kostner, K., Maurer, G., & Weidinger, F. (2000) · The American Journal of Cardiology · doi:10.1016/s0002-9149(00)00857-2 · Cited by 554
Endothelial function in chronic congestive heart failure
Drexler, H., Hayoz, D., Münzel, T., Hornig, B., Just, H., Brunner, H. R., & Zelis, R. (1992) · The American Journal of Cardiology · doi:10.1016/0002-9149(92)90710-g · Cited by 550
Wendelhag, I., Gustavsson, T., Suurküla, M., Berglund, G., & Wikstrand, J. (1991) · Clinical Physiology · doi:10.1111/j.1475-097x.1991.tb00676.x · Cited by 515
Reddy, K. G., Nair, R. N., Sheehan, H. M., & Hodgson, J. M. (1994) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)90627-0 · Cited by 447
Wendelhag, I., Liang, Q., Gustavsson, T., & Wikstrand, J. (1997) · Stroke · doi:10.1161/01.str.28.11.2195 · Cited by 375
A multiscale dynamic programming procedure for boundary detection in ultrasonic artery images
Liang, Q., Wendelhag, I., Wikstrand, J., & Gustavsson, T. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.836372 · Cited by 311
Selzer, R. H., Hodis, H. N., Kwong-Fu, H., Mack, W. J., Lee, P. L., Liu, C.-R., & Liu, C.-H. (1994) · Atherosclerosis · doi:10.1016/0021-9150(94)90186-4 · Cited by 300
Technical aspects of evaluating brachial artery vasodilatation using high-frequency ultrasound
Corretti, M. C., Plotnick, G. D., & Vogel, R. A. (1995) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1995.268.4.h1397 · Cited by 282
Endothelial Control of Arterial Distensibility Is Impaired in Chronic Heart Failure
Ramsey, M. W., Goodfellow, J., Jones, C. J. H., Luddington, L. A., Lewis, M. J., & Henderson, A. H. (1995) · Circulation · doi:10.1161/01.cir.92.11.3212 · Cited by 279
LIANG, Y.-L., TEEDE, H., KOTSOPOULOS, D., SHIEL, L., CAMERON, J. D., DART, A. M., & McGRATH, B. P. (1998) · Clinical Science · doi:10.1042/cs0950669 · Cited by 277
Effect of aerobic and resistance exercise training on vascular function in heart failure
Maiorana, A., O'Driscoll, G., Dembo, L., Cheetham, C., Goodman, C., Taylor, R., & Green, D. (2000) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2000.279.4.h1999 · Cited by 250
Self-citationKatz, S. D., Schwarz, M., Yuen, J., & LeJemtel, T. H. (1993) · Circulation · doi:10.1161/01.cir.88.1.55 · Cited by 227
O'Driscoll, G., Green, D., Rankin, J., Stanton, K., & Taylor, R. (1997) · Journal of Clinical Investigation · doi:10.1172/jci119580 · Cited by 218
Self-citationIs NO an endogenous antiatherogenic molecule?
Cooke, J. P., & Tsao, P. S. (1994) · Arteriosclerosis and Thrombosis: A Journal of Vascular Biology · doi:10.1161/01.atv.14.5.653 · Cited by 216
Watts, G. F., O'brien, S. F., Silvester, W., & Millar, J. A. (1996) · Clinical Science · doi:10.1042/cs0910567 · Cited by 205
Self-citationSchroeder, S., Enderle, M. D., Ossen, R., Meisner, C., Baumbach, A., Pfohl, M., Herdeg, C., Oberhoff, M., Haering, H. U., & Karsch, K. R. (1999) · American Heart Journal · doi:10.1016/s0002-8703(99)70189-4 · Cited by 204
Arterial Abnormalities in the Offspring of Patients with Premature Myocardial Infarction
Gaeta, G., De Michele, M., Cuomo, S., Guarini, P., Foglia, M. C., Bond, M. G., & Trevisan, M. (2000) · New England Journal of Medicine · doi:10.1056/nejm200009213431203 · Cited by 195
O’Driscoll, G., Green, D., Maiorana, A., Stanton, K., Colreavy, F., & Taylor, R. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00065-0 · Cited by 174
Self-citationNoninvasive Assessment of Endothelium-Dependent Flow-Mediated Dilation of the Brachial Artery
Uehata, A., Lieberman, E. H., Gerhard, M. D., Anderson, T. J., Ganz, P., Polak, J. F., Creager, M. A., & Yeung, A. C. (1997) · Vascular Medicine · doi:10.1177/1358863x9700200203 · Cited by 171
Kool, M. J. F., Merode, T. V., Reneman, R. S., et al. (1994) · Cardiovascular Research · doi:10.1093/cvr/28.5.610 · Cited by 145
Is NO an endogenous antiatherogenic molecule
PCooke, J., & STsao, P. (1994) · Arteriosclerosis and Thrombosis A Journal of Vascular Biology · Cited by 134
Endothelial vasodilator dysfunction: Pathogenetic link to myocardial ischaemia or epiphenomenon?
Zeiher, A. M. (1996) · The Lancet · doi:10.1016/s0140-6736(96)98004-6 · Cited by 107
New methods for arterial diameter measurement from B-mode images
Stadler, R. W., Karl, W. C., & Lees, R. S. (1996) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(95)02017-9 · Cited by 78
Hardie, K. L., Kinlay, S., Hardy, D. B., Wlodarczyk, J., Silberberg, J. S., & FLETCHER, P. J. (1997) · Australian and New Zealand Journal of Medicine · doi:10.1111/j.1445-5994.1997.tb00992.x · Cited by 73
Impaired acetylcholine-mediated vasodilation in patients with congestive heart failure.
Agmon, Y. (1994) · Circulation · doi:10.1161/circ.89.2.8313584 · Cited by 66
Shiran, A., Mintz, G., Leiboff, B., Kent, K., Pichard, A., Satler, L., Kimura, T., Nobuyoshi, M., & Leon, M. (1999) · American Journal of Cardiology · doi:10.1016/s0002-9149(99)00119-8 · Cited by 50
SPECIAL ARTICLE: NON‐INVASIVE MEASUREMENT OF ENDOTHELIAL FUNCTION
Playford, D. A., & Watts, G. F. (1998) · Clinical and Experimental Pharmacology and Physiology · doi:10.1111/j.1440-1681.1998.tb02269.x · Cited by 48
Self-citationIntracardiac echocardiography: computerized detection of left ventricular borders
Milan Sonka, A., Liang, W., Kanani, P. M., Allan, J. J., DeJong, S. C., Kerber, R. E., & McKay, C. R. (1998) · International journal of cardiac imaging · doi:10.1023/a:1006114907352 · Cited by 16
Cited by
Assessment of flow-mediated dilation in humans: a methodological and physiological guideline
Thijssen, D. H. J., Black, M. A., Pyke, K. E., Padilla, J., Atkinson, G., Harris, R. A., Parker, B., Widlansky, M. E., Tschakovsky, M. E., & Green, D. J. (2011) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00471.2010 · Cited by 1,483
Self-citationEffect of exercise training on endothelium‐derived nitric oxide function in humans
Green, D. J., Maiorana, A., O'Driscoll, G., & Taylor, R. (2004) · The Journal of Physiology · doi:10.1113/jphysiol.2004.068197 · Cited by 1,040
Self-citationThijssen, D. H. J., Bruno, R. M., van Mil, A. C. C. M., Holder, S. M., Faita, F., Greyling, A., Zock, P. L., Taddei, S., Deanfield, J. E., Luscher, T., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehz350 · Cited by 995
Self-citationPyke, K. E., & Tschakovsky, M. E. (2005) · The Journal of Physiology · doi:10.1113/jphysiol.2005.089755 · Cited by 614
Shear Stress Mediates Endothelial Adaptations to Exercise Training in Humans
Tinken, T. M., Thijssen, D. H. J., Hopkins, N., Dawson, E. A., Cable, N. T., & Green, D. J. (2010) · Hypertension · doi:10.1161/hypertensionaha.109.146282 · Cited by 493
Self-citation
Metadata
- Authors
- Woodman, R. J., Playford, D. A., Watts, G. F., Cheetham, C., Reed, C., Taylor, R. R., Puddey, I. B., Beilin, L. J., Burke, V., Mori, T. A., & Green, D.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2001-08-01
- Volume
- 91
- Issue
- 2
- Pages
- 929-937
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2103474165
- Cited by
- 533
- References
- 38
- FWCI
- 6.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.